37-115-20207

Well Details

Well ID: 37-115-20207
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: Dimock Township
Operator Name: CABOT OIL & GAS CORP
Well Pad ID: 148552
Farm/Lease Name: HOOVER 1V
License Status:
Spud Date:
Permit Date: 2009-08-29
Well Type: GAS
Unconventional Well: Y
Configuration: Vertical Well
Conservation: No
Latitude: 41.725375
Longitude: -75.909356

For data sources see[1][2][3]

Well History

Date Event
2009-08-29 New Permit Application
2009-09-19 Performed Spud Operation
2009-10-12 Drilling Completion
2010-01-27 Perforation
2010-03-14 Performed Stimulation
2010-10-01 NEWLY DRILLED

For data sources see[4]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2010-03-14 0 0 0

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2009 CABOT OIL & GAS CORP 0.00 0 0.00 0 0.00 0
2010 CABOT OIL & GAS CORP 107,748.50 226 0.00 0 0.00 0
2011 CABOT OIL & GAS CORP 83,825.00 365 0.00 0 0.00 0
2012 CABOT OIL & GAS CORP 60,873.42 356 0.00 0 0.00 0
2013 CABOT OIL & GAS CORP 39,467.65 361 0.00 0 0.00 0
2014 CABOT OIL & GAS CORP 44,968.94 257 0.00 0 0.00 0
2015 CABOT OIL & GAS CORP 26,301.59 284 0.00 0 0.00 0
2016 CABOT OIL & GAS CORP 40,215.27 354 0.00 0 0.00 0
2017 CABOT OIL & GAS CORP 28,709.47 365 0.00 0 0.00 0
2018 CABOT OIL & GAS CORP 26,378.00 365 0.00 0 0.00 0
2019 CABOT OIL & GAS CORP 22,265.00 359 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2010 CABOT OIL & GAS CORP Drilling Fluid Waste 171.40 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2010 CABOT OIL & GAS CORP Produced Fluid 120.40 Bbl REUSE OTHER THAN ROAD SPREADING
2010 CABOT OIL & GAS CORP Drill Cuttings 14.70 Tons LANDFILL NY # 50S08
2010 CABOT OIL & GAS CORP Basic Sediment 2.22 Bbl LANDFILL 101534
2010 CABOT OIL & GAS CORP Drilling Fluid Waste 103.20 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0101508
2010 CABOT OIL & GAS CORP Drilling Fluid Waste 137.50 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PAD085690592
2010 CABOT OIL & GAS CORP Drill Cuttings 51.90 Tons CENTRALIZED TREATMENT PLANT FOR RECYCLE 101247
2010 CABOT OIL & GAS CORP Drilling Fluid Waste 935.00 Bbl PUBLIC SEWAGE TREATMENT PLANT PA0026034
2010 CABOT OIL & GAS CORP Drill Cuttings 84.40 Tons CENTRALIZED TREATMENT PLANT FOR RECYCLE 8-4630-00010/00
2010 CABOT OIL & GAS CORP Drill Cuttings 84.40 Tons LANDFILL NY # 02S17
2010 CABOT OIL & GAS CORP Drilling Fluid Waste 444.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0008451
2010 CABOT OIL & GAS CORP Drill Cuttings 1.10 Tons LANDFILL 100955
2011 CABOT OIL & GAS CORP Basic Sediment 0.33 Bbl LANDFILL 101534
2011 CABOT OIL & GAS CORP Produced Fluid 76.62 Bbl REUSE OTHER THAN ROAD SPREADING
2013 CABOT OIL & GAS CORP Produced Fluid 44.74 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NE002
2013 CABOT OIL & GAS CORP Produced Fluid 154.64 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2014 CABOT OIL & GAS CORP Produced Fluid 147.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2015 CABOT OIL & GAS CORP Produced Fluid 24.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2016 CABOT OIL & GAS CORP Produced Fluid 3.18 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2016 CABOT OIL & GAS CORP Produced Fluid 7.22 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2017 CABOT OIL & GAS CORP Produced Fluid 38.26 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2018 CABOT OIL & GAS CORP Produced Fluid 52.32 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2019 CABOT OIL & GAS CORP Produced Fluid 44.73 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1890368 Primary Facility 2010-05-24 Routine/Complete Inspection No Violations Noted
1967285 Primary Facility 2011-04-13 Site Restoration No Violations Noted
2138054 Primary Facility 2013-02-05 Follow-up Inspection No Violations Noted Violations associated with this inspection can be referred to in the Hoover 2H 2-5-13 inspection report. Permit number is 115-20177.
2138634 Primary Facility 2013-02-07 Follow-up Inspection No Violations Noted Violations associated with this inspection can be referred to in the Hoover 2H 2-7-13 inspection report. E-facts inspection identification number is 2138579.
2140755 Primary Facility 2013-02-06 Follow-up Inspection No Violations Noted Outstanding violations assocaited with this inspection can be referred to in the Hoover 2H 2-6-13 inspection report. Hoover 2H permit number is 115-20177.
2397717 Primary Facility 2015-08-12 Routine/Complete Inspection No Violations Noted
2439611 Primary Facility 2016-01-07 Site Restoration No Violations Noted Inspection conducted of the COG Hoover D P1 Well Pad covered under E&S permit # 58-09-802b20. Inspection conducted on 1/7/16. The inspection was conducted to confirm COG’s assessment that the site meets the minimum requirements as defined in Chapter 102.22(C) for permanent stabilization which would thus fulfill the physical requirements necessary for the permits termination. The Department’s determination is that the entire site is in fact permanently stabilized and meets the criteria necessary for the permit’s termination. I recommend this notice of termination be approved.
2490191 Primary Facility 2016-06-03 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 9:00 a.m., the cellar was empty with cement between the (20x9) annulus with no gas detected, the (9x4) vent pipe was open and venting to a tank, there was 495 psi on the production casing. I took a walk around the location and everything looked OK.

I left the site at 9:45 a.m.

For data sources see[8]

References