== Well Details ==
 
== Well Details ==
 
{| class="wikitable welldetails" width="95%"
 
{| class="wikitable welldetails" width="95%"
 
| Well ID: 34-085-21220
 
| Well ID: 34-085-21220
−
| style="height=100%; align=center" rowspan="15" | {{#display_map: 41.68646524, -81.19668726 | width=100% | height=100% }}  
+
| style="height=100%; align=center" rowspan="17" | {{#display_map: 41.68, -81.19 | width=100% | height=100% }}
 
|-
 
|-
−
| County: [[Lake County, Ohio|Lake]]
+
| Country: United States
 
|-
 
|-
−
| Municipality:  
+
| State: Ohio
 +
|-
 +
| County: [[Lake_County,_Ohio|Lake]]
 +
|-
 +
| Municipality: [[Leroy_Township,_Lake_County,_Ohio|Leroy Township]]
 
|-
 
|-
 
| Operator Name: [[JOHN D OIL & GAS COMPANY]]
 
| Operator Name: [[JOHN D OIL & GAS COMPANY]]
Line 13: Line 17:
 
| Well Pad ID:  
 
| Well Pad ID:  
 
|-
 
|-
−
| Farm/Lease Name:  
+
| Farm/Lease Name: PASKAN
 
|-
 
|-
−
| First Permit Date:  
+
| License Status: Final Restoration
 
|-
 
|-
−
| Last Permit Date:  
+
| License Date: 2010-11-01
 
|-
 
|-
 
| Spud Date: 2007-05-15
 
| Spud Date: 2007-05-15
 
|-
 
|-
−
| Unconventional: No
+
| Spud Drilling Contractor: [[ROSS WELL SERVICE]]
 +
|-
 +
| Final Drill Date: 2007-05-23
 +
|-
 +
| Well Total Depth: 3450.00 ft
 
|-
 
|-
 
| Configuration: Vertical
 
| Configuration: Vertical
 
|-
 
|-
−
| Well Status: Plugged and Abandoned
+
| Latitude: 41.680000
 +
|-
 +
| Longitude: -81.190000
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title = Risk Based Data Management System - Well, tblLocational, tblPlugWell, tblInspection, tblCivilTownships and tblPad Tables
 +
|publisher = [[Ohio Department of Natural Resources]]
 +
| date =  2020-11-16
 +
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 +
| accessdate = 2020-11-16 }}</ref>
 +
== Well History ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Well Status
 +
!scope="col" style="width: 15%;text-align: center"| Well Status Date
 +
!scope="col" style="text-align: center"| Comment
 +
|-
 +
| APP
 +
| 2006-10-16
 +
| Proposed Formations:CLINTON, Issued Date:10/16/2006, Expired Date:10/16/2007 6:00:00 AM, Drilling unit acres:20.9, Proposed Well Type:OG, Proposed Well Class:POOL
 +
|-
 +
| Completed
 +
| 2007-05-23
 +
| 
 +
|-
 +
| Reached Total Depth
 +
| 2007-05-23
 +
| 
 +
|-
 +
| Completion Report Received
 +
| 2007-08-09
 +
| 
 +
|-
 +
| APP
 +
| 2008-06-26
 +
| Proposed Formations:CLINTON, Issued Date:6/26/2008, Expired Date:6/26/2009 6:00:00 AM, Drilling unit acres:0, Proposed Well Type:OG, Proposed Well Class:
 +
|-
 +
| Plugged Back
 +
| 2008-07-01
 +
| 
 +
|-
 +
| APP
 +
| 2008-07-29
 +
| Proposed Formations:OHIO SHALE, Issued Date:7/29/2008, Expired Date:7/29/2009 6:00:00 AM, Drilling unit acres:20.9, Proposed Well Type:OG, Proposed Well Class:ESPW
 +
|-
 +
| APP
 +
| 2010-11-01
 +
| Proposed Formations:OHIO SHALE, Issued Date:11/1/2010, Expired Date:10/31/2012 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:OG, Proposed Well Class:
 +
|-
 +
| Plugged/Abandoned
 +
| 2011-09-15
 +
| 
 +
|-
 +
| Construction Permit Expires
 +
| 2011-11-01
 +
| 
 +
|-
 +
| Record Last Modified
 +
| 2017-02-15
 +
| 
 +
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title = Risk Based Data Management System - Well and WellHistry Tables
 +
|publisher = [[Ohio Department of Natural Resources]]
 +
| date = 2020-11-16
 +
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 +
| accessdate = 2020-11-16 }}</ref>
 +
== Perforation Treatments ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Perforation Date
 +
!scope="col" style="text-align: center"| Interval Top (ft)
 +
!scope="col" style="text-align: center"| Interval Base (ft)
 +
!scope="col" style="text-align: center"| Number of Shots
 +
|-
 +
| 2007-11-05
 +
| style="text-align: right;" | 3229
 +
| style="text-align: right;" | 3284
 +
| style="text-align: right;" | 20
 +
|-
 +
|
 +
| style="text-align: right;" | 3229
 +
| style="text-align: right;" | 3284
 +
| style="text-align: right;" | 20
 +
|-
 +
|
 +
| style="text-align: right;" | 3229
 +
| style="text-align: right;" | 3284
 +
| style="text-align: right;" | 20
 +
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title = Risk Based Data Management System - Perfs Table
 +
|publisher = [[Ohio Department of Natural Resources]]
 +
| date =  2020-11-16
 +
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 +
| accessdate = 2020-11-16 }}</ref>
 +
<!--== Fracking Activities ==
 +
==== Fracking Jobs ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Job Number
 +
!scope="col" style="text-align: center"| Job Start Date
 +
!scope="col" style="text-align: center"| Job End Date
 +
!scope="col" style="text-align: center"| True Vertical Depth (ft)
 +
!scope="col" style="text-align: center"| Total Water Volume (gal)
 +
!scope="col" style="text-align: center"| Total Non-Water Volume (gal)
 
|-
 
|-
−
| Violations: 0
+
|}-->
 +
<!--==== Fluid Composition Data ====
 +
{| class="wikitable sortable" style="width: 100%"
 +
!scope="col" style="text-align: center"| Job Number
 +
!scope="col" style="text-align: center"| Trade Name
 +
!scope="col" style="text-align: center"| Supplier
 +
!scope="col" style="text-align: center"| Purpose
 +
!scope="col" style="text-align: center"| Ingredient Name
 +
!scope="col" style="white-space: nowrap;text-align: center"| CAS Number
 +
!scope="col" style="text-align: center"| Additive Percentage by Mass
 +
!scope="col" style="text-align: center"| Job Percentage by Mass
 +
!scope="col" style="text-align: center"| Mass Used (lb)
 
|-
 
|-
−
| Latitude: 41.68646524
+
|}-->
 +
== Stimulations Data ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Stimulation Date
 +
!scope="col" style="text-align: center"| Chemical Agent
 +
!scope="col" style="text-align: center"| Chemical Agent Concentration (%)
 +
!scope="col" style="text-align: center"| Fracking Fluid Volume
 +
!scope="col" style="text-align: center"| Mass of Proppant Used (lb)
 +
!scope="col" style="text-align: center"| Fracking Company
 +
!scope="col" style="text-align: center"| Comments
 
|-
 
|-
−
| Longitude: -81.19668726
+
|  
 +
| H2O
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 19321 Gal
 +
| style="text-align: right;" | 100000
 +
|
 +
| 585M SCF NITROGEN ASSIST
 
|-
 
|-
 
|}
 
|}
 +
For data sources see<ref>{{cite web
 +
| title = Risk Based Data Management System - tblStimulation Table
 +
|publisher = [[Ohio Department of Natural Resources]]
 +
| date =  2020-11-16
 +
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 +
| accessdate = 2020-11-16 }}</ref>
 +
<!--== Production Data ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Period
 +
!scope="col" style="text-align: center"| Operator Name
 +
!scope="col" style="text-align: center"| Gas Quantity (mcf)
 +
!scope="col" style="text-align: center"| Oil Quantity (bbl)
 +
!scope="col" style="text-align: center"| Production Days
 +
|-
 +
|}-->
 +
<!--== Waste Data ==
 +
{| class="wikitable sortable"
 +
!scope="col" style="text-align: center"| Period
 +
!scope="col" style="text-align: center"| Operator Name
 +
!scope="col" style="text-align: center"| Waste Type
 +
!scope="col" style="text-align: center"| Quantity (bbl)
 +
!scope="col" style="text-align: center"| Production Days
 +
|-
 +
|}-->
 
== Inspection Data ==
 
== Inspection Data ==
 +
==== Inspections Performed ====
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
−
!scope="col" | INSPECTION ID
+
!scope="col" style="text-align: center"| Inspection ID
−
!scope="col" | DATE
+
!scope="col" style="text-align: center"| Inspection Date
−
!scope="col" | DESCRIPTION
+
!scope="col" style="text-align: center"| Inspection Type
−
!scope="col" | COMMENT
+
!scope="col" style="text-align: center"| Inspection Result
−
!scope="col" | VIOLATION ID
+
!scope="col" style="text-align: center"| Inspection Comments
−
!scope="col" | VIOLATION CODE
 
−
!scope="col" | VIOLATION COMMENT
 
 
|-
 
|-
 
| -1200452686
 
| -1200452686
−
| 2008-07-01
+
| 2008-7-1 0:00:0
 +
| PB
 +
| No Violations
 +
|
 +
|-
 +
| -1701824481
 +
| 2016-8-25 0:00:
 +
| FR
 +
| No Violations
 +
| 1.00
 +
|-
 +
| -2116144893
 +
| 2010-9-1 0:00:0
 +
| UP
 +
| No Violations
 +
|
 +
|-
 +
| -2127347360
 +
| 2012-8-23 0:00:
 +
| FR
 +
| No Violations
 
|  
 
|  
−
| set lime plug
+
|-
 +
| -400703373
 +
| 2010-9-1 0:00:0
 +
| UP
 +
| No Violations
 
|  
 
|  
 +
|-
 +
| -626925179
 +
| 2014-5-16 0:00:
 +
| UP
 +
| No Violations
 
|  
 
|  
 +
|-
 +
| -709946149
 +
| 2007-5-22 0:00:
 +
| DD
 +
| No Violations
 
|  
 
|  
 
|-
 
|-
 +
| 0054405810
 +
| 2012-07-18
 +
| Administrative Inspection
 +
| No Violations
 +
| I was on the phone with Tim Reily from John D, discussing other wells.  I reminded Tim that I was still waiting on a Land Owner Waiver for the lease road on this site.  Tim indicated that the landowner will not sign a waiver.  The landowner was not being reasonable on the amount of final restoration work that they wanted completed.  I informed Tim if the landowner will not sign the waiver, the lease road needs to come out.  Tim advised me that they are short on man power at this time.  I advised Tim to keep working on the waiver.
 +
|-
 +
| 0348195268
 +
| 2007-05-16
 +
| Drill / Deepen /  Reopen
 +
| No Violations
 +
| drilling 260
 +
|-
 +
| 0400703373
 +
| 2010-09-01
 +
| UrbanProduction Wells
 +
| No Violations
 +
| FOLLOW UP TO NOV #  1997519457 FOLLOW UP TO NOV #  1283878592 The well was found shut in and disconnected.  Other than sections of flow line, all other equipment had been removed, including the tank battery.  There were two piles of topsoil remaining on location.
 +
 +
Post complete identification at the well.
 +
Plug or
 +
|-
 +
| 0626925179
 +
| 2014-05-16
 +
| UrbanProduction Wells
 +
| No Violations
 +
| The area formerly occupied by the drilling unit which had been later observed to be devoid of vegetation has been successfully graded and seeded. Other areas of adverse impact from the plugging opertations (e.g. deep ruts in the farm field area) have been re-graded and restored.
 +
|-
 +
| 0709946149
 +
| 2007-05-22
 +
| Drill / Deepen /  Reopen
 +
| No Violations
 +
|
 +
|-
 +
| 1200452686
 +
| 2008-07-01
 +
| Plug / Plug Back
 +
| No Violations
 +
| set lime plug
 
|-
 
|-
 
| 1283878592
 
| 1283878592
 
| 2010-09-01
 
| 2010-09-01
−
|  
+
| UrbanProduction Wells
 +
| Violations Noted
 
| The well was found shut in and disconnected.  Other than sections of flow line, all other equipment had been removed, including the tank battery.  There were two piles of topsoil remaining on location.
 
| The well was found shut in and disconnected.  Other than sections of flow line, all other equipment had been removed, including the tank battery.  There were two piles of topsoil remaining on location.
  
 
Post complete identification at the well.
 
Post complete identification at the well.
 
Plug or
 
Plug or
−
|
 
−
|
 
−
|
 
−
|-
 
 
|-
 
|-
 
| 1325684310
 
| 1325684310
 
| 2011-12-13
 
| 2011-12-13
−
|  
+
| Final Restoration
 +
| No Violations
 
| Final grading and seeding has been completed at this site.  Vegetation is starting to become established.  A land owner waiver will need to be submitted for the lease road, which remains intact.
 
| Final grading and seeding has been completed at this site.  Vegetation is starting to become established.  A land owner waiver will need to be submitted for the lease road, which remains intact.
−
|
 
−
|
 
−
|
 
−
|-
 
 
|-
 
|-
 
| 1345747096
 
| 1345747096
 
| 2012-08-23
 
| 2012-08-23
−
|  
+
| Final Restoration
 +
| Violations Noted
 
| I met with the land owner Joe Ann Tabor on location at 08:45 this morning.  I reviewed the location with the land owner and my inspection found the following.  The area affected from oil and gas production and plugging operations needs final grading and seeding completed on it.  The area of the pit is barren and needs Bio-remediation completed on it to establish vegetation. Bio-remediation will include liming and fertilizing as needed to establish vegetation.  I have attached a map to this report designating three areas as A, B and C that still need reclamation work.  Please see the attached map.  Area A requires: final grading and seeding needs to be completed on it.  Area B requires: redistribution of the topsoil,( there is a high area along the south edge of the pad that appears to be topsoil.) This high area needs to be graded out and if feasible used for re-soiling material.  The pit area needs liming, fertilizing as needed and re-soiling as needed to establish vegetation.  Area C requires:  final grading and seeding.  There are pieces of pit liner around the location, all trash, debris and large rocks must be removed from the area.  Final reclamation work is to be completed by 09/07/2012.  Please contact me when work is started my cell phone number is (330) 283-3204.
 
| I met with the land owner Joe Ann Tabor on location at 08:45 this morning.  I reviewed the location with the land owner and my inspection found the following.  The area affected from oil and gas production and plugging operations needs final grading and seeding completed on it.  The area of the pit is barren and needs Bio-remediation completed on it to establish vegetation. Bio-remediation will include liming and fertilizing as needed to establish vegetation.  I have attached a map to this report designating three areas as A, B and C that still need reclamation work.  Please see the attached map.  Area A requires: final grading and seeding needs to be completed on it.  Area B requires: redistribution of the topsoil,( there is a high area along the south edge of the pad that appears to be topsoil.) This high area needs to be graded out and if feasible used for re-soiling material.  The pit area needs liming, fertilizing as needed and re-soiling as needed to establish vegetation.  Area C requires:  final grading and seeding.  There are pieces of pit liner around the location, all trash, debris and large rocks must be removed from the area.  Final reclamation work is to be completed by 09/07/2012.  Please contact me when work is started my cell phone number is (330) 283-3204.
−
|
 
−
|
 
−
|
 
−
|-
 
 
|-
 
|-
 
| 1379706009
 
| 1379706009
 
| 2013-09-20
 
| 2013-09-20
−
|  
+
| Final Restoration
 +
| No Violations
 
| The dead area cuurently located in the former area of the producing unit has not been addressed.
 
| The dead area cuurently located in the former area of the producing unit has not been addressed.
−
|
 
−
|
 
−
|
 
 
|-
 
|-
 +
| 1701824481
 +
| 2016-08-25
 +
| Final Restoration
 +
| No Violations
 +
| I inspected this well location as an evaluation for Final Restoration. A review of file data indicated that the well was plugged and abandoned in 1992 and a plugging report was submitted. At the time of this inspection, I observed the following: The documented former location of the well was observed to be utilised by the current owner for brush colleciton and as a burn pit location.  I observed no evidence of any remaining production equipment or other signs that there had been a well at the location. Final Restoration is complete.
 
|-
 
|-
 
| 1997519457
 
| 1997519457
 
| 2010-09-01
 
| 2010-09-01
−
|  
+
| UrbanProduction Wells
 +
| No Violations
 
| FOLLOW UP TO NOV #  1283878592 The well was found shut in and disconnected.  Other than sections of flow line, all other equipment had been removed, including the tank battery.  There were two piles of topsoil remaining on location.
 
| FOLLOW UP TO NOV #  1283878592 The well was found shut in and disconnected.  Other than sections of flow line, all other equipment had been removed, including the tank battery.  There were two piles of topsoil remaining on location.
  
 
Post complete identification at the well.
 
Post complete identification at the well.
 
Plug or
 
Plug or
−
|
 
−
|
 
−
|
 
−
|-
 
 
|-
 
|-
 
| 2084532622
 
| 2084532622
 
| 2007-05-08
 
| 2007-05-08
−
|  
+
| Drill / Deepen /  Reopen
 +
| No Violations
 
| rig on site
 
| rig on site
−
|
 
−
|
 
−
|
 
 
|-
 
|-
−
|-
+
| 2116144893
−
| -2116144893
 
 
| 2010-09-01
 
| 2010-09-01
−
|  
+
| UrbanProduction Wells
 +
| No Violations
 
| FOLLOW UP TO NOV #  1283878592 The well was found shut in and disconnected.  Other than sections of flow line, all other equipment had been removed, including the tank battery.  There were two piles of topsoil remaining on location.
 
| FOLLOW UP TO NOV #  1283878592 The well was found shut in and disconnected.  Other than sections of flow line, all other equipment had been removed, including the tank battery.  There were two piles of topsoil remaining on location.
  
 
Post complete identification at the well.
 
Post complete identification at the well.
 
Plug or
 
Plug or
−
|
 
−
|
 
−
|
 
 
|-
 
|-
−
|-
+
| 2127347360
−
| -2127347360
 
 
| 2012-08-23
 
| 2012-08-23
−
|  
+
| Final Restoration
 +
| No Violations
 
| FOLLOW UP TO NOV #  1345747096 I met with the land owner Joe Ann Tabor on location at 08:45 this morning.  I reviewed the location with the land owner and my inspection found the following.  The area affected from oil and gas production and plugging operations needs final grading and seeding completed on it.  The area of the pit is barren and needs Bio-remediation completed on it to establish vegetation. Bio-remediation will include liming and fertilizing as needed to establish vegetation.  I have attached a map to this report designating three areas as A, B and C that still need reclamation work.  Please see the attached map.  Area A requires: final grading and seeding needs to be completed on it.  Area B requires: redistribution of the topsoil,( there is a high area along the south edge of the pad that appears to be topsoil.) This high area needs to be graded out and if feasible used for re-soiling material.  The pit area needs liming, fertilizing as needed and re-soiling as needed to establish vegetation.  Area C requires:  final grading and seeding.  There are pieces of pit liner around the location, all trash, debris and large rocks must be removed from the area.  Final reclamation work is to be completed by 09/07/2012.  Please contact me when work is started my cell phone number is (330) 283-3204.
 
| FOLLOW UP TO NOV #  1345747096 I met with the land owner Joe Ann Tabor on location at 08:45 this morning.  I reviewed the location with the land owner and my inspection found the following.  The area affected from oil and gas production and plugging operations needs final grading and seeding completed on it.  The area of the pit is barren and needs Bio-remediation completed on it to establish vegetation. Bio-remediation will include liming and fertilizing as needed to establish vegetation.  I have attached a map to this report designating three areas as A, B and C that still need reclamation work.  Please see the attached map.  Area A requires: final grading and seeding needs to be completed on it.  Area B requires: redistribution of the topsoil,( there is a high area along the south edge of the pad that appears to be topsoil.) This high area needs to be graded out and if feasible used for re-soiling material.  The pit area needs liming, fertilizing as needed and re-soiling as needed to establish vegetation.  Area C requires:  final grading and seeding.  There are pieces of pit liner around the location, all trash, debris and large rocks must be removed from the area.  Final reclamation work is to be completed by 09/07/2012.  Please contact me when work is started my cell phone number is (330) 283-3204.
−
|
 
−
|
 
−
|
 
−
|-
 
 
|-
 
|-
 
| 348195268
 
| 348195268
−
| 2007-05-16
+
| 2007-5-16 0:00:
−
|  
+
| DD
−
| drilling 260'
+
| No Violations
−
|
 
 
|  
 
|  
 +
|-
 +
| 54405810
 +
| 2012-7-18 0:00:
 +
| AM
 +
| No Violations
 
|  
 
|  
 
|-
 
|-
 +
|}
 +
==== Violations Commited ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Inspection ID
 +
!scope="col" style="text-align: center"| Violation ID
 +
!scope="col" style="text-align: center"| Violation Date
 +
!scope="col" style="text-align: center"| Violation Code
 +
!scope="col" style="text-align: center"| Violation Comments
 
|-
 
|-
−
| -400703373
+
| 1283878592
−
| 2010-09-01
+
| US-OH-107891
−
|
+
| 2010-09-07
−
| FOLLOW UP TO NOV #  1997519457 FOLLOW UP TO NOV #  1283878592 The well was found shut in and disconnected.  Other than sections of flow line, all other equipment had been removed, including the tank battery.  There were two piles of topsoil remaining on location.
 
−
 
 
−
Post complete identification at the well.
 
−
Plug or
 
−
|
 
 
|  
 
|  
 +
| Failure to legibly identify well
 +
|-
 +
| 1283878592
 +
| US-OH-107892
 +
| 2010-09-07
 
|  
 
|  
 +
| Well shall be plugged
 
|-
 
|-
−
|-
+
| 1283878592
−
| 54405810
+
| US-OH-107893
−
| 2012-07-18
+
| 2010-09-07
−
|
 
−
| I was on the phone with Tim Reily from John D, discussing other wells.  I reminded Tim that I was still waiting on a Land Owner Waiver for the lease road on this site.  Tim indicated that the landowner will not sign a waiver.  The landowner was not being reasonable on the amount of final restoration work that they wanted completed.  I informed Tim if the landowner will not sign the waiver, the lease road needs to come out.  Tim advised me that they are short on man power at this time.  I advised Tim to keep working on the waiver.
 
−
|
 
−
|
 
 
|  
 
|  
 +
| Failure to restore land surface within 9 mos.
 
|-
 
|-
−
|-
+
| 1283878592
−
| -626925179
+
| US-OH-107894
−
| 2014-05-16
+
| 2010-09-07
−
|
 
−
| The area formerly occupied by the drilling unit which had been later observed to be devoid of vegetation has been successfully graded and seeded. Other areas of adverse impact from the plugging opertations (e.g. deep ruts in the farm field area) have been re-graded and restored.
 
−
|
 
−
|
 
 
|  
 
|  
 +
| Statement of annual production not filed
 
|-
 
|-
−
|-
+
| 1345747096
−
| -709946149
+
| US-OH-110017
−
| 2007-05-22
+
| 2012-11-05
−
|
 
−
|
 
−
|
 
−
|
 
 
|  
 
|  
 +
| Urban area; failure to complete final restoration within three months
 
|-
 
|-
 
|}
 
|}
 
For data sources see<ref>{{cite web
 
For data sources see<ref>{{cite web
−
  | title = Ohio Department of Natural Resources RBDMS
+
  | title = Risk Based Data Management System - tblInspection, tblInspFail and tblinspFlDesc Tables
−
  | publisher = [http://oilandgas.ohiodnr.gov/]
+
  |publisher = [[Ohio Department of Natural Resources]]
−
  | date = 2015-06-19
+
  | date = 2020-11-16
−
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources#Inspection
+
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
−
  | accessdate = 2015-06-20 }}</ref>
+
  | accessdate = 2020-11-16 }}</ref>
−
== References ==
+
==References==
−
{{reflist}}
+
<references/>
 
__NOEDITSECTION__
 
__NOEDITSECTION__
−
[[Category:Wells]]
+
[[Category:Ohio Wells]]

Latest revision as of 20:36, 11 January 2021

Well Details

Well ID: 34-085-21220
Loading map...
Country: United States
State: Ohio
County: Lake
Municipality: Leroy Township
Operator Name: JOHN D OIL & GAS COMPANY
Well Pad ID:
Farm/Lease Name: PASKAN
License Status: Final Restoration
License Date: 2010-11-01
Spud Date: 2007-05-15
Spud Drilling Contractor: ROSS WELL SERVICE
Final Drill Date: 2007-05-23
Well Total Depth: 3450.00 ft
Configuration: Vertical
Latitude: 41.680000
Longitude: -81.190000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2006-10-16 Proposed Formations:CLINTON, Issued Date:10/16/2006, Expired Date:10/16/2007 6:00:00 AM, Drilling unit acres:20.9, Proposed Well Type:OG, Proposed Well Class:POOL
Completed 2007-05-23
Reached Total Depth 2007-05-23
Completion Report Received 2007-08-09
APP 2008-06-26 Proposed Formations:CLINTON, Issued Date:6/26/2008, Expired Date:6/26/2009 6:00:00 AM, Drilling unit acres:0, Proposed Well Type:OG, Proposed Well Class:
Plugged Back 2008-07-01
APP 2008-07-29 Proposed Formations:OHIO SHALE, Issued Date:7/29/2008, Expired Date:7/29/2009 6:00:00 AM, Drilling unit acres:20.9, Proposed Well Type:OG, Proposed Well Class:ESPW
APP 2010-11-01 Proposed Formations:OHIO SHALE, Issued Date:11/1/2010, Expired Date:10/31/2012 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:OG, Proposed Well Class:
Plugged/Abandoned 2011-09-15
Construction Permit Expires 2011-11-01
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2007-11-05 3229 3284 20
3229 3284 20
3229 3284 20

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 19321 Gal 100000 585M SCF NITROGEN ASSIST

For data sources see[4]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1200452686 2008-7-1 0:00:0 PB No Violations
-1701824481 2016-8-25 0:00: FR No Violations 1.00
-2116144893 2010-9-1 0:00:0 UP No Violations
-2127347360 2012-8-23 0:00: FR No Violations
-400703373 2010-9-1 0:00:0 UP No Violations
-626925179 2014-5-16 0:00: UP No Violations
-709946149 2007-5-22 0:00: DD No Violations
0054405810 2012-07-18 Administrative Inspection No Violations I was on the phone with Tim Reily from John D, discussing other wells. I reminded Tim that I was still waiting on a Land Owner Waiver for the lease road on this site. Tim indicated that the landowner will not sign a waiver. The landowner was not being reasonable on the amount of final restoration work that they wanted completed. I informed Tim if the landowner will not sign the waiver, the lease road needs to come out. Tim advised me that they are short on man power at this time. I advised Tim to keep working on the waiver.
0348195268 2007-05-16 Drill / Deepen / Reopen No Violations drilling 260
0400703373 2010-09-01 UrbanProduction Wells No Violations FOLLOW UP TO NOV # 1997519457 FOLLOW UP TO NOV # 1283878592 The well was found shut in and disconnected. Other than sections of flow line, all other equipment had been removed, including the tank battery. There were two piles of topsoil remaining on location.

Post complete identification at the well. Plug or

0626925179 2014-05-16 UrbanProduction Wells No Violations The area formerly occupied by the drilling unit which had been later observed to be devoid of vegetation has been successfully graded and seeded. Other areas of adverse impact from the plugging opertations (e.g. deep ruts in the farm field area) have been re-graded and restored.
0709946149 2007-05-22 Drill / Deepen / Reopen No Violations
1200452686 2008-07-01 Plug / Plug Back No Violations set lime plug
1283878592 2010-09-01 UrbanProduction Wells Violations Noted The well was found shut in and disconnected. Other than sections of flow line, all other equipment had been removed, including the tank battery. There were two piles of topsoil remaining on location.

Post complete identification at the well. Plug or

1325684310 2011-12-13 Final Restoration No Violations Final grading and seeding has been completed at this site. Vegetation is starting to become established. A land owner waiver will need to be submitted for the lease road, which remains intact.
1345747096 2012-08-23 Final Restoration Violations Noted I met with the land owner Joe Ann Tabor on location at 08:45 this morning. I reviewed the location with the land owner and my inspection found the following. The area affected from oil and gas production and plugging operations needs final grading and seeding completed on it. The area of the pit is barren and needs Bio-remediation completed on it to establish vegetation. Bio-remediation will include liming and fertilizing as needed to establish vegetation. I have attached a map to this report designating three areas as A, B and C that still need reclamation work. Please see the attached map. Area A requires: final grading and seeding needs to be completed on it. Area B requires: redistribution of the topsoil,( there is a high area along the south edge of the pad that appears to be topsoil.) This high area needs to be graded out and if feasible used for re-soiling material. The pit area needs liming, fertilizing as needed and re-soiling as needed to establish vegetation. Area C requires: final grading and seeding. There are pieces of pit liner around the location, all trash, debris and large rocks must be removed from the area. Final reclamation work is to be completed by 09/07/2012. Please contact me when work is started my cell phone number is (330) 283-3204.
1379706009 2013-09-20 Final Restoration No Violations The dead area cuurently located in the former area of the producing unit has not been addressed.
1701824481 2016-08-25 Final Restoration No Violations I inspected this well location as an evaluation for Final Restoration. A review of file data indicated that the well was plugged and abandoned in 1992 and a plugging report was submitted. At the time of this inspection, I observed the following: The documented former location of the well was observed to be utilised by the current owner for brush colleciton and as a burn pit location. I observed no evidence of any remaining production equipment or other signs that there had been a well at the location. Final Restoration is complete.
1997519457 2010-09-01 UrbanProduction Wells No Violations FOLLOW UP TO NOV # 1283878592 The well was found shut in and disconnected. Other than sections of flow line, all other equipment had been removed, including the tank battery. There were two piles of topsoil remaining on location.

Post complete identification at the well. Plug or

2084532622 2007-05-08 Drill / Deepen / Reopen No Violations rig on site
2116144893 2010-09-01 UrbanProduction Wells No Violations FOLLOW UP TO NOV # 1283878592 The well was found shut in and disconnected. Other than sections of flow line, all other equipment had been removed, including the tank battery. There were two piles of topsoil remaining on location.

Post complete identification at the well. Plug or

2127347360 2012-08-23 Final Restoration No Violations FOLLOW UP TO NOV # 1345747096 I met with the land owner Joe Ann Tabor on location at 08:45 this morning. I reviewed the location with the land owner and my inspection found the following. The area affected from oil and gas production and plugging operations needs final grading and seeding completed on it. The area of the pit is barren and needs Bio-remediation completed on it to establish vegetation. Bio-remediation will include liming and fertilizing as needed to establish vegetation. I have attached a map to this report designating three areas as A, B and C that still need reclamation work. Please see the attached map. Area A requires: final grading and seeding needs to be completed on it. Area B requires: redistribution of the topsoil,( there is a high area along the south edge of the pad that appears to be topsoil.) This high area needs to be graded out and if feasible used for re-soiling material. The pit area needs liming, fertilizing as needed and re-soiling as needed to establish vegetation. Area C requires: final grading and seeding. There are pieces of pit liner around the location, all trash, debris and large rocks must be removed from the area. Final reclamation work is to be completed by 09/07/2012. Please contact me when work is started my cell phone number is (330) 283-3204.
348195268 2007-5-16 0:00: DD No Violations
54405810 2012-7-18 0:00: AM No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1283878592 US-OH-107891 2010-09-07 Failure to legibly identify well
1283878592 US-OH-107892 2010-09-07 Well shall be plugged
1283878592 US-OH-107893 2010-09-07 Failure to restore land surface within 9 mos.
1283878592 US-OH-107894 2010-09-07 Statement of annual production not filed
1345747096 US-OH-110017 2012-11-05 Urban area; failure to complete final restoration within three months

For data sources see[5]