37-015-21516

Well Details

Well ID: 37-015-21516
Loading map...
Country: United States
State: Pennsylvania
County: Bradford
Municipality: Warren Township
Operator Name: REPSOL OIL & GAS USA LLC
Well Pad ID: 149617
Farm/Lease Name: YOUNG 05 080 03 R
License Status: Active
Spud Date:
Permit Date: 2011-01-24
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.934228
Longitude: -76.194975

For data sources see[1][2][3]

Well History

Date Event
2011-01-24 New Permit Application
2012-01-23 Permit Renewal Application
2013-01-05 Performed Spud Operation
2015-11-12 Inactive Well Request Granted
2015-12-01 DEVIATED
2016-03-05 Perforation
2016-03-11 Performed Stage 1 of Stimulation
2016-03-12 Perforation
2016-03-12 Performed Stage 2 of Stimulation
2016-03-12 Performed Stage 3 of Stimulation
2016-03-12 Performed Stage 4 of Stimulation
2016-03-13 Perforation
2016-03-13 Performed Stage 5 of Stimulation
2016-03-13 Performed Stage 6 of Stimulation
2016-03-13 Performed Stage 7 of Stimulation
2016-03-14 Perforation
2016-03-14 Performed Stage 10 of Stimulation
2016-03-14 Performed Stage 8 of Stimulation
2016-03-14 Performed Stage 9 of Stimulation
2016-03-15 Perforation
2016-03-15 Performed Stage 11 of Stimulation
2016-03-15 Performed Stage 12 of Stimulation
2016-03-15 Performed Stage 13 of Stimulation
2016-03-15 Performed Stage 14 of Stimulation
2016-04-10 Perforation

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2016-03-11 2016-03-15 5,928 2,940,760 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Fresh Water Operator Base Fluid Fresh Water 7732-18-5 100 80.7401 24,525,800.0
Hazardous and Non-Hazardous Ingredients Crystalline silica, quartz 14808-60-7 100 18.4064 5,591,180.0
Olefins Confidential 5 0.00007901 24
Telomer Confidential 10 0.00214641 652
Alkyl (C12-16) dimethylbenzylammonium chloride 68424-85-1 5 0.000971152 295
Hydrotreated light petroleum distillate 64742-47-8 30 0.0217571 6609
Water 7732-18-5 100 0.815313 247662
Glutaraldehyde 111-30-8 30 0.00582033 1768
Polyacrylate Proprietary 30 0.0217571 6609
Sobitan, mono-9-octadecenoate, (Z) 1338-43-8 5 0.00362783 1102
Acrylic acid 79-10-7 0.01 0.00000329 1
Methanol 67-56-1 60 0.000381877 116
Ethylene glycol 107-21-1 60 0.0128719 3910
9-Octadecenamide, n,n-bis-2(hydroxy-ethyl)-,(Z) 93-83-4 5 0.00362783 1102
Hydrochloric acid 7647-01-0 60 0.443714 134784
Phosphoric acid 7664-38-2 0.1 0.00001975 6
Ammonium chloride 12125-02-9 5 0.00362783 1102
Propargyl alcohol 107-19-7 10 0.00006584 20
Castor oil, ethoxylated 61791-12-6 5 0.00362783 1102
Fatty acids, tall oil Confidential 30 0.000190938 58
Sodium polyacrylate 9003-04-7 1 0.000213983 65
Ethoxylated alcohols Proprietary 30 0.000190938 58
Sodium chloride 7647-14-5 5 0.00362783 1102
Modified thiourea polymer Proprietary 30 0.000190938 58
Ethyl alcohol 64-17-5 1 0.00019423 59

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2016-03-11 1 White 2,860,872 7,881 9,419
2016-03-12 2 White 2,860,872 8,439 8,944
2016-03-12 3 White 2,860,872 8,452 9,077
2016-03-12 4 White 2,860,872 8,300 8,950
2016-03-13 5 White 2,860,872 8,189 8,839
2016-03-13 6 White 2,860,872 8,265 8,793
2016-03-13 7 White 2,860,872 7,840 9,317
2016-03-14 8 White 2,860,872 7,958 8,733
2016-03-14 9 White 2,860,872 7,878 8,477
2016-03-14 10 White 2,860,872 7,888 9,040
2016-03-15 11 White 2,860,872 8,043 8,955
2016-03-15 12 White 2,860,872 7,989 8,583
2016-03-15 13 White 2,860,872 7,611 8,371
2016-03-15 14 White 2,860,872 7,919 8,907

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 REPSOL OIL & GAS USA LLC 0.00 0 0.00 0 0.00 0
2011 REPSOL OIL & GAS USA LLC 0.00 0 0.00 0 0.00 0
2012 REPSOL OIL & GAS USA LLC 0.00 0 0.00 0 0.00 0
2013 REPSOL OIL & GAS USA LLC 0.00 0 0.00 0 0.00 0
2014 REPSOL OIL & GAS USA LLC 0.00 0 0.00 0 0.00 0
2015 REPSOL OIL & GAS USA LLC 0.00 0 0.00 0 0.00 0
2016 REPSOL OIL & GAS USA LLC 367,130.40 266 0.00 0 0.00 0
2017 REPSOL OIL & GAS USA LLC 285,978.20 314 0.00 0 0.00 0
2018 REPSOL OIL & GAS USA LLC 263,353.30 361 0.00 0 0.00 0
2019 REPSOL OIL & GAS USA LLC 215,698.40 361 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2013 REPSOL OIL & GAS USA LLC Drill Cuttings 789.25 Tons LANDFILL 8-0728-0004/013
2016 REPSOL OIL & GAS USA LLC Fracturing Fluid Waste 33.18 Tons LANDFILL 100361
2016 REPSOL OIL & GAS USA LLC Fracturing Fluid Waste 13,410.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 REPSOL OIL & GAS USA LLC Produced Fluid 1,943.39 Bbl REUSE OTHER THAN ROAD SPREADING
2016 REPSOL OIL & GAS USA LLC Synthetic Liner Materials 45.69 Tons LANDFILL 8-0728-0004/013
2016 REPSOL OIL & GAS USA LLC Fracturing Fluid Waste 1,238.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2016 REPSOL OIL & GAS USA LLC Produced Fluid 832.07 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2017 REPSOL OIL & GAS USA LLC Produced Fluid 161.79 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2017 REPSOL OIL & GAS USA LLC Produced Fluid 1,775.89 Bbl REUSE (AT WELL PAD)
2018 REPSOL OIL & GAS USA LLC Produced Fluid 369.61 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018 REPSOL OIL & GAS USA LLC Produced Fluid 1,220.09 Bbl REUSE (AT WELL PAD)
2019 REPSOL OIL & GAS USA LLC Produced Fluid 831.97 Bbl REUSE (AT WELL PAD)

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2128806 Primary Facility 2012-12-13 Routine/Complete Inspection Violation(s) Noted 1/3 of pad covered by muddy water originating from the drilling activity. Further investigation revealed what appeared to be an oily sheen on the surface of this muddy water located in the vicinity of the partially assembled manifold for the production gas. Fortunately, dirt berms located along the edge of the pad was keeping the muddy water and oil sheen on the pad. Told drill crew that they needed to immediately contact talisman and get guidance on how to clean up this spill. This is also a violation of 25 Pa Code 78.60
2128837 Primary Facility 2013-01-07 Follow-up Inspection No Violations Noted Inspection conducted on 1/7/13 of the Talisman Young Pad. Inspection is being conducted to collect and split samples with Talisman. soil samples were collected from 2 locations on the eastern section of the pad in the vicinity of the partially completed production manifold. The temporary containment was poorly designed and constructed.
2142739 Primary Facility 2013-01-07 Drilling/Alteration No Violations Noted Conductor set at 239'
2151630 Primary Facility 2013-03-28 Administrative/File Review No Violations Noted Talimans results revealed the top hole water did not have any petroleum present. Talisman also evaluated pH and conductance of the water and found it to be within the parameters outlined in 78.60. Talisman then requested to discharge this top hole water wihich was subsequently approved. As a precautionary measure, the Department collected soil samples on the well pad. Results revealed no organic contamination. Talisman also conducted soil sampling and concluded no organic contamination present at the time of sampling. Talisman has indicated that they have improved their water managementy procedures as a result of this incident. Talisman is reminded that strict adherence of their submitted PPC plan would have prevented this incident. With no identified environmental impact obsereved, the Departmemt does not plan on taking any further action at this time.
2258942 Primary Facility 2014-04-01 Complaint Inspection No Violations Noted
2268207 Primary Facility 2014-04-30 Complaint Inspection No Violations Noted
2309170 Primary Facility 2014-09-30 Complaint Inspection No Violations Noted
2464489 Primary Facility 2016-03-14 Complaint Inspection No Violations Noted Complainant reported a white powdery substance possibly silica sand used for fracking. conducted an inspection on 3/14/2016 during the inspection there were no issues violations noted.
2464516 Primary Facility 2016-03-08 Complaint Inspection No Violations Noted
2466975 Primary Facility 2016-03-14 Complaint Inspection No Violations Noted
2467576 Primary Facility 2016-03-21 Incident- Response to Accident or Event No Violations Noted
2475232 Primary Facility 2016-03-24 Routine/Complete Inspection No Violations Noted Shortly upon arrival we met with Tony Baker, Completions Foreman, of Talisman Energy. Mr. Baker stated the following. "Talisman is in the process of setting up for flowback operations for the Young 3H well and they been waiting for a magnesium ball valve to dissolve in tubing in the wellbore in order to commence flowback of the well. Hydraulic fracturing operations were completed by Halliburton as of 3/15/16. Frac plug drill-outs were completed by Basic Well Services on 3/15/16".

We observed a small area of dark staining on the perimeter earthen berm of the site above a sediment trap. We also observed a piece of secondary containment liner with spots of dark staining staged on the pad surface next to the pad berm above the sediment trap. I recorded 0.84 milliSiemens/cm³ conductivity in water on containment behind frac tanks in a tank battery near the pad perimeter berm and top of the fill slope of the site.

2626388 Primary Facility 2017-08-01 Routine/Complete Inspection No Violations Noted On August 1, 2017, the Department conducted a routine inspection at the Repsol Oil and Gas USA LLC, Young R (05-080) well site in Warren Township, Bradford County. The Department was represented by Andrew Hobbins, Water Quality Specialist. Nobody was present for Repsol.

The site sign, E & S plan and weekly inspection logs were on site and available for review. The site was well vegetated and no major erosion or sedimentation issues were observed. A small area lacking vegetation with minor erosion was observed at the outlet of the infiltration area. This is most likely the result of recent heavy rainfall in the area. The Department recommends repairing and reseeding the area.

Two wells were in production on the well pad. The wells were labeled and no bubbling was observed in the well cellar. Two production tanks and two GPUs were on secondary containment. The containment structures were observed to be in good condition. Specific conductivity readings were taken from puddles on the pad and from

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2128806 657266 12/13/2012 2012-12-13 402CSL - Failure to adopt pollution prevention measures required or prescribed by DEP by handling materials that create a danger of pollution. Environmental Health & Safety

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
657266 292356 NOV - Notice of Violation Comply/Closed 2013-03-28

For data sources see[9]