If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-115-21241 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.826392,"lon":-75.8513,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Susquehanna | |
Municipality: Bridgewater Township | |
Operator Name: CABOT OIL & GAS CORP | |
Well Pad ID: 145117 | |
Farm/Lease Name: CASTROGIOVANNI A 1 | |
License Status: | |
Spud Date: | |
Permit Date: 2013-04-25 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.826392 | |
Longitude: -75.8513 |
Date | Event |
---|---|
2013-04-25 | New Permit Application |
2013-05-24 | Performed Spud Operation |
2013-09-15 | Drilling Completion |
2013-09-21 | Perforation |
2013-09-27 | Performed Stimulation |
2014-03-11 | DEVIATED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2013-09-26 | 2013-10-06 | 6,560 | 5,337,740 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Alpha 1427 | Baker Hughes | Biocide | Glutaraldehyde | 111-30-8 | 30 | 0.009482 | 4811.63 |
Quaternary Ammonium Compound | 68424-85-1 | 5 | 0.0015803 | 801.938 | ||||
Didecyl Dimethyl Ammonium Chloride | 7173-51-5 | 10 | 0.0031607 | 1603.88 | ||||
Ethanol | 64-17-5 | 5 | 0.0015803 | 801.938 | ||||
HCl, 10.1 - 15% | Baker Hughes | Acidizing | Water | 7732-18-5 | 85 | 0.485802 | 246520 | |
Hydrochloric Acid | 7647-01-0 | 15 | 0.0857298 | 43503.5 | ||||
Other Chemicals | Formaldehyde | 50-00-0 | 0 | 0.00000860 | 4.35 | |||
Sorbitan Monooleate | Trade Secret | 0 | 0.0043522 | 2208.53 | ||||
Salt | Trade Secret | 0 | 0.0043522 | 2208.53 | ||||
Sodium Chloride | 7647-14-5 | 0 | 0.00000450 | 2.3039 | ||||
Polyacrylate | Trade Secret | 0 | 0.0030268 | 1535.92 | ||||
Poly (acrylamide-co-acrylic acid) | Trade Secret | 0 | 0.0261134 | 13251.2 | ||||
Potassium Chloride | 7447-40-7 | 0 | 0.00000760 | 3.8398 | ||||
Ethoxylated Alcohol | Trade Secret | 0 | 0.0017409 | 883.414 | ||||
Water | 7732-18-5 | 0 | 0.0706829 | 35868 | ||||
Modified Thiorea Polymer | 68527-49-1 | 0 | 0.00006000 | 30.45 | ||||
Hydrochloric Acid | 7647-01-0 | 0 | 0.00000860 | 4.35 | ||||
Sand, White, 100 mesh | Baker Hughes | Proppant | Crystalline Silica (Quartz) | 14808-60-7 | 100 | 0.600454 | 304700 | |
FRW-18 | Baker Hughes | Friction Reducer | Petroleum Distillates | 64742-47-8 | 30 | 0.0261134 | 13251.2 | |
Water | Operator | Carrier | Water | 7732-18-5 | 100 | 87.7034 | 44,505,000.0 | |
Ferrotrol 300L | Baker Hughes | Iron Control | Citric Acid | 77-92-9 | 60 | 0.0007454 | 378.26 | |
CI-14 | Baker Hughes | Corrosion Inhibitor | Methanol | 67-56-1 | 100 | 0.0008572 | 435 | |
Fatty Acids | Trade Secret | 10 | 0.00008570 | 43.5 | ||||
Polyoxyalkylenes | Trade Secret | 30 | 0.0002572 | 130.5 | ||||
Propargyl Alcohol | 107-19-7 | 5 | 0.00004290 | 21.75 | ||||
Olefin | Trade Secret | 5 | 0.00004290 | 21.75 | ||||
Sand, White, 40/70 | Baker Hughes | Proppant | Crystalline Silica (Quartz) | 14808-60-7 | 100 | 10.965 | 5,564,200.0 | |
Scaletrol 720 | Baker Hughes | Scale Inhibitor | Calcium Chloride | 10043-52-4 | 5 | 0.0007567 | 383.981 | |
Ethylene Glycol | 107-21-1 | 30 | 0.0045401 | 2303.88 |
For data sources see[5]
Stimulation Date | Phase Number | Chemical Agent | Volume (gal) | Treating Pressure (psi) | Breakdown Pressure (psi) |
---|---|---|---|---|---|
2013-09-27 | 0 | 0 | 0 |
For data sources see[6]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2013 | CABOT OIL & GAS CORP | 600,704.40 | 62 | 0.00 | 0 | 0.00 | 0 |
2014 | CABOT OIL & GAS CORP | 2,069,597.04 | 362 | 0.00 | 0 | 0.00 | 0 |
2015 | CABOT OIL & GAS CORP | 980,774.24 | 365 | 0.00 | 0 | 0.00 | 0 |
2016 | CABOT OIL & GAS CORP | 936,400.44 | 366 | 0.00 | 0 | 0.00 | 0 |
2017 | CABOT OIL & GAS CORP | 620,768.32 | 359 | 0.00 | 0 | 0.00 | 0 |
2018 | CABOT OIL & GAS CORP | 501,463.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2019 | CABOT OIL & GAS CORP | 398,602.00 | 365 | 0.00 | 0 | 0.00 | 0 |
For data sources see[7]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2013 | CABOT OIL & GAS CORP | Drilling Fluid Waste | 1,000.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2013 | CABOT OIL & GAS CORP | Produced Fluid | 10,120.96 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2013 | CABOT OIL & GAS CORP | Drill Cuttings | 748.94 Tons | LANDFILL | 101247 |
2013 | CABOT OIL & GAS CORP | Drill Cuttings | 517.97 Tons | LANDFILL | THR029 |
2013 | CABOT OIL & GAS CORP | Drilling Fluid Waste | 138.25 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE001 |
2013 | CABOT OIL & GAS CORP | Produced Fluid | 121.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE001 |
2013 | CABOT OIL & GAS CORP | Fracing Fluid Waste | 6,078.24 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2013 | CABOT OIL & GAS CORP | Fracing Fluid Waste | 257.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE001 |
2014 | CABOT OIL & GAS CORP | Produced Fluid | 2,756.16 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2014 | CABOT OIL & GAS CORP | Produced Fluid | 69.75 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE001 |
2015 | CABOT OIL & GAS CORP | Produced Fluid | 519.54 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2015 | CABOT OIL & GAS CORP | Produced Fluid | 20.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE001 |
2016 | CABOT OIL & GAS CORP | Produced Fluid | 131.32 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2016 | CABOT OIL & GAS CORP | Produced Fluid | 191.36 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2017 | CABOT OIL & GAS CORP | Synthetic Liner Materials | 0.69 Tons | LANDFILL | 101247 |
2017 | CABOT OIL & GAS CORP | Produced Fluid | 110.73 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2017 | CABOT OIL & GAS CORP | Produced Fluid | 206.89 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2018 | CABOT OIL & GAS CORP | Produced Fluid | 6.08 Bbl | REUSE (AT WELL PAD) | |
2018 | CABOT OIL & GAS CORP | Produced Fluid | 184.73 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2018 | CABOT OIL & GAS CORP | Produced Fluid | 59.62 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2019 | CABOT OIL & GAS CORP | Produced Fluid | 240.27 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
For data sources see[8]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2179919 | Primary Facility | 2013-06-12 | Drilling/Alteration | No Violations Noted | Spudder rig on location |
2181851 | Primary Facility | 2013-05-16 | Routine/Partial Inspection | No Violations Noted | pre-operations |
2367119 | Primary Facility | 2015-05-05 | Routine/Complete Inspection | No Violations Noted | |
2438279 | Primary Facility | 2016-01-06 | Routine/Complete Inspection | No Violations Noted | At time of inspection, arrived on site at 11:55 a.m., the cellar had ice at the bottom, the (13x9) vent pipe was open and venting to a tank, the (9x5) vent pipe was open and venting to a tank, there was 579psi on the production casing. I took a walk around the location and everything looked OK.
I left the site at 12:35 p.m. |
2439129 | Primary Facility | 2015-09-07 | Routine/Complete Inspection | No Violations Noted | Inspection associated with the NOT inspection of the Bridgewater pipeline. No issues observed at the time of the inspection. |
2538851 | Primary Facility | 2016-11-22 | Routine/Complete Inspection | No Violations Noted | At time of inspection, arrived on site at 11:45a.m., the cellar had water and snow at the bottom with no bubbling noticed. The (13x9) vent pipe was open and venting into the production tank, the (9x5) vent pipe was open and venting into the production tank. There was 489psi on the production casing. I took a walk around the location and there were no obvious concerns noticed.
I left the site at 12:25p.m. |
2560925 | Primary Facility | 2017-02-06 | Routine/Complete Inspection | No Violations Noted | The Department was on site to conduct a Routine Complete Inspection of the Castrogiovanni well site. At the time of the Department's arrival, a well tender was on site. I reviewed the E&S Inspection Log which showed that Sam Wiernusz conducted the most recent inspection which was listed as a Post Precipitation Inspection on 2/2/17. The well site was mostly snow covered. No obvious issues were noted. |
2626903 | Primary Facility | 2017-08-16 | Routine/Complete Inspection | No Violations Noted | At time of inspection, arrived on site at 11:30a.m.
The cellar had water at the bottom with no bubbling noticed. The (13x9) annulus vent pipe was open and venting into a small plastic tank, the (9x5) annulus vent pipe was open and venting into a small plastic tank. All the annulus vent pipes were connected to one pipe going into the same tank. There was 540psi on the production casing. I took a walk around the location and there were no obvious concerns noticed. I left the site at 12:15p.m. |
2640613 | Primary Facility | 2017-09-27 | Administrative/File Review | No Violations Noted | |
2640623 | Primary Facility | 2017-08-16 | Routine/Complete Inspection | No Violations Noted | The Department was on site to conduct a Routine Complete Inspection. The E&S Inspection Log stated that Scott Rockwell (TEC) conducted the most recent inspection on 8/16/17. Currently the 1H, 5H, 4H, and 8H wells are present however the Department was unable to locate well tags. The Department contacted Steve Watson concerning this issue and requested a return call. |
2737148 | Primary Facility | 2018-06-04 | Routine/Complete Inspection | No Violations Noted | At time of inspection.
The well was in production. There was water 5' below grade with no bubbling noticed and there was no gas detected in the remainder of the cellar. The (13x9) and (9x5) annuli vent pipes were connected together and going to the same tank. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted. |
2776786 | Primary Facility | 2018-09-18 | Routine/Complete Inspection | No Violations Noted | I performed a Routine inspection of the Castrogiovanni well site. It was sunny, following some heavy rains.
The site was compact (104,999 sq. ft.). The access road and well pad surface were stable and solid. The cut slope was well vegetated, above 70% perennial vegetation, except for a small section where the ground was too rocky to provide for heavy vegetative cover. The fill slope was well vegetated and the surrounding area was involved in active agriculture (hayfield, corn). There was a row of evergreen trees planted along the fill slope, and all looked healthy. The entire area was solid and stable with good vegetative cover. There were no violations noted. |
2833559 | Primary Facility | 2019-01-30 | Routine/Complete Inspection | No Violations Noted | At time of inspection.
The well was in production. There was snow and ice 3' below grade in the cellar and there was no gas detected. The (13x9) and (9x5) annuli vent pipes were connected together and going to the same poly vent tank. There was gas detected at the poly vent tank with a MSA Altair 5X multi gas detector that was calibrated on 1/2/19. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted. |
For data sources see[9]