If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-115-20539 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.895967,"lon":-75.989419,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Susquehanna | |
Municipality: Forest Lake Township | |
Operator Name: BKV OPR LLC | |
Well Pad ID: 145333 | |
Farm/Lease Name: BAKER NORTH 4H | |
License Status: | |
Spud Date: | |
Permit Date: 2011-04-29 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.895967 | |
Longitude: -75.989419 |
Date | Event |
---|---|
2011-04-29 | New Permit Application |
2011-05-23 | Performed Spud Operation |
2011-10-16 | Drilling Completion |
2012-08-17 | DEVIATED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2012-01-06 | 2012-01-06 | 6,194 | 4,798,290 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Water | Operator | Carrier | Water | 7732-18-5 | 100.00 | 84.08 | |
Sand, White, 40/70 | Baker Hughes | Proppant | Quartz | 14808-60-7 | 100.00 | 7.37 | ||
GW-3LDF | Baker Hughes | Gelling Agent | Petroleum Distillate Blend | 70.00 | 0.00037000 | |||
Guar gum | 9000-30-0 | 40.00 | 0.00021000 | |||||
Sand, White, 100 mesh | Baker Hughes | Proppant | Quartz | 14808-60-7 | 100.00 | 1.56 | ||
CI-14 | Baker Hughes | Corrosion Inhibitor | Alkenes, C>10 .alpha.- | 64743-02-8 | 5.00 | 0.00004000 | ||
Propargyl alcohol | 107-19-7 | 5.00 | 0.00004000 | |||||
Methanol | 67-56-1 | 100.00 | 0.00088000 | |||||
Ethoxylated C14-15 alcohols | 68951-67-7 | 30.00 | 0.00027000 | |||||
Fatty acids, tall-oil | 61790-12-3 | 10.00 | 0.00009000 | |||||
Additional Ingredients | Surfactant | Hydrochloric acid | 7647-01-0 | |||||
2-Propenoic, Polymer with Sodium Phosphinate, Sodium Salt | 71050-62-9 | |||||||
2-Butoxyethanol | 111-76-2 | |||||||
Formalin | 50-00-0 | |||||||
Water | 7732-18-5 | |||||||
Poly(oxy-1,2-ethanediyl), alpha-tridecyl-omega-hydroxy- | 24938-91-8 | |||||||
Quaternary ammonium compounds, bis(hydrogenated tallow alkyl)dimethyl, salts with bentonite |
68953-58-2 | |||||||
Quartz | 14808-60-7 | |||||||
Calcium chloride | 10043-52-4 | |||||||
InFlo 250W | Baker Hughes | Surfactant | Methanol | 67-56-1 | 30.00 | 0.00030000 | ||
2-Butoxyethanol | 111-76-2 | 20.00 | 0.00020000 | |||||
Surfactants | 80.00 | 0.00081000 | ||||||
FRW-18 | Baker Hughes | Friction Reducer | Distillates, petroleum, hydrotreated light | 64742-47-8 | 30.00 | 0.05 | ||
GBW-15L | Baker Hughes | Breaker | Enzyme solution | 100.00 | 0.00002000 | |||
Sand, White, 30/50 | Baker Hughes | Proppant | Quartz | 14808-60-7 | 100.00 | 6.23 | ||
Ferrotrol 300L | Baker Hughes | Iron Control | Citric acid | 77-92-9 | 60.00 | 0.00231000 | ||
Hydrochloric Acid 5.1-7.5 | Baker Hughes | Acidizing | Hydrochloric acid | 7647-01-0 | 7.50 | 0.04 | ||
Water | 7732-18-5 | 92.50 | 0.59 | |||||
Additional Ingredients | Baker Hughes | Surfactant | Thiourea polymer | 68527-49-1 | ||||
Alpha 1427 | Baker Hughes | Biocide | Quaternary ammonium compounds, benzyl-C12-16-alkyldimethyl, chlorides |
68424-85-1 | 7.00 | 0.00158000 | ||
Ethanol | 64-17-5 | 5.00 | 0.00113000 | |||||
Didecyl dimethyl ammonium chloride | 7173-51-5 | 10.00 | 0.00226000 | |||||
Glutaraldehyde | 111-30-8 | 30.00 | 0.00678000 | |||||
Water | 7732-18-5 | 60.00 | 0.01 | |||||
Scaletrol 720 | Baker Hughes | Scale Inhibitor | Ethylene glycol | 107-21-1 | 45.00 | 0.00665000 | ||
Diethylene glycol | 111-46-6 | 5.00 | 0.00074000 | |||||
Enzyme G-NE | Baker Hughes | Breaker | Hemicellulase Enzyme Concentrate | 9025-56-3 | 5.00 | 0.00 | ||
Water | 7732-18-5 | 95.00 | 0.00007000 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2011 | CARRIZO (MARCELLUS) LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | CARRIZO (MARCELLUS) LLC | 786,693.00 | 278 | 0.00 | 0 | 0.00 | 0 |
2013 | CARRIZO (MARCELLUS) LLC | 322,970.00 | 228 | 0.00 | 0 | 0.00 | 0 |
2014 | CARRIZO (MARCELLUS) LLC | 7,708.07 | 9 | 0.00 | 0 | 0.00 | 0 |
2015 | CARRIZO (MARCELLUS) LLC | 197,692.00 | 99 | 0.00 | 0 | 0.00 | 0 |
2016 | CARRIZO (MARCELLUS) LLC | 128,912.45 | 146 | 0.00 | 0 | 0.00 | 0 |
2017 | CARRIZO (MARCELLUS) LLC | 151,525.21 | 287 | 0.00 | 0 | 0.00 | 0 |
2018 | BKV OPR LLC | 117,777.71 | 363 | 0.00 | 0 | 0.00 | 0 |
2019 | BKV OPR LLC | 84,347.38 | 361 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2011 | CARRIZO (MARCELLUS) LLC | Drill Cuttings | 270.00 Tons | LANDFILL | NY STATE #32S11 |
2011 | CARRIZO (MARCELLUS) LLC | Drill Cuttings | 223.94 Tons | LANDFILL | THR029 |
2012 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 21,542.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 223.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 205.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE003 |
2014 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 21.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR119 |
2014 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 86.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 930.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
2014 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 930.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2015 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 90.80 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2015 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 46.03 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
2015 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 4.60 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
2015 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 12.19 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE003 |
2015 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 69.28 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | CARRIZO (MARCELLUS) LLC | Other Oil & Gas Wastes | 23.87 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
2016 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 16.03 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2016 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 23.43 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2016 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 33.50 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE003 |
2016 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 29.68 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
2016 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 63.14 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE003 |
2016 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 18.59 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
2016 | CARRIZO (MARCELLUS) LLC | Other Oil & Gas Wastes | 23.87 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE003 |
2016 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 7.79 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2017 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 194.52 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2017 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 206.30 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE003 |
2017 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 40.14 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2017 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 13.53 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2017 | CARRIZO (MARCELLUS) LLC | Other Oil & Gas Wastes | 2.98 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE003 |
2018 | BKV OPR LLC | Produced Fluid | 26.25 Bbl | REUSE (AT WELL PAD) | |
2018 | BKV OPR LLC | Synthetic Liner Materials | 1.13 Tons | LANDFILL | 101247 |
2018 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 387.91 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2019 | BKV OPR LLC | Produced Fluid | 26.25 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR119 |
2019 | BKV OPR LLC | Synthetic Liner Materials | 1.33 Tons | RESIDUAL WASTE TRANSFER FACILITY | 101714 |
2019 | BKV OPR LLC | Produced Fluid | 143.75 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2007336 | Primary Facility | 2011-09-29 | Routine/Complete Inspection | No Violations Noted | |
2011526 | Primary Facility | 2011-10-14 | Drilling/Alteration | Violation(s) Noted | DEP on site 9:00. Nabors Rig MO5. Preparing to run production string. Drilling on SOBM. Drillers log on site and up to date. Walked site with Co. Man. Cuttings off containment on back edge of pad alongside solids tanks. Violations cited. Operator shall clean up and report to DEP when complete. |
2052000 | Primary Facility | 2012-03-20 | Routine/Complete Inspection | No Violations Noted | 4-h is shut in awaiting fishing job on drillout motor |
2077186 | Primary Facility | 2012-06-08 | Routine/Complete Inspection | No Violations Noted | Well is online. Gauge on production shows 1200 lbs. Well tag is on well head. There is miscellaneous trash and debris in the cellar. Operator is to remove standing liquid and trash and debris from the cellar. Please notify DEP upon completion. |
2354595 | Primary Facility | 2015-03-24 | Routine/Complete Inspection | No Violations Noted | |
2424239 | Primary Facility | 2015-11-12 | Routine/Complete Inspection | No Violations Noted | At time of inspection, arrived on site at 12:45 p.m., the cellar was empty, the (9x5) vent pipe was open and venting to a tank, there was 886psi on the production casing and 69psi on the production line. I took a walk around the location and everything looked OK. |
2451846 | Primary Facility | 2016-01-21 | Routine/Complete Inspection | No Violations Noted | The Department was on site to inspect the Baker North well pad (ESX10-115-0080). The wells associated with the pad are as follows:
115-20536 115-20538 115-20539 115-20540 There was active forestry going on near the site, however the site was stable and well vegetated with no apparent erosional issues. There were no violations. If there are any issues please feel free to contact me. |
2509590 | Primary Facility | 2016-07-28 | Routine/Complete Inspection | No Violations Noted | The Department was on site to inspect the Baker North well pad (ESX10-115-0080). The wells associated with the pad are as follows:
115-20536 115-20538 115-20539 115-20540 The site was stable and well vegetated with no apparent erosional issues. There were no violations. If there are any issues please feel free to contact me. |
2517577 | Primary Facility | 2016-09-08 | Routine/Complete Inspection | No Violations Noted | At time of inspection, arrived on site at 12:40p.m., the cellar had water at the bottom with no bubbling was noticed; the (9x5) vent pipe was open and venting into a tank. There was 746psi on the production casing and 737psi on the production line. I took a walk around the location and noticed what appeared to grease in a water puddle. I contacted Jesse Bonnice of Carrizo to suggest it be cleaned up.
I left the site at 13:15p.m. |
2528715 | Primary Facility | 2016-10-03 | Site Restoration | No Violations Noted | The Department was on site to conduct a Notice of Termination (NOT) for the Baker North well pad (ESX10-115-0080). The wells associated with the pad are as follows:
115-20536 115-20538 115-20539 115-20540 The site was stable and the vegetation was primarily perennial grasses. The vegetation met or exceeded the 70 percent vegetative standard. There were no stability problems to report, and the site was well constructed. There were a few third party trails intercepting the well site, however there were no erosional issues associated with these trails. I recommend APPROVAL of this Notice of Termination for the Baker North Well Pad. There were no violations. If there are any issues please feel free to contact me. |
2606532 | Primary Facility | 2017-06-21 | Routine/Complete Inspection | No Violations Noted | At time of inspection, arrived on site at 9:55a.m.
The cellar was about half full of water with no bubbling noticed. The (9x5) annulus vent pipe was open and venting into a small plastic tank. There was 522psi on the production casing and 393psi on the production line. I took a walk around the location and there were no obvious concerns noticed. I left the site at 10:35a.m. |
2622523 | Primary Facility | 2017-08-04 | Routine/Complete Inspection | No Violations Noted | I inspected the Baker North Well site on July 20, 2017. The site was stable at the time of inspection. The access road leading in had no washing or erosional issues and the pad surface was solid with no excessive ponding or mud issues. The vegetation was well established and healthy looking.
There were no violations noted. |
2715668 | Primary Facility | 2018-04-04 | Routine/Complete Inspection | No Violations Noted | At time of inspection.
The well was in production. There was cement between the (20x13) and (13x9) annuli and there was no gas detected. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted. |
2817684 | Primary Facility | 2018-12-19 | Routine/Complete Inspection | No Violations Noted | At time of inspection.
The well was in production. There was water 5' below grade in the cellar with no bubbling noticed and there was no gas detected in the remainder of the cellar with a MSA Altair 5X multi gas detector that was calibrated on 12/3/18. The production tanks for this site are located on the Baker pad. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
2011526 | 622415 | 10/14/2011 | 2011-10-14 | 78.56(1) - Pit and tanks not constructed with sufficient capacity to contain pollutional substances. | Administrative | Cuttings off containment on back edge of pad alongside solids tanks. |
For data sources see[8]