{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.739369,"lon":-75.766169,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Susquehanna | |
Municipality: Brooklyn Township | |
Operator Name: CABOT OIL & GAS CORP | |
Well Pad ID: 153695 | |
Farm/Lease Name: FOLTZ J 14 | |
License Status: | |
Spud Date: | |
Permit Date: 2016-04-29 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.739369 | |
Longitude: -75.766169 |
Date | Event |
---|---|
Deviated | |
2016-04-29 | New Permit Application |
2017-04-02 | Performed Spud Operation |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2017-11-14 | 2017-12-07 | 7,120 | 13,594,700 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Hydrochloric Acid (15%) | Keane | Acidizing | Water | 7732-18-5 | 7.5 | 0.0183817 | 23888 |
Hydrochloric Acid | 7647-01-0 | 15 | 0.0367634 | 47776 | ||||
Sand (Proppant) | Keane | Proppant | Crystalline silica: Quartz (SiO2) | 14808-60-7 | 100 | 12.3266 | 16,019,000.0 | |
Iron Control, KFEAC-20/30 | Keane | Iron Control | Citric acid | 77-92-9 | 30 | 0.000639576 | 831.162 | |
Acetic acid | 64-19-7 | 5 | 0.000106596 | 138.527 | ||||
Scale Inhibitor, KSI-19NW | Keane | Scale Inhibitor | Water | 7732-18-5 | 95 | 0.017333 | 22525.1 | |
organic phosphonic salts | 15827-60-8 | 15 | 0.00273679 | 3556.6 | ||||
Other Chemical(s) | Listed Above | See Trade Name(s) List | alcohols, C 12-16, ethoxylated | 68551-12-2 | 5 | 0.0050325 | 6539.99 | |
Cinnamaldehyde | 104-55-2 | 10 | 0.00007577 | 98.471 | ||||
formic acid | 64-18-6 | 10 | 0.00007577 | 98.471 | ||||
Ethoxylated alcohol | 68131-39-5 | 10 | 0.00007577 | 98.471 | ||||
Copolymer of 2-propenamide | 69418-26-4 | 5 | 0.0050325 | 6539.99 | ||||
Glutaral | 111-30-8 | 26.7 | 0.00241774 | 3141.98 | ||||
quaternary ammonium compounds, benzyl-C12-16-alkyldimethyl, chlorides |
68424-85-1 | 5.3 | 0.000480831 | 624.865 | ||||
didecyldimethylammonium chloride | 7173-51-5 | 8 | 0.000721699 | 937.886 | ||||
isoproyl alcohol | 67-63-0 | 5 | 0.00003789 | 49.236 | ||||
Water | 7732-18-5 | 7.5 | 0.0183817 | 23888 | ||||
Tar bases, quinoline derivs., benzyl chloride-quaternized | 72480-70-7 | 10 | 0.00007577 | 98.471 | ||||
Citric acid | 77-92-9 | 30 | 0.000639576 | 831.162 | ||||
Petroleum distillate | 64742-47-8 | 1 | 0.0010065 | 1308 | ||||
ammonium chloride | 12125-02-9 | 30 | 0.030195 | 39240 | ||||
organic phosphonic salts | 15827-60-8 | 15 | 0.00273679 | 3556.6 | ||||
dipropylene gylcol, monomethyl ether | 34590-94-8 | 20 | 0.000151546 | 196.942 | ||||
ethonal | 64-17-5 | 2.8 | 0.000253546 | 329.496 | ||||
oleic acid diethanolamide | 93-83-4 | 1 | 0.0010065 | 1308 | ||||
Biocide, MBC-516 | Keane | Biocide | ethonal | 64-17-5 | 2.8 | 0.000253546 | 329.496 | |
quaternary ammonium compounds, benzyl-C12-16-alkyldimethyl, chlorides |
68424-85-1 | 5.3 | 0.000480831 | 624.865 | ||||
Water | 7732-18-5 | 56.7 | 0.00513611 | 6674.64 | ||||
didecyldimethylammonium chloride | 7173-51-5 | 8 | 0.000721699 | 937.886 | ||||
Glutaral | 111-30-8 | 26.7 | 0.00241774 | 3141.98 | ||||
Acid Inhibitor, KAI-12 | Keane | Acid Inhibitor | Tar bases, quinoline derivs., benzyl chloride-quaternized | 72480-70-7 | 10 | 0.00007577 | 98.471 | |
dipropylene gylcol, monomethyl ether | 34590-94-8 | 20 | 0.000151546 | 196.942 | ||||
formic acid | 64-18-6 | 10 | 0.00007577 | 98.471 | ||||
Ethoxylated alcohol | 68131-39-5 | 10 | 0.00007577 | 98.471 | ||||
isoproyl alcohol | 67-63-0 | 5 | 0.00003789 | 49.236 | ||||
Cinnamaldehyde | 104-55-2 | 10 | 0.00007577 | 98.471 | ||||
Ethylene glycol | 107-21-1 | 40 | 0.000303092 | 393.884 | ||||
Water | Cabot | Carrier/Base Fluid | Water | 7732-18-5 | 100 | 87.2975 | 113,448,000.0 | |
Friction Reducer, KFR-20 | Keane | Friction Reducer | Copolymer of 2-propenamide | 69418-26-4 | 5 | 0.0050325 | 6539.99 | |
Water | 7732-18-5 | 30 | 0.030195 | 39240 | ||||
Petroleum distillate | 64742-47-8 | 1 | 0.0010065 | 1308 | ||||
alcohols, C 12-16, ethoxylated | 68551-12-2 | 5 | 0.0050325 | 6539.99 | ||||
ammonium chloride | 12125-02-9 | 30 | 0.030195 | 39240 | ||||
oleic acid diethanolamide | 93-83-4 | 1 | 0.0010065 | 1308 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2017 | CABOT OIL & GAS CORP | 107,699.46 | 9 | 0.00 | 0 | 0.00 | 0 |
2018 | CABOT OIL & GAS CORP | 4,666,194.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2019 | CABOT OIL & GAS CORP | 2,314,113.00 | 364 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2017 | CABOT OIL & GAS CORP | Synthetic Liner Materials | 14.09 Tons | LANDFILL | 101247 |
2017 | CABOT OIL & GAS CORP | Waste Water Treatment Sludge | 42.75 Tons | REUSE (AT WELL PAD) | |
2017 | CABOT OIL & GAS CORP | Servicing Fluid | 17.50 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2017 | CABOT OIL & GAS CORP | Produced Fluid | 221.21 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2017 | CABOT OIL & GAS CORP | Produced Fluid | 4,070.28 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE004 |
2017 | CABOT OIL & GAS CORP | Unused Fracturing Fluid Waste | 9.77 Tons | LANDFILL | 101247 |
2017 | CABOT OIL & GAS CORP | Produced Fluid | 10,732.26 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2017 | CABOT OIL & GAS CORP | Waste Water Treatment Sludge | 210.31 Tons | LANDFILL | 100933 |
2017 | CABOT OIL & GAS CORP | Drill Cuttings | 1,420.09 Tons | LANDFILL | 101247 |
2018 | CABOT OIL & GAS CORP | Soil Contaminated by Oil & Gas Related Spills | 7.70 Tons | LANDFILL | 101247 |
2018 | CABOT OIL & GAS CORP | Synthetic Liner Materials | 20.19 Tons | LANDFILL | 101247 |
2018 | CABOT OIL & GAS CORP | Produced Fluid | 5,847.93 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2018 | CABOT OIL & GAS CORP | Waste Water Treatment Sludge | 29.94 Tons | REUSE (AT WELL PAD) | |
2018 | CABOT OIL & GAS CORP | Soil Contaminated by Oil & Gas Related Spills | 0.13 Tons | RESIDUAL WASTE PROCESSING FACILITY | 301333 |
2018 | CABOT OIL & GAS CORP | Unused Fracturing Fluid Waste | 3.67 Tons | LANDFILL | 101247 |
2018 | CABOT OIL & GAS CORP | Soil Contaminated by Oil | 0.13 Tons | RESIDUAL WASTE PROCESSING FACILITY | 301333 |
2018 | CABOT OIL & GAS CORP | Soil Contaminated by Oil | 7.70 Tons | LANDFILL | 101247 |
2018 | CABOT OIL & GAS CORP | Produced Fluid | 11,708.55 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE004 |
2018 | CABOT OIL & GAS CORP | Produced Fluid | 2,854.39 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2018 | CABOT OIL & GAS CORP | Other Oil & Gas Wastes | 0.02 Tons | RESIDUAL WASTE PROCESSING FACILITY | 301333 |
2019 | CABOT OIL & GAS CORP | Produced Fluid | 730.88 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2019 | CABOT OIL & GAS CORP | Synthetic Liner Materials | 1.92 Tons | LANDFILL | 100933 |
2019 | CABOT OIL & GAS CORP | Produced Fluid | 567.76 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE004 |
2019 | CABOT OIL & GAS CORP | Synthetic Liner Materials | 0.41 Tons | LANDFILL | 101247 |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2584991 | Primary Facility | 2017-04-20 | Preoperation Inspection | No Violations Noted | Well site pre-operational inspection conducted on 3/28/17. Site is approximately 98% complete. Seed and mulching about 90% complete. The site has been built per plan. No violations noted. The Arnone Pad located across the street will be utilized as the tank pad. |
2600259 | Primary Facility | 2017-05-31 | Drilling/Alteration | No Violations Noted | 20" Conductor and 16" Mouseholes have been installed. Cellar Tech well cellars have been installed and Liner and drilling mats installed in preparation for drilling of (6) newe wells on theis pad. The Foltz 9H, 10H, 11H, 12H, 13H, & 14 H wells. No violations were noted. |
2601784 | Primary Facility | 2017-06-07 | Drilling/Alteration | No Violations Noted | |
2621304 | Primary Facility | 2017-07-28 | Drilling/Alteration | No Violations Noted | |
2631198 | Primary Facility | 2017-08-30 | Routine/Partial Inspection | No Violations Noted | At time of inspection.
Conducted a routine inspection for a possible migration investigation. I was accompanied by Trudy Graby (Oil and Gas Inspector Supervisor). We met with Steve Brominski, Ken Wilson, and Steve Watson of Cabot Oil and Gas. The annuli were disconnected in the cellar so we were unable to check for gas shows, but we noticed latex gloves on the annuli and the gloves on the (13x9) annulus of the 10H, 11H, 12H, and 14H appeared to be inflated. Steve Brominski said Cabot would have the annuli plumbed to the surface for inspection access. The department will return at 1:00 p.m. on 8/31/17 to check for gas show and take samples if gas is detected. |
2634165 | Primary Facility | 2017-08-31 | Complaint Inspection | Violation(s) Noted | Upon arrival to site, Cabot has had all (6) wells annuli, the (20¿ x 13 3/8¿), (13 3/8¿ x 9 5/8¿) and (9 5/8¿ x 5 ½¿) separated and plumbed to surface. All annular vents have been open and venting separately for approx. 4 hrs prior to screening.
All (6) wells, the Foltz, J. 9H, 10H, 11H, 12H, 13H and 14H were recently drilled to TD and have been toe prepped in preparation for well stimulation operations. All wells were shut in at time of inspection. Personnel Present: Cabot O&G Reps: Steve Watson, Jerry Dugas and Mike Bail. Selma Associates: Matt and Bret. DEP Reps: Eric Rooney and Myself. DEP gas screenings were performed using a ALTAIR 5X gas meter calibrated on 8/30/2017. All samples taken by DEP were also taken by Selman Associates on Cabots behalf. See Violations Comments section DEP annular gas readings detected and further explaination of violation cited. Please contact me with any questions you may have. Kenkennedy@ pa.gov. |
2643380 | Primary Facility | 2017-09-06 | Routine/Complete Inspection | No Violations Noted | Followup visit from previous week to determine if any additional equipment was mobilized onto site for frac ops. At time of inspection, no additional equipment was mobilized to location for frac ops. Wireline was on location, however was sitting idle and no activity was taking place at time of inspection. |
2657055 | Primary Facility | 2017-10-19 | Routine/Complete Inspection | No Violations Noted | I arrived at the site at 11:35. The weather conditions were sunny skies with temperatures in the low to mid 60's, with light winds. I met with Travis Routan, driller of Stone Well Service. Mr. Routan provided the following information in reference to site activities. "We have been squeezing cement in the 13H and 10H wells. Just completed the 13H. The cement is coming up the back side of the production casing. The intent of squeezing the cement is to keep the gas in the production casing. The rig has been laid down today and will be going to the Cabot Howell Pad to perform a similar task. The Erick Flowback Services gas buster tank on containment is there to contain a kick of gas if it occurs. The blue tank is cement and water that comes out of the well. Sawdust is in the red tank. It is used for the wet cement solidification and mixed in the blue tank. Green frac tanks will be used during the frac." I left the site at 12:43. |
2670908 | Primary Facility | 2017-12-04 | Incident- Response to Accident or Event | No Violations Noted | I arrived at the site at 12:02 in response to a reported spill of (12) gallons of diesel fuel that occurred on 12/2/17. The weather conditions are partly cloudy skies with temperatures around 40 degrees. I met with Wayne Wilridge, Safety and Regulatory Compliance and Ken Wilson, EHS Completions Foreman, both consultants of Cabot Oil and Gas. Mr. Wilson and Mr. Wilridge informed me of the following details associated with the spill. "We were first notified of the spill at 1:40 PM on 12/2/17. The spill occurred as a result of a fuel cap not secured on the tank in the back of a pickup truck. The truck picked up fuel in a (1,000) gallon in capacity above ground fuel cell on the Foltz pad where Keane is conducting the frac. The truck was headed to the Arnone to fuel generators and heaters on the tank pad section of the site. Diesel fuel overflowed the tank onto the truck bed and flowed out of the corner of the tailgate to the Foltz pad access road near the pad entrance, on the entire length of the Foltz pad acces |
2677341 | Primary Facility | 2017-12-27 | Incident- Response to Accident or Event | Viol(s) Noted & Immediately Corrected | At 2:30 pm on December 26, 2017 during flowback operations on the Foltz J Well Site, Baker had a saddle blow out on the water manifold due to a valve not closing all the way on the tank battery. The tank battery is not currently operational and is in the process of being disassembled. The company is now working out of water trucks. About 2 to 2.5 bbls of flowback water hit the ground.
The release was immediately vacuumed up with a vac truck on site. Approximately 12 yards of impacted material was dug up and was still on site in a lined rolloff container awaiting disposal. Resource Environmental performed screening on December 26 and 27, 2017 during excavating. Screening was measured below 300 uS during excavation. According to Ken Wilson, Env'l Health and Safety contractor, the rolloff container will remain on site pending a decision on where it is to be sent. Resource representatives had recently left and were not on site at the time of inspection. I spoke with Chad Miller, Cabot contracted flowback |
2677556 | Primary Facility | 2017-12-20 | Routine/Complete Inspection | No Violations Noted | Arrived onsite at 13:45. The stimulation operations of all (6) wells on pad has been completed. (2) rigs were onsite in process of performing plug DO operations. Rigs were presently rigged up completing DO on the 10H and 13H wells. Upon arrival I met with Cabot WSS, Steve Brominski and Cabots HSE Rep. onsite.
Mr. Brominski informed that DO operations have been completed on the 9H, 11H, 12H and 14H wells. Rig was presently finishing up on the 13H and Rig on the 10H was approx. half way through DO. He anticipates being completed with DO operations sometime tomorrow. I asked whether any issues had been encountered during stimulation or DO ops. Specifically in the 10H and 13H wells due to the prod. casing patches installed in these wells during remedial work performed prior to stimulations. No issues had been encountered to this point. I collected the number of stages stimulated for each well from the HSE Rep. See individual well inspections for these numbers. Overall, wells and location were found in good con |
2705550 | Primary Facility | 2018-03-14 | Routine/Complete Inspection | No Violations Noted | Today's inspection was conducted as a routine inspection. No E&S issues were identified. No violations noted. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
2634165 | 796051 | 2017-09-06 | 78a86 | Environmental Health & Safety | ||
2677341 | 805428 | 2017-12-27 | 2017-12-27 | CSL 402(b) | Environmental Health & Safety | The release of flowback fluid to the wellpad surface causes the potential for pollutional substances to enter the waters of the Commonwealth. |
2677341 | 805429 | 2017-12-27 | 2017-12-27 | SWMA 301 | Environmental Health & Safety | The release was discharged onto the well pad surface. |
2677341 | 805430 | 2017-12-27 | 2017-12-27 | 78a56(a) | Environmental Health & Safety | The flowback fluid was not properly contained. |
For data sources see[8]