If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-115-20921 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.865542,"lon":-75.930408,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Susquehanna | |
Municipality: Forest Lake Township | |
Operator Name: BKV OPR LLC | |
Well Pad ID: 145320 | |
Farm/Lease Name: BUSH 4H | |
License Status: | |
Spud Date: | |
Permit Date: 2012-05-23 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.865542 | |
Longitude: -75.930408 |
Date | Event |
---|---|
2012-05-23 | New Permit Application |
2012-07-27 | Performed Spud Operation |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2013-07-07 | 2013-08-08 | 6,659 | 6,987,460 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | FRW-18 | Baker Hughes | Friction Reducer | Petroleum Distillates | 64742-47-8 | 30 | 0.0196097 | 13055 |
InFlo 250W | Baker Hughes | Surfactant | Methanol | 67-56-1 | 30 | 0.0002705 | 180.096 | |
2-Butoxyethanol | 111-76-2 | 5 | 0.00004510 | 30.0161 | ||||
Surfactants | Trade Secret | 80 | 0.0007214 | 480.257 | ||||
Other Chemicals | Hydrochloric Acid | 7647-01-0 | 0 | 0.00000780 | 5.22 | |||
Poly (acrylamide-co-acrylic acid) | Trade Secret | 0 | 0.0196097 | 13055 | ||||
Potassium Chloride | 7447-40-7 | 0 | 0.00000760 | 5.0404 | ||||
Sorbitan Monooleate | Trade Secret | 0 | 0.0032683 | 2175.83 | ||||
Polyacrylate | Trade Secret | 0 | 0.0030284 | 2016.15 | ||||
Salt | Trade Secret | 0 | 0.0032683 | 2175.83 | ||||
Formaldehyde | 50-00-0 | 0 | 0.00000780 | 5.22 | ||||
Ethoxylated Alcohol | Trade Secret | 0 | 0.0013073 | 870.334 | ||||
Sodium Chloride | 7647-14-5 | 0 | 0.00000450 | 3.0242 | ||||
Modified Thiorea Polymer | 68527-49-1 | 0 | 0.00005490 | 36.54 | ||||
Water | 7732-18-5 | 0 | 0.0561771 | 37399.4 | ||||
Scaletrol 720 | Baker Hughes | Scale Inhibitor | Calcium Chloride | 10043-52-4 | 5 | 0.0007571 | 504.037 | |
Ethylene Glycol | 107-21-1 | 30 | 0.0045426 | 3024.22 | ||||
Ferrotrol 300L | Baker Hughes | Iron Control | Citric Acid | 77-92-9 | 60 | 0.0020454 | 1361.74 | |
Alpha 1427 | Baker Hughes | Biocide | Didecyl Dimethyl Ammonium Chloride | 7173-51-5 | 10 | 0.0022633 | 1506.75 | |
Glutaraldehyde | 111-30-8 | 30 | 0.0067898 | 4520.25 | ||||
Quaternary Ammonium Compound | 68424-85-1 | 5 | 0.0011316 | 753.375 | ||||
Ethanol | 64-17-5 | 5 | 0.0011316 | 753.375 | ||||
CI-14 | Baker Hughes | Corrosion Inhibitor | Polyoxyalkylenes | Trade Secret | 30 | 0.0002352 | 156.6 | |
Propargyl Alcohol | 107-19-7 | 5 | 0.00003920 | 26.1 | ||||
Fatty Acids | Trade Secret | 10 | 0.00007840 | 52.2 | ||||
Olefin | Trade Secret | 5 | 0.00003920 | 26.1 | ||||
Methanol | 67-56-1 | 100 | 0.0007841 | 522 | ||||
Water | Operator | Carrier | Water | 7732-18-5 | 100 | 87.5115 | 58,260,000.0 | |
Sand, White, 100 mesh | Baker Hughes | Proppant | Crystalline Silica (Quartz) | 14808-60-7 | 100 | 0.771621 | 513700 | |
Sand, White, 30/50 | Baker Hughes | Proppant | Crystalline Silica (Quartz) | 14808-60-7 | 100 | 6.01991 | 4,007,700.0 | |
HCl, 5.1 - 7.5% | Baker Hughes | Acidizing | Water | 7732-18-5 | 92.5 | 0.752205 | 500774 | |
Hydrochloric Acid | 7647-01-0 | 7.5 | 0.0609896 | 40603.3 | ||||
Sand, White, 40/70 | Baker Hughes | Proppant | Crystalline Silica (Quartz) | 14808-60-7 | 100 | 4.64039 | 3,089,300.0 | |
HCl, 10.1 - 15% | Baker Hughes | Acidizing | Hydrochloric Acid | 7647-01-0 | 15 | 0.0174256 | 11600.9 | |
Water | 7732-18-5 | 85 | 0.0987451 | 65738.7 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2012 | CARRIZO (MARCELLUS) LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2013 | CARRIZO (MARCELLUS) LLC | 214,333.00 | 109 | 0.00 | 0 | 0.00 | 0 |
2014 | CARRIZO (MARCELLUS) LLC | 1,694,337.66 | 351 | 0.00 | 0 | 0.00 | 0 |
2015 | CARRIZO (MARCELLUS) LLC | 613,889.65 | 243 | 0.00 | 0 | 0.00 | 0 |
2016 | CARRIZO (MARCELLUS) LLC | 830,810.91 | 303 | 0.00 | 0 | 0.00 | 0 |
2017 | CARRIZO (MARCELLUS) LLC | 902,933.10 | 355 | 0.00 | 0 | 0.00 | 0 |
2018 | BKV OPR LLC | 692,388.24 | 354 | 0.00 | 0 | 0.00 | 0 |
2019 | BKV OPR LLC | 653,864.93 | 363 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2012 | CARRIZO (MARCELLUS) LLC | Drill Cuttings | 303.87 Tons | LANDFILL | 301626 |
2012 | CARRIZO (MARCELLUS) LLC | Drill Cuttings | 80.84 Tons | LANDFILL | THR029 |
2013 | CARRIZO (MARCELLUS) LLC | Drill Cuttings | 788.00 Tons | LANDFILL | 301626 |
2013 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 246.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE003 |
2013 | CARRIZO (MARCELLUS) LLC | Drill Cuttings | 975.00 Tons | LANDFILL | THR029 |
2014 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 90.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE003 |
2014 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 423.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR119 |
2014 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 27,292.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
2014 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 371.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 7,330.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2015 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 267.14 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
2015 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 781.91 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE003 |
2015 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 351.24 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2015 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 1,394.53 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 214.90 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
2016 | CARRIZO (MARCELLUS) LLC | Other Oil & Gas Wastes | 11.95 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
2016 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 638.54 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
2016 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 591.02 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE003 |
2016 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 50.53 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2016 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 49.80 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2016 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 525.94 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE003 |
2016 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 117.19 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
2016 | CARRIZO (MARCELLUS) LLC | Other Oil & Gas Wastes | 11.95 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE003 |
2016 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 194.89 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2016 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 346.27 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2017 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 992.31 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2017 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 309.71 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2017 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 185.58 Bbl | REUSE (AT WELL PAD) | |
2017 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 604.68 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE003 |
2017 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 24.17 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2018 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 212.89 Bbl | REUSE (AT WELL PAD) | |
2018 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 88.40 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE003 |
2018 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 1,730.16 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2019 | BKV OPR LLC | Produced Fluid | 42.00 Bbl | REUSE (AT WELL PAD) | |
2019 | BKV OPR LLC | Produced Fluid | 483.17 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE003 |
2019 | BKV OPR LLC | Produced Fluid | 42.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR119 |
2019 | BKV OPR LLC | Produced Fluid | 1,249.20 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2097752 | Primary Facility | 2012-09-06 | Complaint Inspection | Pending | I met with the Company Man on site and requested to review the drilling logs for encounters with water during the drilling process. The topholes were in the process of being drilled. The surface and intermediate casings were drilled on the 3H, 4H, and 5H. Drilling of the 2H was to commence on 9/6/2012. |
2099646 | Primary Facility | 2012-08-31 | Drilling/Alteration | No Violations Noted | Walked site. Rigging up on well at time of inspection. Secondary containment in place and in good condition. Checked cellars, no issues observed. Fluid Technologies on site to solidify cuttings. Notifications received. Drilling top holes on 5 wells a this time. 20" conductor set at 56'bg. No violations observed at this time. |
2125259 | Primary Facility | 2012-12-05 | Routine/Complete Inspection | No Violations Noted | Well is currently in production. Well tag is in place. Cellar is open and full of standing water. No activity on site. Secondary containment in place. No violations oberved. |
2145628 | Primary Facility | 2013-03-05 | Drilling/Alteration | No Violations Noted | Nabors Rig M-61 on site. Currently drilling ahead on Bush 4H at depth of @ 6000’. Secondary containment in place and in good condition. Drillers log on site and up to date. Tagged cement at @5700’. Topholes previously drilled to KOP. No violations observed. |
2155249 | Primary Facility | 2013-04-10 | Follow-up Inspection | No Violations Noted | |
2155984 | Primary Facility | 2013-04-09 | Routine/Partial Inspection | No Violations Noted | |
2269071 | Primary Facility | 2014-04-25 | Routine/Complete Inspection | No Violations Noted | All wells on location have been completed and are in the production phase. I recorded (2) milliSiemens/cm conductivity in water next to the berm in the frac tank containment system and next to the Pad berm of the site. There was one frac tank in the containment system. The containment system was not properly secured and had several areas of compromised integrity. I recorded over the limit conductivity in water inside the prodcuction containemnt system. The highest conductivity reading that can be recorded on my meter is (19.99) milliSiemens/cm. The production tanks had noticeable staining. It appears as if the staining occurred as a result of oveflow or misting of production fluid out of the hatches on top of the tanks. I observed a trail of a crystallization/ whitish precipitate on the ground surface of the Pad near the production containment system. |
2355462 | Primary Facility | 2015-03-27 | Routine/Complete Inspection | No Violations Noted | |
2420717 | Primary Facility | 2015-10-29 | Routine/Complete Inspection | No Violations Noted | At time of inspection, arrived on site at 8:45, the cellar had water at the bottom, there was some debris in the cellar, the (9x5) vent pipe was open and venting to a tank, there was 1000psi on the production casing and 1044psi on the production line. I took a walk around the location and everything looked OK. |
2462547 | Primary Facility | 2016-02-29 | Routine/Complete Inspection | No Violations Noted | The Department was on site to inspect the Bush Well Pad, ESX11-115-0118. The wells associated with the pad are as follows:
115-20918 115-20919 115-20910 115-20911 115-20912 115-20913 The site was currently undergoing some modifications to the retention bains and the berm along the side of the pad. The site was stable and well vegetated where the site wasn't under construction and there were no apparent erosional issues. There were no violations. If there are any issues please feel free to contact me. |
2516391 | Primary Facility | 2016-08-26 | Routine/Complete Inspection | No Violations Noted | At time of inspection, arrived on site at 14:40p.m., the cellar had water at the bottom with no bubbling noticed, the (13x9) annulus was open and venting into the atmosphere and no gas was detected, the (9x5) vent pipe was open and venting into a tank. There was 729psi on the production casing and 468psi on the production line. I took a walk around the location and everything looked OK.
I left the site at 15:20p.m. |
2606514 | Primary Facility | 2017-06-20 | Routine/Complete Inspection | No Violations Noted | At time of inspection, arrived on site at 13:40p.m.
The cellar was about a quarter full of water with no bubbling noticed. The (13x9) annulus was open and venting into the atmosphere with no gas detected. The (9x5) annulus vent pipe was open and venting into the production tank. There was 582psi on the production casing and 254psi on the production line. I took a walk around the location and there were no obvious concerns noticed. I left the site at 14:30p.m. |
2656161 | Primary Facility | 2017-11-02 | Routine/Complete Inspection | No Violations Noted | I inspected the Bush well pad on November 1, 2017 for a routine inspection. The access road was solid, stable and well graded. There was active ag ongoing off one side with round bales stored just off the road. The pad surface itself was in good shape as well, with good vegetation on both the topsoil pile and the gentle fill slope. There was some firewood cutting at the edge of the pad, but there was no impact to the pad.
There were no violations noted. |
2712998 | Primary Facility | 2018-03-27 | Routine/Complete Inspection | No Violations Noted | At time of inspection.
The well was in production. There was water 4' below grade in the cellar and there was no bubbling noticed. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted. |
2740421 | Primary Facility | 2018-06-12 | Routine/Complete Inspection | No Violations Noted | I performed a RTNC inspection of the Bush well site. The wells associated with this site are the 115-20918, 115-20919, 115-20920, 115-20921, 115-20922. The wells were properly labeled.
The well site and access road were well graded and stable. There did not appear to be any erosional issues along the access road or on the well pad. The topsoil pile and the fill slopes were well vegetated, with woody plants as well as grasses. There were no areas of instability noted and the slopes appeared stable. There was no puddling onsite. There was some firewood and small scale sawmilling occurring on the pad edge but this was not affecting the pad. There were no erosional issues noted. There were no violations. |
2776045 | Primary Facility | 2018-09-17 | Routine/Complete Inspection | No Violations Noted | I performed an E&S inspection of the Bush wellsite. The wells were all properly labeled. The well pad and access road were solid and stable.
The wellpad had firewood stored on site at the unused corner of the pad. There were crews on site and work was being performed on the compressor house The cut and fill slopes were vegetated and stable. The vegetation was healthy and abundant where the ground was not too rocky. There were no erosional issues noted at the time of inspection. There were no violations noted. |
2815602 | Primary Facility | 2018-12-14 | Routine/Complete Inspection | No Violations Noted | At time of inspection.
The well was in production. There was water 3' below grade in the cellar with no bubbling noticed and there was no gas detected in the remainder of the cellar. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted. |
For data sources see[8]