37-115-21030

Well Details

Well ID: 37-115-21030
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: Harford Township
Operator Name: CABOT OIL & GAS CORP
Well Pad ID: 146094
Farm/Lease Name: EMPET D 1
License Status:
Spud Date:
Permit Date: 2012-11-06
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.739025
Longitude: -75.710397

For data sources see[1][2][3]

Well History

Date Event
2012-11-06 New Permit Application
2013-01-15 Performed Spud Operation
2013-03-23 Drilling Completion
2013-05-09 Perforation
2013-05-23 Performed Stimulation
2013-12-27 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2013-05-22 2013-06-09 7,093 6,204,530

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 FRW-200 FTSI Friction reducer Alcohols (C12-C16), ethoxylated 68551-12-2 4 0.0029 0
Copolymer of acrylamide and sodium acrylate 25987-30-8 33 0.02392 0
Alkyloxypolyethyleneoxyethanol 84133-50-6 1 0.00072 0
Polyethylene glycol monooleate 9004-96-0 3 0.00217 0
Acrylamide 79-06-1 0.1 0.00007000 0
Petroleum distillate hydrotreated light 64742-47-8 26 0.01885 0
Acrylamide P/W acrylic acid, ammonium salt 26100-47-0 25 0.0812 0
Surfactant propriety 7 0.00507 0
Alcohols (C10-C16), ethoxylated 68002-97-1 4 0.0029 0
Sorbitan Monooleate 1338-43-8 3 0.00217 0
Alcohols (C12-C14), ethoxylated 68439-50-9 4 0.0029 0
Water 7732-18-5 48 0.0348 0
Proprietary Component propriety 1.5 0.00109 0
Ammonium Chloride 12125-02-9 12 0.0087 0
Sorbitol Tetraoleate 61723-83-9 2 0.00145 0
Ammonium Acrylate 10604-69-0 0.5 0.00036 0
Water Operator Carrier Water 7732-18-5 100 88.1828 0
BIO-3240 FTSI Biocide Water 7732-18-5 55 0.01763 0
Dazomet (Tetrahydro-3, 5-dimethyl-2H-1,
3, 5-thiadiazine-2-thione.
533-74-4 24 0.00769 0
Sodium Hydroxide 1310-73-2 23 0.00737 0
CS-500 SI FTSI Scale inhibitor Ethylene glycol 107-21-1 10 0.00317 0
Water 7732-18-5 55 0.01743 0
Acrylic Polymer propriety 0 0 0
Sodium Polyacrylate 9003-04-7 5 0.00158 0
Sodium chloride 7647-14-5 6 0.0019 0
100 Mesh Sand FTSI Proppant 100 Mesh Sand na 100 0.5789 0
FE-100L FTSI Iron control Citric acid 77-92-9 55 0.00094 0
Water 7732-18-5 60 0.00102 0
40/70 White FTSI Proppant 40/70 White na 100 10.5612 0
Hydrochloric Acid (HCl) FTSI Acid Hydrogen Chloride 7647-01-0 15 0.08074 0
Water 7732-18-5 85 0.45753 0
CI-150 FTSI Acid Corrosion Inhibitor Aromatic aldehyde propriety 10 0.0001 0
Ethylene Glycol 107-21-1 30 0.00029 0
Aliphatic alcohol propriety 0.1 0.00001000 0
Fatty Acid propriety 0.1 0.00001000 0
Organic amine resin salt propriety 30 0.00029 0
Fatty Acid Salt propriety 0.1 0.00001000 0
Dimethylformamide 68-12-2 10 0.0001 0
Water 7732-18-5 5 0.00005000 0
Diethylene glycol 111-46-6 1 0.00001000 0
Alkylene Oxide Block Polymer propriety 10 0.0001 0
Isopropanol 67-63-0 30 0.00029 0
Quaternary ammonium compound propriety 10 0.0001 0

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2013-05-23 0 0 0

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2013 CABOT OIL & GAS CORP 2,360,610.74 192 0.00 0 0.00 0
2014 CABOT OIL & GAS CORP 2,303,751.82 355 0.00 0 0.00 0
2015 CABOT OIL & GAS CORP 1,341,861.13 365 0.00 0 0.00 0
2016 CABOT OIL & GAS CORP 1,070,227.23 366 0.00 0 0.00 0
2017 CABOT OIL & GAS CORP 851,318.80 365 0.00 0 0.00 0
2018 CABOT OIL & GAS CORP 614,946.00 302 0.00 0 0.00 0
2019 CABOT OIL & GAS CORP 115,865.00 115 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2013 CABOT OIL & GAS CORP Fracing Fluid Waste 15,948.98 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NE002
2013 CABOT OIL & GAS CORP Fracing Fluid Waste 353.25 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NE001
2013 CABOT OIL & GAS CORP Produced Fluid 6,114.98 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2013 CABOT OIL & GAS CORP Drill Cuttings 655.60 Tons LANDFILL 101247
2013 CABOT OIL & GAS CORP Drilling Fluid Waste 1,967.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NE002
2013 CABOT OIL & GAS CORP Drill Cuttings 377.00 Tons LANDFILL THR029
2013 CABOT OIL & GAS CORP Produced Fluid 60.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2014 CABOT OIL & GAS CORP Produced Fluid 1,538.57 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2015 CABOT OIL & GAS CORP Produced Fluid 624.55 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2015 CABOT OIL & GAS CORP Produced Fluid 7.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2016 CABOT OIL & GAS CORP Produced Fluid 211.84 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2016 CABOT OIL & GAS CORP Produced Fluid 205.49 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2017 CABOT OIL & GAS CORP Produced Fluid 36.44 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2017 CABOT OIL & GAS CORP Produced Fluid 116.25 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE004
2017 CABOT OIL & GAS CORP Produced Fluid 25.62 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2018 CABOT OIL & GAS CORP Produced Fluid 165.91 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2018 CABOT OIL & GAS CORP Produced Fluid 63.15 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2019 CABOT OIL & GAS CORP Produced Fluid 152.61 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2019 CABOT OIL & GAS CORP Waste Water Treatment Sludge 3.45 Tons REUSE (AT WELL PAD)
2019 CABOT OIL & GAS CORP Produced Fluid 288.35 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE004

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2142987 Primary Facility 2012-12-18 Routine/Complete Inspection No Violations Noted
2144109 Primary Facility 2013-02-28 Drilling/Alteration No Violations Noted conductor has been set. Patterson 538 curently drilling Empet 2H. Will be drilling 1H next. No violations observed.
2164219 Primary Facility 2013-05-07 Routine/Complete Inspection No Violations Noted Crews onsite setting up equipment to perform pressure tests.
2476156 Primary Facility 2016-04-19 Routine/Complete Inspection No Violations Noted
2500369 Primary Facility 2016-07-07 Routine/Complete Inspection No Violations Noted
2579210 Primary Facility 2017-04-04 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 11:25a.m.

The cellar had water at the bottom with no bubbling noticed. The (13x9) annulus vent pipe was open and venting to the production tank, the (9x5) annulus vent pipe was open and venting to the production tank. There was 499psi on the production casing. I took a walk around the location and there were no obvious concerns noticed. I left the site at 12:05p.m.

2673197 Primary Facility 2017-12-20 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. The cellar had water below the conductor pipe and there was no gas detected in the cellar. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2769364 Primary Facility 2018-08-30 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. The cellar was empty and there was no gas detected. The (13x9) and (9x5) annuli vent pipes were connected together and going to the same production tank. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2830846 Primary Facility 2019-01-16 Incident- Response to Accident or Event No Violations Noted I arrived at the site at 9:43 in response to a report of staining discovered on the pad surface as Cabot was in the process of removing the secondary containment liner user for drilling operations. I was accompanied by Gene Rickard, DEP O&G WQS out of the Scranton District Office. The weather conditions are cloudy skies, cold, with light winds, and temperatures in the 30's. Cabot was in the process of rigging down the site. Precision Drilling Rig # 181 has recently demobilized from the site. Cabot submitting Drilling resumption After Break of 30 days or more notifications to the Department for the Empet 3H, 5H, 6H, 7H, 10H and 12H wells. The notifications were submitted on 12/4/18, 12/13/18, 12/14/18, and 12/15/18. The 1H, 2H, 4H, and 8H are the existing wells on the pad, but are currently shut in. The production equipment for these wells has been moved to the tank pad section of the site. We met with Eric Peterson, Drilling Environmental Health and Safety Consultant of Cabot Oil and Gas. Cabot was in
2847220 Primary Facility 2019-02-26 Routine/Complete Inspection No Violations Noted Today's inspection was conducted as a routine inspection. Overall the site appears to have good stabilization. No E&S issues identified. No violations noted.

For data sources see[9]

References