37-115-20594

Well Details

Well ID: 37-115-20594
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: Springville Township
Operator Name: CABOT OIL & GAS CORP
Well Pad ID: 147743
Farm/Lease Name: AUGUSTINE 3
License Status:
Spud Date:
Permit Date: 2011-06-17
Well Type: GAS
Unconventional Well: Y
Configuration: Vertical Well
Conservation: No
Latitude: 41.688636
Longitude: -75.922086

For data sources see[1][2][3]

Well History

Date Event
2011-06-17 New Permit Application
2011-08-01 Performed Spud Operation
2011-11-01 Drilling Completion
2012-02-06 NEWLY DRILLED
2012-09-23 Drilling Completion
2012-10-30 Performed Stimulation
2014-05-21 DRILLED DEEPER

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2012-10-29 2012-10-29 5,652 105,840

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Sand, White, 40/70 Baker Hughes Proppant Quartz 14808-60-7 1.00 0.04
Alpha 1427 Baker Hughes Biocide Didecyl dimethyl ammonium chloride 7173-51-5 0.10 0.00002000
Quaternary ammonium compounds,
benzyl-C12-16-alkyldimethyl, chlorides
68424-85-1 0.05 0.00001000
Glutaraldehyde 111-30-8 0.30 0.00007000
Ethanol 64-17-5 0.05 0.00001000
Scaletrol 720 Baker Hughes Scale Inhibitor Calcium chloride 10043-52-4 0.05 0.00001000
Ethylene glycol 107-21-1 0.30 0.00008000
Water Operator Carrier Water 7732-18-5 1.00 0.90
Superset-W Baker Hughes Activator Methanol 67-56-1 0.50 0.00085000
Nonyl phenol ethoxylate 9016-45-9 0.50 0.00085000
Super LC, 30/50 Baker Hughes Proppant Quartz 14808-60-7 0.97 0.04
Phenolic resin 9003-35-4 0.05 0.00249000
Methenamine 100-97-0 0.00010000 0.00
FRW-18 Baker Hughes Friction Reducer Distillates, petroleum, hydrotreated light 64742-47-8 0.30 0.00019000

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2012-10-30 0 0 0

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2011 CABOT OIL & GAS CORP 0.00 0 0.00 0 0.00 0
2012 CABOT OIL & GAS CORP 4,177.68 16 0.00 0 0.00 0
2013 CABOT OIL & GAS CORP 21,430.56 365 0.00 0 0.00 0
2014 CABOT OIL & GAS CORP 16,317.71 318 0.00 0 0.00 0
2015 CABOT OIL & GAS CORP 7,671.72 230 0.00 0 0.00 0
2016 CABOT OIL & GAS CORP 9,666.76 359 0.00 0 0.00 0
2017 CABOT OIL & GAS CORP 6,140.13 309 0.00 0 0.00 0
2018 CABOT OIL & GAS CORP 2,302.00 121 0.00 0 0.00 0
2019 CABOT OIL & GAS CORP 4,821.00 220 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2011 CABOT OIL & GAS CORP Drilling Fluid Waste 4,722.57 Bbl REUSE OTHER THAN ROAD SPREADING
2011 CABOT OIL & GAS CORP Drill Cuttings 7.47 Tons LANDFILL 101534
2011 CABOT OIL & GAS CORP Drill Cuttings 194.32 Tons LANDFILL 101247
2011 CABOT OIL & GAS CORP Drill Cuttings 3,320.09 Tons LANDFILL THR029
2011 CABOT OIL & GAS CORP Drill Cuttings 5.69 Tons LANDFILL 100081
2012 CABOT OIL & GAS CORP Produced Fluid 79.60 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CABOT OIL & GAS CORP Basic Sediment 0.74 Bbl LANDFILL THR029
2012 CABOT OIL & GAS CORP Fracing Fluid Waste 7,345.37 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CABOT OIL & GAS CORP Fracturing Fluid Waste 12.16 Tons LANDFILL THR029
2012 CABOT OIL & GAS CORP Drill Cuttings 124.76 Tons LANDFILL 301626
2012 CABOT OIL & GAS CORP Drilling Fluid Waste 717.17 Bbl LANDFILL THR029
2012 CABOT OIL & GAS CORP Fracing Fluid Waste 1,986.67 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NE001
2013 CABOT OIL & GAS CORP Produced Fluid 54.64 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NE002
2013 CABOT OIL & GAS CORP Produced Fluid 188.76 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2014 CABOT OIL & GAS CORP Produced Fluid 174.76 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2015 CABOT OIL & GAS CORP Produced Fluid 17.50 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2016 CABOT OIL & GAS CORP Synthetic Liner Materials 0.64 Tons LANDFILL 101247
2017 CABOT OIL & GAS CORP Waste Water Treatment Sludge 4.78 Tons REUSE (AT WELL PAD)
2017 CABOT OIL & GAS CORP Produced Fluid 5.60 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2018 CABOT OIL & GAS CORP Waste Water Treatment Sludge 0.72 Tons REUSE (AT WELL PAD)
2018 CABOT OIL & GAS CORP Produced Fluid 2.27 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2019 CABOT OIL & GAS CORP Synthetic Liner Materials 0.29 Tons LANDFILL 101247
2019 CABOT OIL & GAS CORP Produced Fluid 202.21 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2019 CABOT OIL & GAS CORP Produced Fluid 0.39 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE004

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1990340 Primary Facility 2011-07-22 Routine/Complete Inspection No Violations Noted
2000375 Primary Facility 2011-08-25 Drilling/Alteration No Violations Noted Patterson 252. Company Man not available. 13 3/8" cemented with 460 sks with 25 bbl returns. Set at 585'. Floats held. Secondary containment in place and in good condition.
2005264 Primary Facility 2011-09-21 Drilling/Alteration No Violations Noted Follow up on status of well. Operator had taken excessive gas kick and have been in process of pluggin off gas so they can kick off and drill out. Drill pipe is free @3940'. Well is currently dead with 17.1 mud weight. Coil tubing unit ran out of diesel and uncoiled. At time of inspection trying to get tubing out of hole. Coil tubing unit on site to displace water in drill pipe with 17.1 mud.
2007054 Primary Facility 2011-08-23 Routine/Complete Inspection Violation(s) Noted
2007193 Primary Facility 2011-09-27 Drilling/Alteration No Violations Noted Patterson 252. Have cement plug set. Top of plug at 3350'. Currently no gas present above plug. Bottom of pipe at 3935'. Have 16.6 wt mud in hole and are slowly reduing mud wt at .10 lb at a time ciculating 5 bottoms up each interval.
2007204 Primary Facility 2011-08-29 Routine/Complete Inspection Violation(s) Noted
2007235 Primary Facility 2011-08-25 Routine/Complete Inspection No Violations Noted
2009267 Primary Facility 2011-10-03 Drilling/Alteration No Violations Noted Patterson 252. Flaring at time of inspection. Currently circulating 4 bottoms up at .10 ppg mud weight intervals. Currently at 13.7 ppg. Goal is to bring mud wt down to water weight equivalent while working gas up out of the hole. Drill pipe bottom is at 3300' (50 ' off bottom). Will continue to circulate for several days.
2012667 Primary Facility 2011-10-19 Drilling/Alteration No Violations Noted DEP on site 11:30. Patterson 252. Currently at 11.8 mud wt. Previously weighted down to water wt.and still had minimal amount of gas. At time of inspection rig broke down. Will be going back in hole to tag TOC. Eventually will be running 7" casing to fracture zone @5600' and produce through 7". DEP off site at 12:25.
2119423 Primary Facility 2012-11-21 Routine/Complete Inspection No Violations Noted
2542988 Primary Facility 2016-12-08 Site Restoration No Violations Noted
2743170 Primary Facility 2018-06-18 Routine/Complete Inspection No Violations Noted This well is in production. Personnel were applying temporary stabilization BMPs to the disturbed areas during the inspection. There were no violations noted. If you have any questions, please contact me.
2757357 Primary Facility 2018-07-11 Drilling/Alteration No Violations Noted At time of inspection arrived on location at 15:30. (4) new 20" conductors, 16" mouse-holes and CellarTech units have been set on pad. Liner and drilling mats have been placed on location in preparation for future drilling activities. (4) new annular vent tanks have been placed at edge of pad with annular vents plumbed from cellars to tanks for all (4) new wells on pad.

- There are also (2) existing wells on pad, the 3H and 4H. Both these wells have been temporarily shut in with night caps installed. Both wells had (2) annular vents, the (13 3/8"x 9 5/8") and (9 5/8"x 5 1/2") vents plumbed to individual vent tanks for each well. Gas checks performed at vent tank openings showed: Tank #1 = 100% LEL, 60% CH4; Tank #2 = 100% LEL, 7% CH4. Well heads were covered with protective steel plates limiting access at time of inspection. No markings were noted on these wells vent tanks to indicate which well was which. Gas checks performed 3' away from vent tanks showed 0% LEL, 0% CH4. Since no health and safety concer

2758427 Primary Facility 2018-07-24 Drilling/Alteration No Violations Noted I arrived at the site at 12:49. The weather conditions are cloudy skies, breezy and humid with rain showers and temperatures in the low to mid 70's as I arrived to the site. The rain had stopped shortly after I arrived. Precision Drilling Rig Super Single # 181 is on the location. The current drilling depth is (666) feet. I met with Will Dean, site company man, consultant of Cabot Oil and Gas and Frank Estes of Cabot Oil and Gas out of the Pittsburgh Office. Mr. Dean provided me with the following details in reference to site activities. "The rig mobilized to the site on July 19th. We are currently drilling the 9H well. The surface casing section of this well will be cemented between (720-800) feet. Thus far, the surface casing on the 11H and 13H wells has been cemented. The next well to be drilled with the surface casing cemented will be the 5H. The 3H and 4H were in production, but are currently shut in. The production fluid storage tanks have been removed from the location. Nabors Rig X 36 will dr
2807103 Primary Facility 2018-10-16 Routine/Complete Inspection No Violations Noted Jon Sassi (EPS) and I arrived on site at 1304 to conduct a FUI inspection on behalf of the Department.

Upon our arrival, we spoke with Brian Kudrick (EHS Consultant - Cabot) who directed us to the location of the release and accompanied us until his colleagues arrived. Roughly 10 minutes after beginning our inspection Steve Watson, Brody Webster, and Steve Catalfamo (all of whom were representing Cabot) arrived on site.

During our discussion with Cabot, they informed us that the liner used for drilling and well stimulation operations is 40 mil thickness layered in a felt-liner-felt arrangement as seen in photo #4. They informed us that Cabot's SOP is to inspect the liner between drilling and fracing and make any repairs as needed. They then remove any contaminants and lay it back down if it is deemed suitable for reuse. According to the aforementioned Cabot representatives we spoke with on site, 2 roll off dumpsters of material have been excavated so far containing 30 yards each.

According to Cabot, the s

2808691 Primary Facility 2018-11-21 Incident- Response to Accident or Event No Violations Noted I arrived at the site at 11:05 in response to a reported spill incident of (10) gallons of diesel fuel. The weather conditions are cloudy skies, breezy and chilly with snow flurries, and temperatures in the low 30's. Steve Watson, Environmental Health and Safety Specialist, and Herb Swiney, completions consultant, both of Cabot Oil and Gas were at the site during the inspection. Keane is the Cabot subcontractor at the site conducting hydraulic fracturing (stimulation) operations for the B Augustine 5H, 9H, 11H and 13H wells. Cabot submitted stimulation notices to the Department on 10/24/18. The comments in the notices indicate that frac operations would begin at 8 AM on 10/25/18. Frac operations are temporarily suspended today, 11/21/18, due to the Thanksgiving holiday according to Mr. Watson. Operations will resume on 11/23/18, Mr. Watson indicated. The 3H and 4H wells are the existing wells on the pad. These wells are currently shut in. The production equipment associated with these wells has been

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2007054 621318 08/23/2011 2011-08-23 691.1 - Clean Streams Law-General. Used only when a specific CLS code cannot be used Administrative 402
2007054 621319 08/23/2011 2011-08-23 SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. Environmental Health & Safety 6018.610
2007204 621333 08/29/2011 2011-08-29 691.1 - Clean Streams Law-General. Used only when a specific CLS code cannot be used Administrative 402
2007204 621334 08/29/2011 2011-08-29 SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. Environmental Health & Safety 6018.610

For data sources see[9]