Well Details

Well ID: 37-081-21577
Loading map...
Country: United States
State: Pennsylvania
County: Lycoming
Municipality: Jackson Township
Operator Name: RANGE RESOURCES APPALACHIA LLC
Well Pad ID: 148742
Farm/Lease Name: LAUREL HILL 25H
License Status:
Spud Date: 2016-05-28
Permit Date: 2015-03-12
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.499269
Longitude: -77.103522

For data sources see[1][2][3]

Well History

Date Event
Deviated
2015-03-12 New Permit Application
2016-02-03 Permit Renewal Application
2016-05-28 Performed Spud Operation
2016-07-29 Drilling Completion

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2016-09-20 2016-09-30 8,731 2,942,960

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Water Range Resources Base/Carrier Fluid Listed Below
Dodecamethylcyclohexasiloxane 540-97-6 0.00001000 0.00001000
Neutralized Polycarboxlic Acid Proprietary 10 0.00189
Urea 57-13-6 0.00288 0.00058
Acetophenone 98-86-2 0.00008000 0.00002000
Alcohols, C10-16, ethoxylated 68002-97-1 0.00021 0.00004000
Polymer of 2-acrylamido-2-methylpropanesulfonic
acid sodium salt and methyl acrylate
136793-29-8 0.00469 0.00095
Siloxanes and silicones, dimethyl,
reaction products with silica
67762-90-7 0.00001000 0.00001000
Silicon Dioxide 7631-86-9 0.0006 0.00012
Potassium chloride 7447-40-7 0.00078 0.00016
Dimethyl siloxanes and silicones 63148-62-9 0.00004000 0.00001000
2-Propenamid (impurity) 79-06-1 0.00014 0.00003000
Reaction product of: acetophenone,
formaldehyde, cyclohexylamine,
methanol and acetic acid
224635-63-6 0.00075 0.00015
Octamethylcyclotetrasiloxane 556-67-2 0.00001000 0.00001000
Sodium erythorbate 6381-77-7 0.00272 0.00055
Acrylamide, 2-acrylamido-2-methylpropanesulfonic
acid, sodium salt polymer
38193-60-1 0.04376 0.00887
Copper(II) sulfate 7758-98-7 0.00001000 0.00001000
Alcohol, C9-C11, Ethoxylated 68439-46-3 0.00031 0.00006000
Acetic acid(impurity) 64-19-7 0.00008000 0.00002000
Methanol 67-56-1 0.00182 0.00037
Tetrasodium ethylenediaminetetraacetate 64-02-8 0.00007000 0.00002000
Sodium sulfate 7757-82-6 0.00067 0.00014
Calcium chloride 10043-52-4 0.01329 0.00269
Sodium Nitrate 7631-99-4 5 0.00043
Cinnamaldehyde 104-55-2 0.00042 0.00008000
Hydrochloric Acid 7647-01-0 0.36403 0.0738
Sodium chloride 7647-14-5 0.00024 0.00005000
Water 7732-18-5
Amines, tallow alkyl, ethoxylated 61791-26-2 0.00006000 0.00001000
Crystalline Silica 14808-60-7 99.5029 20.1717
Sodium chloride 7647-14-5 60 0.0052
Calcium Nitrate 13477-34-4 60 0.07341
Water 7732-18-5 100 79.7275
Non-Hazardous Solvent Package Proprietary 50 0.00945
Decamethyl cyclopentasiloxane 541-02-6 0.00001000 0.00001000
Formaldehyde (impurity) 50-00-0 0.00005000 0.00001000
Ammonium sulfate 7783-20-2 0.0593 0.01202
MX 5-3886 MultiChem Antibacterial Listed Below
MX 588-2 MultiChem Scale Inhibitor Listed Below
MX 8-2544 MultiChem Antibacterial Listed Below
H315 (HCL Acid) Schlumberger Cleans Perforations Listed Below
J609W, L058, A264A Schlumberger Prevents corrosion inpipe, Prevents iron buildup, Reduces friction between fluid and pipe Listed Below
S012-4070, S100 (Sand) Schlumberger Proppant Listed Below

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2016 RANGE RESOURCES APPALACHIA LLC 316,219.17 74 0.00 0 0.00 0
2017 RANGE RESOURCES APPALACHIA LLC 768,837.85 358 0.00 0 0.00 0
2018 RANGE RESOURCES APPALACHIA LLC 445,349.07 365 0.00 0 0.00 0
2019 RANGE RESOURCES APPALACHIA LLC 380,326.86 365 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2016 RANGE RESOURCES APPALACHIA LLC Other Oil & Gas Wastes 129.61 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2016 RANGE RESOURCES APPALACHIA LLC Produced Fluid 1,190.94 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2016 RANGE RESOURCES APPALACHIA LLC Drilling Fluid Waste 480.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 RANGE RESOURCES APPALACHIA LLC Drilling Fluid Waste 183.52 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2016 RANGE RESOURCES APPALACHIA LLC Drill Cuttings 1,111.34 Tons LANDFILL 301358
2016 RANGE RESOURCES APPALACHIA LLC Other Oil & Gas Wastes 266.33 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2016 RANGE RESOURCES APPALACHIA LLC Produced Fluid 6,377.16 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2017 RANGE RESOURCES APPALACHIA LLC Produced Fluid 2,541.55 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2017 RANGE RESOURCES APPALACHIA LLC Other Oil & Gas Wastes 139.15 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2017 RANGE RESOURCES APPALACHIA LLC Other Oil & Gas Wastes 324.46 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2017 RANGE RESOURCES APPALACHIA LLC Produced Fluid 677.11 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2018 RANGE RESOURCES APPALACHIA LLC Produced Fluid 1,316.85 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018 RANGE RESOURCES APPALACHIA LLC Produced Fluid 109.29 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2018 RANGE RESOURCES APPALACHIA LLC Other Oil & Gas Wastes 51.44 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2019 RANGE RESOURCES APPALACHIA LLC Produced Fluid 72.00 Bbl RESIDUAL WASTE TRANSFER FACILITY WMGR123NC039
2019 RANGE RESOURCES APPALACHIA LLC Produced Fluid 360.11 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2019 RANGE RESOURCES APPALACHIA LLC Produced Fluid 202.00 Bbl REUSE (AT WELL PAD)
2019 RANGE RESOURCES APPALACHIA LLC Other Oil & Gas Wastes 2.38 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2019 RANGE RESOURCES APPALACHIA LLC Other Oil & Gas Wastes 6.28 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2019 RANGE RESOURCES APPALACHIA LLC Produced Fluid 165.01 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2368862 Primary Facility 2015-04-28 Incident- Response to Accident or Event No Violations Noted At 09:02, I met with Zachary Subra, Randi Mathew, and JJ Magyar (all Range Resources) on the Laurel Hill 1H well pad. The release of produced water had sprayed from the production tank southeast onto the pad. The spill was cleaned up except for the area immediately beneath the stairs. The stairs for the production tank were moved and impacted material was removed from underneath the stairs. The highest field conductivity noted was 580 umhos/cm. Violations Noted and Immediately Corrected.
2503883 Primary Facility 2016-07-20 Routine/Complete Inspection No Violations Noted Routine Inspection; 7/20/2016.

Jared Rutt (DEP) and I entered the site at approximately 08:45 and walked the site. At the time of the inspection, the Sidewinder 61 was onsite drilling the Laurel Hill 25H (081-21577). The containment on the west side of the drill rig near the cuttings mixing/unloading area had very little berm and appeared to be inadequate. The berm around the drilling additives containment had holes and was not effective. I asked the company man to move the drilling additives onto containment or fix the containment where the additives are currently being stored. The company man and Range representatives worked to fix the containment and on 7/21/2016 I received photos of the containment after it was repaired (attached). In addition, Sean VanFleet inspected the site on 7/21/2016 and reported the containment was in the process of being improved.

Currently, the site has not been restored and the ESCGP is expired. I recommend re-permitting the site with a new ESCGP-2 which contains Post

2526923 Primary Facility 2016-10-07 Routine/Complete Inspection No Violations Noted
2527624 Primary Facility 2016-10-13 Incident- Response to Accident or Event Violation(s) Noted
2578365 Primary Facility 2017-03-31 Incident- Response to Accident or Event No Violations Noted
2587459 Primary Facility 2017-04-26 Follow-up Inspection No Violations Noted
2643956 Primary Facility 2017-10-04 Routine/Complete Inspection No Violations Noted Whether was 52° and sunny at time of inspection. 5 1/2 x 9 5/8 annulus was plumbed to a poly tank. Poly tank had 0% combustible gas detected at time of inspection. 9 5/8 x 13 3/8 anulus is plumbed surface and had 0% combustible gas detected at time of inspection. There was no 13 3/8 x 20 annulus valve observed at time of inspection. There was a 0 to 5000 PSI gauge attached above the swab valve that read approximately 1100 PSI at time of inspection.
2774610 Primary Facility 2018-09-13 Routine/Complete Inspection No Violations Noted Five wells staged for production phase. Five each water separators. Two sand separators. No leaks detected from production equipment. Methanol tanks located near well hea

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2527624 770347 2016-10-13 2017-01-27 78.54 Environmental Health & Safety Operator reported a >5 gallon release of reuse water (produced water, flowback) through failed patches in containment. Area was vacced and scraped; followup by inspector found elevated conductance still prevailed in this area.
2527624 770348 2016-10-13 2017-01-27 CSL 402(b) Environmental Health & Safety Operator reported a >5 gallon release of reuse water (produced water, flowback) through failed patches in containment. Area was vacced and scraped; followup by inspector found elevated conductance still prevailed in this area.
2527624 770349 2016-10-13 2017-01-27 SWMA 301 Environmental Health & Safety Operator reported a >5 gallon release of reuse water (produced water, flowback) through failed patches in containment. Area was vacced and scraped; followup by inspector found elevated conductance still prevailed in this area.

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
770347 347837 NOV - Notice of Violation 2017-03-09
770348 347837 NOV - Notice of Violation 2017-03-09
770349 347837 NOV - Notice of Violation 2017-03-09

For data sources see[8]