If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-115-21651 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.675692,"lon":-75.972931,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Susquehanna | |
Municipality: Auburn Township | |
Operator Name: CABOT OIL & GAS CORP | |
Well Pad ID: 150844 | |
Farm/Lease Name: HAWK J 2 | |
License Status: | |
Spud Date: | |
Permit Date: 2014-02-25 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.675692 | |
Longitude: -75.972931 |
Date | Event |
---|---|
2014-02-25 | New Permit Application |
2014-04-16 | Performed Spud Operation |
2014-07-08 | Drilling Completion |
2014-09-27 | Perforation |
2014-11-18 | Performed Stimulation |
2015-03-13 | DEVIATED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2014-11-17 | 2014-12-29 | 7,152 | 7,898,560 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | FE-4 | PVS Chemical | Iron Controller / Reducers | Water | 7732-18-5 | 50 | 0.000557363 | 414.735 |
Citric Acid | 77-92-9 | 50 | 0.000557363 | 414.735 | ||||
MSI-7 | PVS Energy Group | Scale Inhibitor | Water | 7732-18-5 | 91.3 | 0.0205592 | 15298.2 | |
Hydrocloric Acid | 7647-01-0 | 9 | 0.00202776 | 1508.86 | ||||
FR900 | Nalco | Friction Reducer | Anionic Polymer | 136793-29-8 | 5 | 0.00553994 | 4122.27 | |
Vinyl Copolymer | 38193-60-1 | 20 | 0.0221597 | 16489.1 | ||||
Urea | 57-13-6 | 5 | 0.00553994 | 4122.27 | ||||
Ammonium Sulfate | 7783-20-2 | 25 | 0.0276997 | 20611.4 | ||||
Water | 7732-18-5 | 65 | 0.0720192 | 53589.6 | ||||
I-22 | Nalco | Acid Inhibitor | Aromatic Aldehyde | 104-55-2 | 30 | 0.00030805 | 229.22 | |
Organic Sulfur Compound | 60-24-2 | 5 | 0.00005134 | 38.203 | ||||
Water | 7732-18-05 | 3 | 0.00003081 | 22.922 | ||||
Quaternary Ammonium Compound | 68909-18-2 | 5 | 0.00005134 | 38.203 | ||||
Formic Acid | 64-18-6 | 50 | 0.000513417 | 382.034 | ||||
Terpene | 800-09-03 | 10 | 0.000102683 | 76.407 | ||||
Alkylene oxide block polymer | 9003-11-006 | 5 | 0.00005134 | 38.203 | ||||
Quaternary Ammonium Compound | 192562-10-6 | 30 | 0.00030805 | 229.22 | ||||
Methanol | 67-56-1 | 3 | 0.00003081 | 22.922 | ||||
Oxyalkylated Fatty Acid | 61791-12-6 | 30 | 0.00030805 | 229.22 | ||||
Substituted Alcohol | 67-63-0 | 10 | 0.000102683 | 76.407 | ||||
Sand (Proppant) | Silica | Proppant | Crystalline Silica in the form of Quartz | 14808-60-7 | 99.9 | 10.7383 | 7,990,350.0 | |
AI 30 | CorsiTech | Corrosion Inhibitor | Isopropyl Alcohol | 67-63-0 | 60 | 0.000266986 | 198.665 | |
Fatty Alcohol Ethoxylate | Proprietary | 30 | 0.000133493 | 99.332 | ||||
Ethoxylated Alcohol | Proprietary | 10 | 0.00004450 | 33.111 | ||||
Alkyl Amine Surfactant | Proprietary | 5 | 0.00002225 | 16.555 | ||||
Aromatic Aldehyne | Proprietary | 10 | 0.00004450 | 33.111 | ||||
Hydrochloric Acid (15%) | Reagent | Acidizing | Hydrogen Chloride | 7647-01-0 | 15 | 0.0759456 | 56511.3 | |
Water | Cabot | Carrier/Base Fluid | Water | 7732-18-5 | 100 | 88.5813 | 65,913,500.0 | |
B2000 | Weatherford | Biocide | 2,2-Dibromo-3-Nitrilopropionamide | 10222-01-2 | 20 | 0.0054847 | 4081.17 | |
Polyethylene Glycol Mixture | 25322-68-3 | 60 | 0.0164541 | 12243.5 |
For data sources see[5]
Stimulation Date | Phase Number | Chemical Agent | Volume (gal) | Treating Pressure (psi) | Breakdown Pressure (psi) |
---|---|---|---|---|---|
2014-11-18 | 0 | 0 | 0 |
For data sources see[6]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2014 | CABOT OIL & GAS CORP | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2015 | CABOT OIL & GAS CORP | 2,730,309.67 | 342 | 0.00 | 0 | 0.00 | 0 |
2016 | CABOT OIL & GAS CORP | 3,240,172.38 | 366 | 0.00 | 0 | 0.00 | 0 |
2017 | CABOT OIL & GAS CORP | 1,635,238.19 | 363 | 0.00 | 0 | 0.00 | 0 |
2018 | CABOT OIL & GAS CORP | 1,276,613.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2019 | CABOT OIL & GAS CORP | 961,739.00 | 365 | 0.00 | 0 | 0.00 | 0 |
For data sources see[7]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2014 | CABOT OIL & GAS CORP | Fracing Fluid Waste | 15.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE001 |
2014 | CABOT OIL & GAS CORP | Drill Cuttings | 1,510.05 Tons | LANDFILL | 101247 |
2014 | CABOT OIL & GAS CORP | Fracing Fluid Waste | 296.50 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2015 | CABOT OIL & GAS CORP | Fracing Fluid Waste | 220.05 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE001 |
2015 | CABOT OIL & GAS CORP | Fracing Fluid Waste | 12,151.22 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2015 | CABOT OIL & GAS CORP | Produced Fluid | 3,144.30 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2015 | CABOT OIL & GAS CORP | Produced Fluid | 4.26 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE001 |
2016 | CABOT OIL & GAS CORP | Produced Fluid | 305.28 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2016 | CABOT OIL & GAS CORP | Produced Fluid | 569.34 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2017 | CABOT OIL & GAS CORP | Produced Fluid | 181.56 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2017 | CABOT OIL & GAS CORP | Produced Fluid | 296.53 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2018 | CABOT OIL & GAS CORP | Produced Fluid | 184.65 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2018 | CABOT OIL & GAS CORP | Produced Fluid | 73.99 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2019 | CABOT OIL & GAS CORP | Produced Fluid | 254.28 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2019 | CABOT OIL & GAS CORP | Synthetic Liner Materials | 0.04 Tons | RESIDUAL WASTE TRANSFER FACILITY | 101714 |
For data sources see[8]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2254379 | Primary Facility | 2014-03-18 | Preoperation Inspection | No Violations Noted | |
2266714 | Primary Facility | 2014-04-29 | Drilling/Alteration | No Violations Noted | Conductor set |
2325869 | Primary Facility | 2014-11-20 | Routine/Complete Inspection | No Violations Noted | Hydraulic fracturing operations were in progress at the location. An employee of Rain for Rent stated to me that casing perforation operations were in progress. I recorded (8.4) millisiemens/cm conductivity in fluid pooled in the recycled water tank battery secondary containment system. The frac tanks in this tank battery which is set up next to the AST, are enclosed with plastic sheeting in an attempt to prevent the fluid in the tanks from freezing. The recycled water is a mixture of mainly flowback and production fluid treated at Cabot’s A&M Hibbard Treatment Facility. I encountered Larry Fulmer, frac superintendent and consultant of Cabot Oil and Gas on the lease while departing from the site. Mr. Fulmer informed me that well stimulation procedures were in progress for the J Hawk 2H well and the fluid on containment exhibiting the elevated conductivity levels mentioned above, will be removed from the containment. |
2725148 | Primary Facility | 2018-05-01 | Routine/Complete Inspection | No Violations Noted | I performed a Routine Complete (RTNC) inspection of the Hawk well site on May 1, 2018. The wells associated with this site are as follows: 115-21650, 115-21651, 115-21652, 115-21653, 115-21654, 115-21655.
The wells were properly labeled. The cut slope had prior repairs performed, consisting of riprap places in areas of instability of the cut slope. There is now an area of instability above a previous repair wherein a vegetated section is currently slumping into the riprap stabilized area. (See photo) This could potentially be a violation of 102.22(a). It is suggested the issue be repaired as soon as possible to prevent accelerated erosion. Please inform the department within 7 days or upon completion of repairs. The fill slope is stable and well vegetated. There were no other areas of instability noted. There are no violations noted. |
2787218 | Primary Facility | 2018-10-09 | Routine/Complete Inspection | No Violations Noted | I performed a RTNC inspection of the Hawk well site.
The day was overcast but dry and in the upper 60s. The site footprint was approximately 107627 sq. ft. The wells were properly labeled. The well pad access road and pad surface was solid and stable. The fill slope was lush and heavily vegetated with no noticeable stability problems. The cut slope was vegetated but had rip rap stabilization along much of its length. It was stable however and where there was grass, it was lush and healthy. The tree plantings at the toe of the fill slope were healthy and viable. There were no erosional issues noted. There were no violations noted. |
For data sources see[9]