Well ID: 37-115-20586 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.891836,"lon":-76.004722,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Susquehanna | |
Municipality: Forest Lake Township | |
Operator Name: BKV OPR LLC | |
Well Pad ID: 145325 | |
Farm/Lease Name: BAKER WEST 1H | |
License Status: | |
Spud Date: | |
Permit Date: 2011-05-16 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.891836 | |
Longitude: -76.004722 |
Date | Event |
---|---|
2011-05-16 | New Permit Application |
2011-07-15 | Performed Spud Operation |
2011-11-13 | Drilling Completion |
2012-08-17 | DEVIATED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2012-05-25 | 2012-05-25 | 6,361 | 6,290,634 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Water | Operator | Carrier | Water | 7732-18-5 | 100.00 | 87.39 | |
Ingredients shown above are subject to 29 CFR 1910.1200(i) and appear on Material Safety Data Sheets (MSDS). Ingredients shown below are Non-MSDS. |
Baker Hughes | Surfactant | ||||||
Alpha 1427 | Baker Hughes | Biocide | Quaternary ammonium compounds, benzyl-C12-16-alkyldimethyl, chlorides |
68424-85-1 | 5.00 | 0.00112000 | ||
Glutaraldehyde | 111-30-8 | 30.00 | 0.00671000 | |||||
Didecyl dimethyl ammonium chloride | 7173-51-5 | 10.00 | 0.00224000 | |||||
Ethanol | 64-17-5 | 5.00 | 0.00112000 | |||||
InFlo 250W | Baker Hughes | Surfactant | Methanol | 67-56-1 | 30.00 | 0.00018000 | ||
2-Butoxyethanol | 111-76-2 | 5.00 | 0.00003000 | |||||
Surfactants | 80.00 | 0.00049000 | ||||||
Sand, White, 30/50 | Baker Hughes | Proppant | Quartz | 14808-60-7 | 100.00 | 6.33 | ||
Sand, White, 40/70 | Baker Hughes | Proppant | Quartz | 14808-60-7 | 100.00 | 4.59 | ||
Ferrotrol 300L | Baker Hughes | Iron Control | Citric acid | 77-92-9 | 60.00 | 0.00139000 | ||
Sand, White, 100 | Baker Hughes | Proppant | Quartz | 14808-60-7 | 100.00 | 0.83 | ||
Scaletrol 720 | Baker Hughes | Scale Inhibitor | Ethylene glycol | 107-21-1 | 30.00 | 0.00460000 | ||
Calcium chloride | 10043-52-4 | 5.00 | 0.00077000 | |||||
Ingredients shown above are subject to 29 CFR 1910.1200(i) and appear on Material Safety Data Sheets (MSDS). Ingredients shown below are Non-MSDS. |
Poly (acrylamide-co-acrylic acid) | 0.02 | ||||||
Polyacrylate | 0.00306832 | |||||||
Ethoxylated Alcohol | 0.00138241 | |||||||
Thiourea polymer | 68527-49-1 | |||||||
Water | 7732-18-5 | 0.05 | ||||||
Potassium chloride | 7447-40-7 | 0.00000767 | ||||||
Formalin | 50-00-0 | |||||||
Salt | 0.00345602 | |||||||
Sodium chloride | 7647-14-5 | 0.00000460 | ||||||
Hydrochloric acid | 7647-01-0 | |||||||
Sorbitan Monooleate | 0.00345602 | |||||||
Hydrochloric Acid 5.1-7.5 | Baker Hughes | Acidizing | Water | 7732-18-5 | 92.50 | 0.65 | ||
Hydrochloric acid | 7647-01-0 | 7.50 | 0.05 | |||||
FRW-18 | Baker Hughes | Friction Reducer | Distillates, petroleum, hydrotreated light | 64742-47-8 | 30.00 | 0.02 | ||
CI-14 | Baker Hughes | Corrosion Inhibitor | Propargyl alcohol | 107-19-7 | 5.00 | 0.00003000 | ||
Ethoxylated C14-15 alcohols | 68951-67-7 | 30.00 | 0.00016000 | |||||
Alkenes, C>10 .alpha.- | 64743-02-8 | 5.00 | 0.00003000 | |||||
Fatty acids, tall-oil | 61790-12-3 | 10.00 | 0.00005000 | |||||
Methanol | 67-56-1 | 100.00 | 0.00053000 | |||||
mesh | Hughes | Proppant |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2011 | CARRIZO (MARCELLUS) LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | CARRIZO (MARCELLUS) LLC | 1,089,542.00 | 202 | 0.00 | 0 | 0.00 | 0 |
2013 | CARRIZO (MARCELLUS) LLC | 1,015,737.00 | 313 | 0.00 | 0 | 0.00 | 0 |
2014 | CARRIZO (MARCELLUS) LLC | 46,799.25 | 28 | 0.00 | 0 | 0.00 | 0 |
2015 | CARRIZO (MARCELLUS) LLC | 1,771,425.03 | 283 | 0.00 | 0 | 0.00 | 0 |
2016 | CARRIZO (MARCELLUS) LLC | 1,438,720.72 | 352 | 0.00 | 0 | 0.00 | 0 |
2017 | CARRIZO (MARCELLUS) LLC | 633,052.03 | 359 | 0.00 | 0 | 0.00 | 0 |
2018 | BKV OPR LLC | 431,000.03 | 364 | 0.00 | 0 | 0.00 | 0 |
2019 | BKV OPR LLC | 308,831.61 | 362 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2011 | CARRIZO (MARCELLUS) LLC | Drill Cuttings | 155.00 Tons | LANDFILL | THR029 |
2012 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 21,976.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 453.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE003 |
2013 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 1,139.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 70.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR119 |
2014 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 1,494.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
2014 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 1,495.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2015 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 206.68 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
2015 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 873.90 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE003 |
2015 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 44.74 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2015 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 2,241.17 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | CARRIZO (MARCELLUS) LLC | Other Oil & Gas Wastes | 18.25 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
2016 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 105.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2016 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 158.62 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
2016 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 484.44 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE003 |
2016 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 354.06 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE003 |
2016 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 84.62 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
2016 | CARRIZO (MARCELLUS) LLC | Basic Sediment | 333.33 Bbl | LANDFILL | THR029 |
2016 | CARRIZO (MARCELLUS) LLC | Other Oil & Gas Wastes | 18.25 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE003 |
2016 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 487.81 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2016 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 105.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2017 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 159.51 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2017 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 472.49 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2017 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 64.60 Bbl | REUSE (AT WELL PAD) | |
2017 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 335.33 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE003 |
2017 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 30.99 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2018 | BKV OPR LLC | Produced Fluid | 35.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE003 |
2018 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 475.38 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2018 | BKV OPR LLC | Produced Fluid | 70.00 Bbl | REUSE (AT WELL PAD) | |
2019 | BKV OPR LLC | Produced Fluid | 35.32 Bbl | REUSE (AT WELL PAD) | |
2019 | BKV OPR LLC | Produced Fluid | 175.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE003 |
2019 | BKV OPR LLC | Produced Fluid | 451.19 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2007312 | Primary Facility | 2011-09-29 | Routine/Complete Inspection | No Violations Noted | |
2014445 | Primary Facility | 2011-10-25 | Drilling/Alteration | No Violations Noted | DEP on site at 11:50. Nabors Rig MO5. Rigging up. Site lined with plastic and wood/steel matting. Should start drilling later this evening. no violation observed. |
2077613 | Primary Facility | 2012-06-13 | Routine/Complete Inspection | No Violations Noted | During the investigation, I used an Extech, ExStik (2) pH, Conductivity, Salinty and TDS meter to field screen ponded water inside the containment area where the on-site mobile pretreatment system to filter frac flowback fluid is located. I also screened an area outside the containment area in the NW corner of the Well Pad and the edge of the Well Pad off containment behind the storage tanks. Conductivity, Salinity and TDS readings indicated over the limit, with the limit on the meter being 19.99 milliSiemens/cm. I performed sampling analysis of (2) areas of ponded water behind the storage tanks in the west section of the Well Pad, based on the readings on my meter. I departed from the site at 14:00. |
2081472 | Primary Facility | 2012-06-18 | Incident- Response to Accident or Event | Violation(s) Noted | Arrived at the site at 10:30 AM in response to a production fluid release that occurred at the site on 6-15-12. Carrizo reported the release to the Department at 15:50 on 6-15-12. According to Carizzo, the release occurred sometime between 10:30 and 10:45 on 6-15-12. The release occurred as a result of a pipe fitting being removed from its position on a pressurized line. The line then remained open and exposed to the atmosphere. The estimated volume of production fluid released was determined to be (2) to (3) barrels. The production fluid release impacted the surface of the ground on the Well Pad in a relatively close proximity to the production equipment at the site. The fluid traveled in a vertical direction out of the opened pressurized line and then contacted the surface of the ground on the Well Pad. It then changed direction and flowed off the Well Pad a maximum distance of (10) feet down a slope into a vegetated area next to the water transfer line and gas pipeline right of way. |
2089153 | Primary Facility | 2012-08-06 | Administrative/File Review | Violation(s) Noted | The Department is issuing a Notice of Violation based on the sample results of ponded water on the surface of the ground on the Well Pad and an incident report submitted by Carrizo to the Department via e-mail on 7/26/12. The sample was collected during the 6-13-12 inspection of the Baker West Well Pad. The sample was collected as a result of an over the limit conductivity reading in the ponded water. Please refer to the Baker West 1H, 6-13-12 inspection report for details. DEP Labs submitted the final results on 8/6/12 of the samples collected by the Department on 6/13/12. The results indicated elevated concentrations of the following parameters. |
2356101 | Primary Facility | 2015-03-30 | Routine/Complete Inspection | No Violations Noted | |
2419284 | Primary Facility | 2015-10-27 | Routine/Complete Inspection | No Violations Noted | At time of inspection, arrived on site at 11:15, the cellar was empty, the (9x5½) vent pipe was open and venting to a tank, there was 1331psi on the production casing and 873psi on the production line. I took a walk around the location and everything looked OK. |
2451816 | Primary Facility | 2016-01-21 | Routine/Complete Inspection | No Violations Noted | The Department was on site to inspect the Baker West well pad (ESX10-115-0081 (01)). The wells associated with the pad are as follows:
115-20584 115-20585 115-20586 The site was stable and well vegetated with no apparent erosional issues. There were no violations. If there are any issues please feel free to contact me. |
2513784 | Primary Facility | 2016-08-25 | Routine/Complete Inspection | No Violations Noted | At time of inspection, arrived on site at 12:30p.m., the cellar had water at the bottom with no bubbling noticed; the (9x5) vent pipe was open and venting into a tank. There was 843psi on the production casing and about 599psi on the production line. I took a walk around the location and everything looked OK.
I left the site at 13:05p.m. |
2544474 | Primary Facility | 2016-10-25 | Site Restoration | No Violations Noted | The Department was on site to inspect the Baker well pad (ESX10-115-0029). The wells associated with the pad are as follows:
115-20471 115-20470 115-20469 115-20468 115-20467 115-20466 115-20465 The well pad was vegetated in excess of the 70% perennial vegetative standard, the grading was up to par and the temporary BMPs had been removed from the site. The site was stable and well vegetated with no apparent erosional issues. I recommend APPROVAL of this Notice Of Termination. There were no violations. If there are any issues please feel free to contact me. |
2608695 | Primary Facility | 2017-06-27 | Routine/Complete Inspection | No Violations Noted | At time of inspection, arrived on site at 13:20p.m.
The cellar was empty. The (9x5) annulus vent pipe was open and venting into the production tank. There was 508psi on the production casing and 432psi on the production line. I noticed staining on the ground near the 3H well, I showed Matt Mercaldo of J P Reilly (contractor for Carrizo) where the stain was and he said he would get it cleaned up. I contacted Frank Hoehle (DEP water quality specialist) to let him know of the staining and he said he would do a follow-up inspection. I took a walk around the location and there were no obvious concerns noticed. I left the site at 14:00p.m. |
2622508 | Primary Facility | 2017-08-04 | Routine/Complete Inspection | No Violations Noted | I inspected the Baker West well pad on July 20, 2017. The access road leading in was in good condition, with no debris leaving the site onto the macadam road (Turnpike Road). The well pad itself was solid and stable as well, with no excessive mud or ponding. There was some ponding but it just rained heavily the previous day. The cut slope had vegetation where it was not rock. The fill slopes were stable and solid despite recent heavy rains. All vegetation on site was thick, lush and perennial. There were no erosional issues observed during the inspection.
There were no violations noted. |
2715658 | Primary Facility | 2018-04-04 | Routine/Complete Inspection | No Violations Noted | At time of inspection.
The well was in production. There was cement between the (20x13) and (13x9) annuli and there was no gas detected. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted. |
2816509 | Primary Facility | 2018-12-17 | Routine/Complete Inspection | No Violations Noted | At time of inspection.
The well was in production. There was water 4.5' below grade in the cellar with no bubbling noticed and there was no gas detected in the remainder of the cellar with a MSA Altair 5X multi gas detector that was calibrated on 12/3/18. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted. |
2851764 | Primary Facility | 2019-03-11 | Routine/Complete Inspection | No Violations Noted | I inspected the Baker West well site on March 11, 2019. The weather was sunny and about 33 degrees F. The site had no activity at the time of inspection. There was a considerable amount of snow and ice still on site.
The access road and well pad surface were fairly icy but stable and did not have any mud or erosional issues. The wells on the pad surface were all enclosed in carports, with clean gravel surrounding them and legible signs on each. The infiltration basins and fill slopes were stable, as were the cut slope areas. The cut slope had a rocky appearance without much vegetation due to the nature of the ground, and no erosion was noted. There was a logging operation noted but it was off the well site LOD. It was not affecting the wellsite. The containment structure surrounding the production tanks and equipment had sufficient freeboard. There were no areas of instability noted onsite and no sheen was noted on any water surfaces during the inspection. There were no violations noted. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
2081472 | 643402 | 06/18/2012 | 2012-06-18 | 402CSL - Failure to adopt pollution prevention measures required or prescribed by DEP by handling materials that create a danger of pollution. | Environmental Health & Safety | |
2081472 | 643403 | 06/18/2012 | 2012-06-18 | 91.33A - Failure to notify DEP of pollution incident. No phone call made forthwith | Administrative | Failure to immediately report an incident that causes or threatens pollution |
2081472 | 643404 | 06/18/2012 | 2012-06-18 | 78.57 - Failure to post pit approval number | Administrative | Failure to collect the brine and other fluids produced during the operation and service of the well in a tank, pit or a series of pits or tanks, or other device approved by DEP |
2081472 | 643405 | 06/18/2012 | 2012-06-18 | SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. | Environmental Health & Safety | |
2081472 | 643406 | 06/18/2012 | 2012-06-18 | 78.66BRINE - Failure to report a reportable release of brine to DEP within 2 hours. | Administrative | |
2089153 | 645762 | 08/06/2012 | 2012-08-06 | 402CSL - Failure to adopt pollution prevention measures required or prescribed by DEP by handling materials that create a danger of pollution. | Environmental Health & Safety | |
2089153 | 645763 | 08/06/2012 | 2012-08-06 | 78.56(1) - Pit and tanks not constructed with sufficient capacity to contain pollutional substances. | Administrative | |
2089153 | 645764 | 08/06/2012 | 2012-08-06 | 91.33A - Failure to notify DEP of pollution incident. No phone call made forthwith | Administrative | |
2089153 | 645765 | 08/06/2012 | 2012-08-06 | SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. | Environmental Health & Safety |
Violation ID | Penalty ID | Penalty Code | Penalty Status | Penalty Date | Enforcement Date | Penalty Amount | Amount Collected |
---|---|---|---|---|---|---|---|
643402 | 285776 | NOV - Notice of Violation | Administrative Close Out | 2012-07-09 | |||
643403 | 285776 | NOV - Notice of Violation | Administrative Close Out | 2012-07-09 | |||
643404 | 285776 | NOV - Notice of Violation | Administrative Close Out | 2012-07-09 | |||
643405 | 285776 | NOV - Notice of Violation | Administrative Close Out | 2012-07-09 | |||
643406 | 285776 | NOV - Notice of Violation | Administrative Close Out | 2012-07-09 | |||
645762 | 287538 | NOV - Notice of Violation | Administrative Close Out | 2012-08-20 | |||
645763 | 287538 | NOV - Notice of Violation | Administrative Close Out | 2012-08-20 | |||
645764 | 287538 | NOV - Notice of Violation | Administrative Close Out | 2012-08-20 | |||
645765 | 287538 | NOV - Notice of Violation | Administrative Close Out | 2012-08-20 |