If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-015-21750 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.625581,"lon":-76.476589,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Bradford | |
Municipality: Monroe Township | |
Operator Name: CHIEF OIL & GAS LLC | |
Well Pad ID: 150567 | |
Farm/Lease Name: KINGSLEY UNIT A 3H | |
License Status: | |
Spud Date: | |
Permit Date: 2011-06-28 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.625581 | |
Longitude: -76.476589 |
Date | Event |
---|---|
2011-06-28 | New Permit Application |
2011-11-16 | Performed Spud Operation |
2012-03-09 | Perforation |
2014-08-01 | DEVIATED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2012-03-17 | 2012-03-17 | 9,033 | 1,506,288 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Fresh Water | Base Fluid | ||||||
Fresh Water | 100.00 | 84.99 | ||||||
Hydrochloric Acid 10-33 | Frac Tech Services (FTS) | Acid | Water | 7732-18-5 | ||||
Hydrochloric acid | 7647-01-0 | 0.79 | ||||||
Sand (Proppant) | Frac Tech Services (FTS) | Propping Agent | Quartz | 14808-60-7 | 99.90 | 14.85 | ||
Scale Inhibitor - Gyptron T-390 | Champion Technologies | Scale Inhibitor | ||||||
Methanol | 67-56-1 | 0.01 | ||||||
Biocide - Bactron K 139 | Champion Technologies | Biocide | Ethanol | 64-17-5 | ||||
benzyl-C12-16 alkyldimethyl,chlorides | ||||||||
Quaternary ammonium compounds, benzyl-C12-16-alkyldimethyl, chlorides |
68424-85-1 | |||||||
Glutaraldehyde | 111-30-8 | 0.04 | ||||||
FRW-600 | Frac Tech Services (FTS) | Friction Reducer | ||||||
Distillates, petroleum, hydrotreated light | 64742-47-8 | 0.10 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2011 | CHIEF OIL & GAS LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | CHIEF OIL & GAS LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2013 | CHIEF OIL & GAS LLC | 3,058,071.00 | 233 | 0.00 | 0 | 0.00 | 0 |
2014 | CHIEF OIL & GAS LLC | 1,466,147.00 | 275 | 0.00 | 0 | 0.00 | 0 |
2015 | CHIEF OIL & GAS LLC | 1,473,304.18 | 363 | 0.00 | 0 | 0.00 | 0 |
2016 | CHIEF OIL & GAS LLC | 1,564,934.53 | 363 | 0.00 | 0 | 0.00 | 0 |
2017 | CHIEF OIL & GAS LLC | 1,279,601.40 | 365 | 0.00 | 0 | 0.00 | 0 |
2018 | CHIEF OIL & GAS LLC | 1,097,287.54 | 365 | 0.00 | 0 | 0.00 | 0 |
2019 | CHIEF OIL & GAS LLC | 1,109,197.85 | 365 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2012 | CHIEF OIL & GAS LLC | Drill Cuttings | 2,520.50 Tons | LANDFILL | 301358 |
2012 | CHIEF OIL & GAS LLC | Drilling Fluid Waste | 774.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | EPA ID: 748-163 |
2012 | CHIEF OIL & GAS LLC | Fracing Fluid Waste | 1,320.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012 | CHIEF OIL & GAS LLC | Drilling Fluid Waste | 75.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | CHIEF OIL & GAS LLC | Produced Fluid | 835.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | CHIEF OIL & GAS LLC | Fracturing Fluid Waste | 13.54 Tons | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC006 |
2014 | CHIEF OIL & GAS LLC | Produced Fluid | 1,562.46 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | CHIEF OIL & GAS LLC | Produced Fluid | 183.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
2015 | CHIEF OIL & GAS LLC | Produced Fluid | 4,213.97 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | CHIEF OIL & GAS LLC | Produced Fluid | 1,438.07 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2017 | CHIEF OIL & GAS LLC | Produced Fluid | 48.79 Bbl | STORAGE PENDING DISPOSAL OR REUSE | |
2017 | CHIEF OIL & GAS LLC | Produced Fluid | 347.58 Bbl | REUSE (AT WELL PAD) | |
2018 | CHIEF OIL & GAS LLC | Produced Fluid | 1.84 Bbl | REUSE (AT WELL PAD) | |
2019 | CHIEF OIL & GAS LLC | Produced Fluid | 206.30 Bbl | REUSE (AT WELL PAD) |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2021532 | Primary Facility | 2011-11-22 | Drilling/Alteration | No Violations Noted | Cellar is constructed. 20" cond. set. No well ID. |
2030163 | Primary Facility | 2011-12-21 | Drilling/Alteration | No Violations Noted | UDI Rig 207, Comp. Man - Tony Tripp at 550', going back in hole. |
2032621 | Primary Facility | 2012-01-06 | Drilling/Alteration | No Violations Noted | All spilled sand pumpings on containment but for approx. 4-5 gal cheif picked up all effected ground material and disposed of properly. |
2037388 | Primary Facility | 2012-01-26 | Drilling/Alteration | No Violations Noted | UDI 207, Comp Man - Tony Tripp |
2040246 | Primary Facility | 2012-02-06 | Drilling/Alteration | Violation(s) Noted | UDI 207, Comp. Man - Jim Quisenbury, @ 9611' |
2051597 | Primary Facility | 2012-03-09 | Drilling/Alteration | No Violations Noted | Comp. Man - Bill Burton |
2092517 | Primary Facility | 2012-07-25 | Routine/Complete Inspection | No Violations Noted | Water in cellar, no bubbles. |
2478777 | Primary Facility | 2016-04-26 | Routine/Complete Inspection | No Violations Noted | |
2485999 | Primary Facility | 2016-05-17 | Site Restoration | No Violations Noted | |
2563440 | Primary Facility | 2017-02-21 | Routine/Complete Inspection | No Violations Noted | |
2602434 | Primary Facility | 2017-06-08 | Routine/Complete Inspection | No Violations Noted | Three wells in production status. One well not in production. Three water separators within containment. No leaks detected from production equipment. Petroleum substance within 2H Well celler. No violations cited at this time. |
2717028 | Primary Facility | 2018-03-15 | Routine/Complete Inspection | No Violations Noted | Arrived at 11:00 with Jon Hafer to conduct inspection for regulatory inactive well status extension request. This is the second extension request for this well. The 9-5/8" x 5-1/2" annulus was open and vented to a 550- gallon polytank where no methane was detected. The 20" x 13-3/8" and 13-3/8" x 9-5/8" annuli could not be observed because the cellar was filled with gravel. Requested a follow- up inspection with the cellar vacced out to observe these annuli. The three other wells onsite were in production. No violations were observed at the time of this inspection. |
2789047 | Primary Facility | 2018-10-12 | Routine/Complete Inspection | No Violations Noted | Three wells are staged for production. Well cellars are filled with pea gravel. Three GPUs are present within felt and plastic containment. Three steel produced water tanks are present and in good condition. Steel containment with spray-in liner is present and in good condition. Approximately one foot of water are present within containment. The conductivity here was 29.9 uS/cm.
The majority of the pad surface has been restored and is well-vegetated with greater than 70% vegetation. A gravel path exists to the well heads, produced water tanks, and GPUs. Temporary BMPs have been removed. Pad side slopes and topsoil stockpile are well-vegetated with greater than 70% vegetation as well. Site is stable. No violations noted. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
2040246 | 631306 | 02/06/2012 | 2012-02-06 | 78.122 - Drillers Log not on site | Administrative |
Violation ID | Penalty ID | Penalty Code | Penalty Status | Penalty Date | Enforcement Date | Penalty Amount | Amount Collected |
---|---|---|---|---|---|---|---|
631306 | 280423 | NOV - Notice of Violation | Administrative Close Out | 2012-02-20 |
For data sources see[8]