37-115-20186

Well Details

Well ID: 37-115-20186
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: Rush Township
Operator Name: CHESAPEAKE APPALACHIA LLC
Well Pad ID: 148566
Farm/Lease Name: HUNSINGER 2H
License Status:
Spud Date:
Permit Date: 2009-06-25
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.742144
Longitude: -76.103072

For data sources see[1][2][3]

Well History

Date Event
2009-06-25 New Permit Application
2009-10-30 Performed Spud Operation
2009-11-25 Drilling Completion
2010-03-10 Perforation
2010-03-11 Performed Stimulation
2011-04-08 DEVIATED

For data sources see[4]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2010-03-11 0 0 0

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2009 CHESAPEAKE APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2010 CHESAPEAKE APPALACHIA LLC 1,543,075.50 208 0.00 0 0.00 0
2011 CHESAPEAKE APPALACHIA LLC 961,615.00 197 0.00 0 0.00 0
2012 CHESAPEAKE APPALACHIA LLC 794,916.00 260 0.00 0 0.00 0
2013 CHESAPEAKE APPALACHIA LLC 985,136.00 365 0.00 0 0.00 0
2014 CHESAPEAKE APPALACHIA LLC 764,677.00 361 0.00 0 0.00 0
2015 CHESAPEAKE APPALACHIA LLC 328,874.00 295 0.00 0 0.00 0
2016 CHESAPEAKE APPALACHIA LLC 559,611.00 360 0.00 0 0.00 0
2017 CHESAPEAKE APPALACHIA LLC 427,402.00 353 0.00 0 0.00 0
2018 CHESAPEAKE APPALACHIA LLC 334,732.00 353 0.00 0 0.00 0
2019 CHESAPEAKE APPALACHIA LLC 435,446.00 359 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2010 CHESAPEAKE APPALACHIA LLC Fracing Fluid Waste 2,176.00 Bbl REUSE OTHER THAN ROAD SPREADING
2011 CHESAPEAKE APPALACHIA LLC Fracing Fluid Waste 972.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CHESAPEAKE APPALACHIA LLC Produced Fluid 4,387.89 Bbl REUSE OTHER THAN ROAD SPREADING
2013 CHESAPEAKE APPALACHIA LLC Produced Fluid 722.08 Bbl REUSE OTHER THAN ROAD SPREADING
2014 CHESAPEAKE APPALACHIA LLC Produced Fluid 455.34 Bbl REUSE OTHER THAN ROAD SPREADING
2015 CHESAPEAKE APPALACHIA LLC Produced Fluid 83.34 Bbl REUSE OTHER THAN ROAD SPREADING
2016 CHESAPEAKE APPALACHIA LLC Produced Fluid 72.67 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2016 CHESAPEAKE APPALACHIA LLC Produced Fluid 101.33 Bbl REUSE OTHER THAN ROAD SPREADING
2017 CHESAPEAKE APPALACHIA LLC Other Oil & Gas Wastes 46.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2017 CHESAPEAKE APPALACHIA LLC Produced Fluid 36.67 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC008
2018 CHESAPEAKE APPALACHIA LLC Produced Fluid 8.40 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018 CHESAPEAKE APPALACHIA LLC Produced Fluid 15.10 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC008
2019 CHESAPEAKE APPALACHIA LLC Produced Fluid 0.60 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC008

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1845236 Primary Facility 2009-11-16 Drilling/Alteration No Violations Noted At time of inspection drilling depth at 8586' in middle of lateral. TD proposed to be 11,400'. Operator will be setting 5-1/2" production string at TD. Nomac Rig 112 on site. I met with CO. Man Dorsey Rogers, and Drilling Supt. Hayward White on site.
1846589 Primary Facility 2009-11-30 Follow-up Inspection Violation(s) Noted The discharge line was over-pressurized which caused the rope to break and the hose to come loose. It was reported that approximately 8 barrels of water-based drilling mud was spilled onto the ground. According to Mr. Keith, the spill occurred at approximately 2:00 am on 11/30/09.
1884561 Primary Facility 2010-01-05 Follow-up Inspection Viol(s) Noted & Immediately Corrected
2031980 Primary Facility 2012-01-05 Routine/Complete Inspection No Violations Noted On site 9:15 am. No activity on site. Well is online. No noticeable leaks or gas bubbling in cellar. Security fence partially installed around wells.
2045505 Primary Facility 2011-10-23 Administrative/File Review No Violations Noted Flowback Fluid Spill Notification and Emergency Response Document.
2113651 Primary Facility 2012-11-06 Routine/Partial Inspection Pending During the inspection it was noted that the site appeared to have reached >70% perennial vegetative cover. No E&S controls were found to be installed during the inspection. The plan maps reflect that 18” silt fence was to be installed however the fence was redlined as of 3/17/2010 by “JHF” and18” composite sock was to replace the fence. An additional section of sock was also redlined into the plan in the north side of the well site between the pad and the access road. It was noted on the plan map the the filter sock was removed as of 11/2/2010 with “JR” initials. Geotextile material was noted to be in the area of the removed filter sock. In the course of the inspection, it was noted that areas to the west of the well pad between the pad and the access road had wetlands flagged. The flagged areas do not appear to be detailed on the 11/12/2009 plan maps. Vegetation commonly associated with wetlands was noted within feet of the fill slope.Additionally, it appears that rock and timber were situated in this area.
2359296 Primary Facility 2015-04-08 Routine/Complete Inspection No Violations Noted The Department was on site to conduct a routine complete inspection of the Hunsinger well site. The site was well vegetated and stable. There was no recent E&S Inspection on site.
2361841 Primary Facility 2015-04-16 Routine/Complete Inspection No Violations Noted
2415780 Primary Facility 2015-10-15 Routine/Complete Inspection No Violations Noted
2450168 Primary Facility 2016-02-17 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 9:30 a.m., the cellar was full of water and ice with no bubbling noticed, the (13x9) vent pipe was open and set up with a pop valve with 0psi on it and the valve going to the tank was closed, the was no vent pipe on the (9x5). There was 0psi on the production casing and 900psi on the production line. I took a walk around the location and everything looked OK.

I left the site at 10:10 a.m.

2736887 Primary Facility 2018-05-25 Routine/Complete Inspection No Violations Noted The Department arrived on site at 1230 hrs to conduct a RTNC inspection. The Department was represented by Frank Hoehle (WQS-DEP) and myself.

Proper signage was displayed at the entrance to the access road. The access road was mostly solid and stable. However, several areas containing minor erosion were present on the access road, which the Department recommends be addressed promptly. Water bars were also in place which were slightly deteriorated but functional.

While examining the production fluid tanks on site, the Department noticed that one of the tanks displayed significant corrosion, including pitting, and heavy staining. The Department requests that the deteriorated tank be examined and either replaced or repaired. The Department noticed that a new empty tank was present on site, most likely for this purpose.

The cut slope and fill slope were both well-vegetated and stable with no apparent erosional issues. The pad surface was also solid and stable.

The well heads were all clearly and properly lab

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
1846589 576725 11/30/2009 2009-11-30 601.101 - O&G Act 223-General. Used only when a specific O&G Act code cannot be used Administrative violation 78.56 and SWMA 35 Section 6018.301 cited in NOV dated 11/30/09
1884561 587042 01/05/2010 2010-01-05 601.101 - O&G Act 223-General. Used only when a specific O&G Act code cannot be used Administrative 78.56 Failure to contain a pollutional substance in a lined pit or tank
1884561 587043 01/05/2010 2010-01-05 691.1 - Clean Streams Law-General. Used only when a specific CLS code cannot be used Administrative 691.402 Potential pollution
1884561 587044 01/05/2010 2010-01-05 601.101 - O&G Act 223-General. Used only when a specific O&G Act code cannot be used Administrative 6018.301 Failure to manage a residual waste

For data sources see[8]

References