37-115-21351

Well Details

Well ID: 37-115-21351
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: Apolacon Township
Operator Name: REPSOL OIL & GAS USA LLC
Well Pad ID: 149733
Farm/Lease Name: REPINE 07 022 02 T 2H
License Status: Active
Spud Date: 2013-10-12
Permit Date: 2013-07-22
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.971306
Longitude: -76.0874

For data sources see[1][2][3]

Well History

Date Event
2013-07-22 New Permit Application
2013-09-03 Performed Spud Operation
2013-11-14 Drilling Completion
2014-03-16 Perforation
2014-03-28 Perforation
2014-03-28 Performed Stage 1 of Stimulation
2014-03-29 Perforation
2014-03-29 Performed Stage 2 of Stimulation
2014-03-29 Performed Stage 3 of Stimulation
2014-03-30 Perforation
2014-03-30 Performed Stage 4 of Stimulation
2014-03-30 Performed Stage 5 of Stimulation
2014-03-31 Perforation
2014-03-31 Performed Stage 6 of Stimulation
2014-04-01 Perforation
2014-04-01 Performed Stage 7 of Stimulation
2014-04-01 Performed Stage 8 of Stimulation
2014-04-02 Perforation
2014-04-02 Performed Stage 10 of Stimulation
2014-04-02 Performed Stage 9 of Stimulation
2014-04-03 Perforation
2014-04-03 Performed Stage 11 of Stimulation
2014-04-03 Performed Stage 12 of Stimulation
2014-04-04 Performed Stage 13 of Stimulation
2019-01-11 Deviated

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2014-04-04 2014-04-04 5,686 3,935,820 26,000

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 AQUCAR DB 5 (Water Treatment Microbiocide) Trican Biocide Sodium Bromide 7647-15-6 1.5 0.000397 162.539
Dibromoacetonitrile 3252-43-5 0.5 0.000132 54.1796
Polyethylene glycol 25322-68-3 65.2 0.017263 7065.02
2,2-dibromo-3-nitrilopropionamide 10222-01-2 5 0.001324 541.796
FEAC-20 (Iron Control) Trican Iron Control Citric acid 77-92-9 30 0.000924 378.147
Acetic acid 64-19-7 45 0.001386 567.22
Water Customer Carrier Water 7732-18-5 100 80.2597 32,846,000.0
3 1/2% HCL Trican Carrier Hydrochloric acid 7647-01-0 3.5 0.014274 5841.78
100 Mesh, Bulk (over 20K lbs)* Trican Proppant Crystalline silica: Quartz (SiO2) 14808-60-7 100 6.76995 2,770,580.0
7 1/2% HCL Trican Carrier Hydrochloric acid 7647-01-0 7.5 0.009517 3894.76
Other Chemicals Alkyloxypolyethylene oxyethanol 84133-50-6 0 0 0
Acrylamide 79-06-1 0 0 0
Ammonium Acrylate 10604-69-0 0 0 0
Trade Secret Proprietary 0 0 0
Nonionic Surfactant Proprietary 0 0 0
Sorbitol Tetraoleate 61723-83-9 0 0 0
Water 7732-18-5 0 0 0
Isopropanol 67-63-0 0 0 0
Polyethylene glycol monooleate 9004-96-0 0 0 0
Sorbitan monooleate 1338-43-8 0 0 0
Anionic polyacrylamide copolymer Proprietary 0 0 0
Acrylamide P/W acrylic acid ammonium salt 26100-47-0 0 0 0
LSI-21 (Scale Inhibitor) Trican Scale Inhibitor Acrylic Polymer 28205-96-1 15 0.003884 1589.61
Sodium Salt of Phosphate Ester 68131-72-6 15 0.003884 1589.61
White 40/70 Trican Proppant Crystalline silica: Quartz (SiO2) 14808-60-7 100 7.68143 3,143,600.0
AI-7NR (Acid Inhibitor) Trican Acid Inhibitor Prop-2-yn-1-ol 107-19-7 1 0.00001300 5.34106
FR-8 Trican Friction Reducer Petroleum distillates, hydrotreated heavy paraffinic 64742-54-7 8 0.003954 1618.04
Mineral oil/ light hydrotreated pet. distillate 64742-47-8 28 0.013838 5663.14
Ammonium Chloride 12125-02-9 1.5 0.000741 303.383
Petroleum distillates, dewaxed heavy paraffinic 64742-65-0 8 0.003954 1618.04
White 30/50 Trican Proppant Crystalline silica: Quartz (SiO2) 14808-60-7 100 4.64805 1,902,200.0

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2014-03-28 1 White 3,209,409 7,630 8,586
2014-03-29 2 White 3,209,409 7,602 8,799
2014-03-29 3 White 3,209,409 7,562 8,743
2014-03-30 4 White 3,209,409 7,324 8,786
2014-03-30 5 White 3,209,409 7,349 8,787
2014-03-31 6 White 3,209,409 7,356 8,533
2014-04-01 7 White 3,209,409 7,465 8,576
2014-04-01 8 White 3,209,409 7,346 8,882
2014-04-02 9 White 3,209,409 7,050 8,497
2014-04-02 10 White 3,209,409 6,878 8,383
2014-04-03 11 White 3,209,409 7,136 8,399
2014-04-03 12 White 3,209,409 6,963 8,118
2014-04-04 13 White 3,209,409 6,785 8,293

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2013 REPSOL OIL & GAS USA LLC 0.00 0 0.00 0 0.00 0
2014 REPSOL OIL & GAS USA LLC 175,443.60 24 0.00 0 0.00 0
2015 REPSOL OIL & GAS USA LLC 1,271,250.40 344 0.00 0 0.00 0
2016 REPSOL OIL & GAS USA LLC 920,972.20 359 0.00 0 0.00 0
2017 REPSOL OIL & GAS USA LLC 618,220.80 280 0.00 0 0.00 0
2018 REPSOL OIL & GAS USA LLC 565,640.70 323 0.00 0 0.00 0
2019 REPSOL OIL & GAS USA LLC 448,414.90 365 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2013 REPSOL OIL & GAS USA LLC Drill Cuttings 1,098.60 Tons LANDFILL 8-0728-0004/013
2014 REPSOL OIL & GAS USA LLC Fracing Fluid Waste 67.30 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2014 REPSOL OIL & GAS USA LLC Fracing Fluid Waste 100.90 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2014 REPSOL OIL & GAS USA LLC Fracing Fluid Waste 10,043.63 Bbl REUSE OTHER THAN ROAD SPREADING
2014 REPSOL OIL & GAS USA LLC Produced Fluid 19.53 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2015 REPSOL OIL & GAS USA LLC Produced Fluid 784.28 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2015 REPSOL OIL & GAS USA LLC Produced Fluid 929.27 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2015 REPSOL OIL & GAS USA LLC Produced Fluid 2,099.73 Bbl REUSE OTHER THAN ROAD SPREADING
2016 REPSOL OIL & GAS USA LLC Soil Contaminated by Oil 0.01 Tons RESIDUAL WASTE TRANSFER FACILITY 101611
2016 REPSOL OIL & GAS USA LLC Soil Contaminated by Oil & Gas Related Spills 0.01 Tons RESIDUAL WASTE TRANSFER FACILITY 101611
2016 REPSOL OIL & GAS USA LLC Produced Fluid 44.98 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2016 REPSOL OIL & GAS USA LLC Produced Fluid 931.13 Bbl REUSE OTHER THAN ROAD SPREADING
2017 REPSOL OIL & GAS USA LLC Produced Fluid 869.46 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2017 REPSOL OIL & GAS USA LLC Other Oil & Gas Wastes 120.00 Bbl REUSE (AT WELL PAD)
2017 REPSOL OIL & GAS USA LLC Produced Fluid 2,208.73 Bbl REUSE (AT WELL PAD)
2017 REPSOL OIL & GAS USA LLC Produced Fluid 30.89 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2017 REPSOL OIL & GAS USA LLC Synthetic Liner Materials 15.88 Tons LANDFILL 8-0728-0004/013
2018 REPSOL OIL & GAS USA LLC Soil Contaminated by Oil & Gas Related Spills 0.05 Tons RESIDUAL WASTE TRANSFER FACILITY 101611
2018 REPSOL OIL & GAS USA LLC Produced Fluid 1,146.94 Bbl REUSE (AT WELL PAD)
2018 REPSOL OIL & GAS USA LLC Soil Contaminated by Oil 0.05 Tons RESIDUAL WASTE TRANSFER FACILITY 101611
2018 REPSOL OIL & GAS USA LLC Produced Fluid 813.37 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018 REPSOL OIL & GAS USA LLC Produced Fluid 116.86 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2018 REPSOL OIL & GAS USA LLC Waste Water Treatment Sludge 0.04 Tons RESIDUAL WASTE TRANSFER FACILITY 101611
2019 REPSOL OIL & GAS USA LLC Produced Fluid 22.09 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2019 REPSOL OIL & GAS USA LLC Produced Fluid 9.17 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2019 REPSOL OIL & GAS USA LLC Other Oil & Gas Wastes 38.38 Bbl REUSE (AT WELL PAD)
2019 REPSOL OIL & GAS USA LLC Produced Fluid 193.69 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2019 REPSOL OIL & GAS USA LLC Produced Fluid 414.72 Bbl REUSE (AT WELL PAD)

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2202641 Primary Facility 2013-08-14 Routine/Complete Inspection Violation(s) Noted . A review of our records indicate that the required minimum 3 day notification for bulk earth disturbance activity after the installation of all perimeter sediment BMP’s was not received. Paragraph 16 of your permits standard conditions clearly states that this is to be done. A review of your construction sequence also clearly states the condition. This inspection qualifies as the required pre-operational inspection.
2235856 Primary Facility 2014-01-07 Routine/Complete Inspection No Violations Noted
2247623 Primary Facility 2014-02-21 Routine/Complete Inspection No Violations Noted Unable to access location due to snow.
2340897 Primary Facility 2015-01-27 Routine/Complete Inspection No Violations Noted The Department was on site on January 27, 2015 to conduct a Routine Complete Inspection of Talisman's Repine Compressor Station. The wells associated with this site are:
2400660 Primary Facility 2015-08-20 Routine/Complete Inspection No Violations Noted
2451873 Primary Facility 2016-02-01 Routine/Complete Inspection No Violations Noted The Department was on site on 2/1/2016 to conduct a Routine Complete Inspection of Talisman's Repine Well Pad (ESG13-115-0059). The wells associated with this site are:

2H 115-21351 3H 115-21352 4H 115-21353


There was adequate vegetation throughout the site and there were no erosional issues apparent at this time.

There are no violations. If there are any questions please feel free to contact me.

2467830 Primary Facility 2016-03-16 Routine/Partial Inspection No Violations Noted The Department was on site to conduct a Routine Partial Inspection of the Repine Well Site located in Apolacon Township, Susquehanna County. At the time of the inspection, it appeared as though the well site met temporary stabilization requirements.
2500982 Primary Facility 2016-07-13 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 10:45a.m., the cellar was empty, there was cement between the (20x13) annulus with no gas detected and there was cement between the (13x9) annulus with no gas detected. The (9x5) vent pipe was open and venting into the atmosphere with gas detected at 100% LEL and 100% methane with no measurable flow. There was 574psi on the production casing and 407psi on the production tubing. I took a walk around the location and everything looked OK.

I left the site at 11:20a.m.

2534677 Primary Facility 2016-11-01 Routine/Complete Inspection No Violations Noted The Department was on site on 2/1/2016 to conduct a Routine Complete Inspection of Talisman's Repine Well Pad (ESG13-115-0059). The wells associated with this site are:

2H 115-21351 3H 115-21352 4H 115-21353

The well pad was stable, but due to recent heavy rainfall, the area covered by a bermed liner surrounding the wellheads had about 4 inches of water covering the surface. There was no bubbling from the well cellars apparent, and the water was contained. It would be recommended to vacuum the water from this area to prevent any potential problems. There was adequate vegetation throughout the site and there were no erosional issues apparent at this time.

There are no violations. If there are any questions please feel free to contact me

2588124 Primary Facility 2017-04-13 Routine/Complete Inspection No Violations Noted Arrived at the site at 11:35. The weather conditions were partly sunny with temperatures in the upper 40's. Repsol submitted a notification to the Department in Greenport (esubmissions) on 4/11/17 at 4:10 PM for Notice prior to installation of a modular storage structure per 78.56(a)(4) (unconventional wells). The notice indicated the modular storage structure (DYNA tank) construction/ installation would commence on 4/11/17. The following comments were generated upon submission of the notification. " This proposed date does not meet the regulation’s 3 business day advance notice requirement. See the date provided for the question: "* Date and time construction/installation is to begin" If you wish to send this notification to DEP anyway, you may use the Submit button at the bottom of this page to confirm this alert and send. I was accompanied by Frank Hoehle, DEP O&G WQS of the Scranton District Office. We met with Shaun Smith, site company man of Repsol. Mr. Smith stated the following in reference to sit
2590057 Primary Facility 2017-05-02 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 11:00a.m.

The cellar was about a quarter full of water with no bubbling noticed. There was cement at the (20x13) annulus with water setting on top with no bubbling noticed. There was cement at the (13x9) annulus with no gas detected. The (9x5) annulus vent pipe was open and venting into the atmosphere with gas detected at 100% LEL and 100% methane. There was 540psi on the production casing and 336psi on the production line. I took a walk around the location and there were no obvious concerns noticed. I left the site at 11:40a.m.

2620100 Primary Facility 2017-07-18 Routine/Complete Inspection No Violations Noted I arrived at the site at 11:33. I was accompanied by Frank Hoehle, PADEP O&G WQS during the inspection. The weather conditions were partly cloudy skies with a light breeze, very warm and humid with temperatures in the low to mid 80's. Repsol submitted a stimulation notification to the Department on 7/6/17. The notification indicated that stimulation (hydraulic fracturing) of the wells would commence on 7/12/17 at 6 AM. We met with Dave Coxhead, site safety man of REM Security and Dell Gunn, site company man and completions consultant of Repsol. Mr. Gunn and Mr. Coxhead stated the following in reference to site activities. "Frac operations commenced on 7/14/17. The 1H well is in the process of being stimulated in the 5th of the 36th stage. Zipper frac operations are in progress. The 1H, 4H, 5H and 7H wells will be stimulated. The 2H and 3H wells were in production, but are currently shut in". The Department left the site at 12:41.
2635923 Primary Facility 2017-08-30 Routine/Complete Inspection No Violations Noted
2646387 Primary Facility 2017-10-11 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. There was a 500bbl tank on containment and the containment appeared to be in good condition. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2686308 Primary Facility 2018-01-23 Routine/Complete Inspection No Violations Noted I inspected the Repine T well site on Jan 23, 2018. The site access road was paved and in good shape. The site surface had a lot of standing water due to recent heavy rains and snowmelt. Despite the water, the pad surface was solid. The slopes around the site were well vegetated and stable. The wells were all properly labeled. The area where a large water tank had been (now removed) was well graded and had no issues. There were no erosional issues noted.

The wells associated with this site are as follows: 115-21351 115-21352 115-22146 115-22147 115-22148 115-22149

2710187 Primary Facility 2018-03-22 Routine/Complete Inspection No Violations Noted I performed a Routine Complete inspection of the Repine well pad. Work was being performed involving the sand separators on the well site. The Access road was paved and plowed, and the pad surface was solid and stable. The fill slope and area surrounding the pad and access road were all vegetated, visible through the snow cover. There were no erosional issues observed. The wells were properly labeled.

The wells associated with this site were as follows: 115-21351 115-21352 115-22146 115-22147 115-22148 115-22149

There were no violations noted.

2752806 Primary Facility 2018-07-17 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. There was water 4.5' below grade in the cellar with no bubbling noticed and there was no gas detected in the remainder of the cellar. There was a 500bbl tank on containment and the containment appeared to be in good condition. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2760836 Primary Facility 2018-08-06 Routine/Complete Inspection No Violations Noted I performed a RTNC inspection of the Repine well site. The wells associated with this site are as follows: 115-21351, 115-21352, 115-22146, 115-22147, 115-22148, 115-22149.

The wells were properly labeled. (Photo 1). The well cellars were full of water due to recent rains. None appeared to be bubbling at the time of inspection.

The access road was paved and the macadam was in good shape. There was no erosional issues observed along the access road ditch.

The cut slope and topsoil pile were stable and well vegetated. (Photo 2). The fill slope was stable and well vegetated also. (Photo 3). The grasses were perennial. There was no slumping or erosional issues observed at the time of inspection.

The pad surface was well graded and stable.

There were no violations noted.

2763189 Primary Facility 2018-08-13 Routine/Complete Inspection No Violations Noted While on site for a reported release I performed a perfunctory e & s inspection, as I was recently at the site. There were no erosional issues noted, and all slopes appeared stable despite the monsoon-like rains the area was experiencing.

The wells were properly labeled.

There were no violations noted.

2853977 Primary Facility 2019-03-14 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. The cellar was empty with cement between the (20x13) and (13x9) annuli and there was no gas detected with a MSA Altair 5X multi gas detector that was calibrated on 3/13/19. The (9x5) annulus was venting to the atmosphere, see well information for gas show. There was a 500bbl tank about 3/4 full of fluid on containment and the containment appeared to be in good condition. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2202641 677507 08/14/2013 2013-08-14 402CSL B - Failure to meet requirements of permit, rules and regulations, or order of DEP. Environmental Health & Safety

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
677507 302005 NOV - Notice of Violation

For data sources see[9]

References