{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.608525,"lon":-75.973233,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Wyoming | |
Municipality: Washington Township | |
Operator Name: BKV OPR LLC | |
Well Pad ID: 145313 | |
Farm/Lease Name: SICKLER 6H | |
License Status: | |
Spud Date: 2011-04-12 | |
Permit Date: 2011-03-22 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.608525 | |
Longitude: -75.973233 |
Date | Event |
---|---|
2011-03-22 | New Permit Application |
2011-03-28 | Performed Spud Operation |
2011-10-23 | Drilling Completion |
2012-03-05 | DEVIATED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2012-06-24 | 2012-06-24 | 7,928 | 7,836,738 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | CI-14 | Baker Hughes | Corrosion Inhibitor | Alkenes, C>10 .alpha.- | 64743-02-8 | 5.00 | 0.00006000 | |
Ethoxylated C14-15 alcohols | 68951-67-7 | 30.00 | 0.00035000 | |||||
Methanol | 67-56-1 | 100.00 | 0.00116000 | |||||
Fatty acids, tall-oil | 61790-12-3 | 10.00 | 0.00012000 | |||||
Propargyl alcohol | 107-19-7 | 5.00 | 0.00006000 | |||||
Water | Operator | Carrier | Water | 7732-18-5 | 100.00 | 88.11 | ||
Sand, White, 100 mesh | Baker Hughes | Proppant | Quartz | 14808-60-7 | 100.00 | 0.75 | ||
FRW-18 | Baker Hughes | Friction Reducer | Distillates, petroleum, hydrotreated light | 64742-47-8 | 30.00 | 0.02 | ||
Ingredients shown above are subject to 29 CFR 1910.1200(i) and appear on Material Safety Data Sheets (MSDS). Ingredients shown below are Non-MSDS. |
Baker Hughes | Surfactant | Poly (acrylamide-co-acrylic acid) | 0.02 | ||||
Water | 7732-18-5 | 0.06 | ||||||
Sorbitan Monooleate | 0.00441629 | |||||||
Hydrochloric acid | 7647-01-0 | |||||||
Formalin | 50-00-0 | |||||||
Sodium chloride | 7647-14-5 | 0.00000454 | ||||||
Thiourea polymer | 68527-49-1 | |||||||
Salt | 0.00441629 | |||||||
Polyacrylate | 0.00302666 | |||||||
Potassium chloride | 7447-40-7 | 0.00000757 | ||||||
Ethoxylated Alcohol | 0.00176651 | |||||||
Alpha 1427 | Baker Hughes | Biocide | Didecyl dimethyl ammonium chloride | 7173-51-5 | 10.00 | 0.00220000 | ||
Quaternary ammonium compounds, benzyl-C12-16-alkyldimethyl, chlorides |
68424-85-1 | 5.00 | 0.00110000 | |||||
Ethanol | 64-17-5 | 5.00 | 0.00110000 | |||||
Glutaraldehyde | 111-30-8 | 30.00 | 0.00659000 | |||||
Ingredients shown above are subject to 29 CFR 1910.1200(i) and appear on Material Safety Data Sheets (MSDS). Ingredients shown below are Non-MSDS. |
||||||||
Sand, White, 40/70 | Baker Hughes | Proppant | Quartz | 14808-60-7 | 100.00 | 4.25 | ||
Ferrotrol 300L | Baker Hughes | Iron Control | Citric acid | 77-92-9 | 60.00 | 0.00303000 | ||
Scaletrol 720 | Baker Hughes | Scale Inhibitor | Ethylene glycol | 107-21-1 | 30.00 | 0.00454000 | ||
Calcium chloride | 10043-52-4 | 5.00 | 0.00076000 | |||||
Hydrochloric Acid 5.1-7.5 | Baker Hughes | Acidizing | Hydrochloric acid | 7647-01-0 | 7.50 | 0.06 | ||
Water | 7732-18-5 | 92.50 | 0.75 | |||||
Sand, White, 30/50 | Baker Hughes | Proppant | Quartz | 14808-60-7 | 100.00 | 5.52 | ||
Hydrochloric Acid 10.1-15 | Baker Hughes | Acidizing | Water | 7732-18-5 | 85.00 | 0.31 | ||
Hydrochloric acid | 7647-01-0 | 15.00 | 0.05 | |||||
InFlo 250W | Baker Hughes | Surfactant | Surfactants | 80.00 | 0.00107000 | |||
Methanol | 67-56-1 | 30.00 | 0.00040000 | |||||
2-Butoxyethanol | 111-76-2 | 5.00 | 0.00007000 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2011 | CARRIZO (MARCELLUS) LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | CARRIZO (MARCELLUS) LLC | 423,971.00 | 61 | 0.00 | 0 | 0.00 | 0 |
2013 | CARRIZO (MARCELLUS) LLC | 2,895,108.00 | 309 | 0.00 | 0 | 0.00 | 0 |
2014 | CARRIZO (MARCELLUS) LLC | 1,011,886.54 | 173 | 0.00 | 0 | 0.00 | 0 |
2015 | CARRIZO (MARCELLUS) LLC | 602,596.17 | 143 | 0.00 | 0 | 0.00 | 0 |
2016 | CARRIZO (MARCELLUS) LLC | 1,439,783.68 | 309 | 0.00 | 0 | 0.00 | 0 |
2017 | CARRIZO (MARCELLUS) LLC | 1,932,856.86 | 365 | 0.00 | 0 | 0.00 | 0 |
2018 | BKV OPR LLC | 1,287,272.94 | 364 | 0.00 | 0 | 0.00 | 0 |
2019 | BKV OPR LLC | 1,179,302.27 | 362 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2011 | CARRIZO (MARCELLUS) LLC | Drilling Fluid Waste | 3,872.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0008451 |
2011 | CARRIZO (MARCELLUS) LLC | Drilling Fluid Waste | 1,190.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0102784 |
2011 | CARRIZO (MARCELLUS) LLC | Drill Cuttings | 850.00 Tons | LANDFILL | NY STATE #32S11 |
2012 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 666.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 860.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 154.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE003 |
2014 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 200.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW018 |
2014 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 605.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 320.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR119 |
2014 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 132.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE003 |
2015 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 86.96 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
2015 | CARRIZO (MARCELLUS) LLC | Basic Sediment | 62.70 Bbl | LANDFILL | THR029 |
2015 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 187.12 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE003 |
2015 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 106.65 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
2015 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 630.90 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 71.35 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2016 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 232.33 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE003 |
2016 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 65.78 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE003 |
2016 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 113.19 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2016 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 337.50 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
2016 | CARRIZO (MARCELLUS) LLC | Basic Sediment | 12.14 Bbl | LANDFILL | THR029 |
2016 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 23.41 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
2017 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 52.23 Bbl | REUSE (AT WELL PAD) | |
2017 | CARRIZO (MARCELLUS) LLC | Other Oil & Gas Wastes | 1.03 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE003 |
2017 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 29.59 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2017 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 244.97 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2017 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 268.59 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE003 |
2018 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 334.69 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2018 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 89.85 Bbl | REUSE (AT WELL PAD) | |
2019 | BKV OPR LLC | Synthetic Liner Materials | 0.29 Tons | ||
2019 | BKV OPR LLC | Produced Fluid | 10.83 Bbl | REUSE (AT WELL PAD) | |
2019 | BKV OPR LLC | Synthetic Liner Materials | 1.26 Tons | RESIDUAL WASTE TRANSFER FACILITY | 101714 |
2019 | BKV OPR LLC | Synthetic Liner Materials | 0.29 Tons | BENEFICIAL REUSE ?PERMIT | |
2019 | BKV OPR LLC | Produced Fluid | 401.82 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1962536 | Primary Facility | 2011-04-01 | Drilling/Alteration | No Violations Noted | hole wet from 40' - 60' |
1965665 | Primary Facility | 2011-04-14 | Drilling/Alteration | No Violations Noted | drillers log up to date |
1966411 | Primary Facility | 2011-04-18 | Drilling/Alteration | No Violations Noted | Rig - Falcon 14(Ingersol Rand) checked cellar - no bubbles Drillers log - checked |
1968962 | Primary Facility | 2011-04-28 | Routine/Complete Inspection | No Violations Noted | this well is done to intermediate csg, moved rig to the Sickler 1H |
1984832 | Primary Facility | 2011-06-28 | Follow-up Inspection | No Violations Noted | Inspection is in response to reported spill. Rig is in process of moving from Solanick to Sickler site.Company Man, Jeff Myers, has MSDS sheets on OB mud in trailer. Night shift topped off mud tank, then in the heat of the day, expansion caused the tank to overflow.Spill was found on 6/27/2011 around 1300. Super vac was here in about 1/2 hour. Total of about 30 gallons over the top with about 5 - 10 gallons splashing off containment. Dirt &fill was dug out and put in waste. Area was about 10' X 10' X 1' deep. Completely cleaned up at this time. Took 3 pictures. Company man had tank level lowerewd immediately so it wouldn't happen again. |
1991507 | Primary Facility | 2011-07-28 | Drilling/Alteration | No Violations Noted | H&P 320 , Comp Man Jeff Myers |
2009958 | Primary Facility | 2011-10-11 | Drilling/Alteration | No Violations Noted | H&P 320, Comp. Man - John Savage |
2013430 | Primary Facility | 2011-10-17 | Drilling/Alteration | No Violations Noted | H&P 320 Comp. Man - Tim Peay checked drillers log, drilling at 14600' |
2029524 | Primary Facility | 2011-12-27 | Routine/Complete Inspection | No Violations Noted | |
2064936 | Primary Facility | 2012-04-23 | Follow-up Inspection | Pending | Responding to a complaint. Had water-vac truck fill and empty cellar. Bubbles were coming up but due to well configuation unable to tell which annulus they were coming from. It was either the 20 X 13 3/8" or the 13 3/8 X 9 5/8". Bubbles were coming up in 3 spots. Also on site was Gary Byron, Jesse Bonnice, and Steve Osburne.Workover rig was on site on the 2H to clean out and perf in prep for frac. Need to get containment in shape. |
2341050 | Primary Facility | 2015-02-04 | Routine/Partial Inspection | No Violations Noted | |
2382664 | Primary Facility | 2015-06-26 | Routine/Partial Inspection | No Violations Noted | |
2426467 | Primary Facility | 2015-11-09 | Routine/Complete Inspection | No Violations Noted | |
2489933 | Primary Facility | 2016-05-31 | Administrative/File Review | No Violations Noted | This administration inspection is created to document a spill of production fluid that occurred at the site on 5/11/16. The Department received an e-mail in reference to the spill incident from the PADEP Northeast Regional Office Emergency Response Team on 5/17/16 at 10:33 AM. Matt Shope and Frank Hoehle, DEP O&G WQS, and I responded to the spill incident on 5-17-16 at 13:30. There was no activity or personnel at the site during the inspection. It had been apparent the spill had been remediated. Stone was placed over the original pad material on the pad surface impacted by the production fluid spill. Conductivity of water in the production fluid tanks containment structure near the containment wall and one of the tanks was (9) milliSiemens/cm³. I did not record any elevated soil conductivity readings of concern in the general area of the pad surface where the spill occurred. There is staining/discoloration of water and /or fluid on the side walls of the production fluid tanks and the containment l |
2537145 | Primary Facility | 2016-11-15 | Routine/Partial Inspection | No Violations Noted | |
2599600 | Primary Facility | 2017-05-19 | Routine/Partial Inspection | No Violations Noted | There was no activity occurring at the site. No further comments. |
2641322 | Primary Facility | 2017-09-14 | Routine/Partial Inspection | No Violations Noted | There was no activity occurring at the site during the inspection. There were no violations noted. If you have any questions, please contact me. |
2661530 | Primary Facility | 2017-11-06 | Routine/Complete Inspection | No Violations Noted | Arrived on location to perform routine inspection and update status of wells. 6 wells on location. 6 treaters, 6 separators and 4 tanks. All cellars filled with water with no apparent bubbling. Prod casing pressures are as follows: 1H = 500psi, 2H = 500psi, 3 = 600psi, 4 = 400psi, 5 = 600psi, 6 = 500psi. No issues or concerns at time of inspection. |
For data sources see[8]