X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-167-28619

Well Details

Well ID: 34-167-28619
Loading map...
Country: United States
State: Ohio
County: Washington
Municipality: Wesley Township
Operator Name: AM-TEK OIL INC
Well Pad ID:
Farm/Lease Name: GAGE A
License Status: Producing
License Date: 1988-12-15
Spud Date: 1989-01-03
Spud Drilling Contractor: KRACO
Final Drill Date: 1989-01-09
Well Total Depth: 5297.00 ft
Configuration: Vertical
Latitude: 39.430000
Longitude: -81.780000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1988-12-15 Issued Date 12/15/88 Expired Date 12/15/89 Acres 0040000 Tool Type RTA Proposed Formation CLINTON/MEDI Proposed Depth 05297 Proposed Drill Depth 05297
Original Spud 1989-01-03
Completed 1989-01-09
Reached Total Depth 1989-01-09
CO 1989-01-16 45 G W F CORPORATION GeoDate 12/15/88
Completion Report Received 1989-02-27
Construction Permit Expires 1989-12-15
CO 1994-01-07 2348 TRIAD RESOURCES INC GeoDate 12/15/88
Change of Owner 2006-02-08 Operator changed from 2348, TRIAD RESOURCES INC to 2657, STAR OIL & GAS
Change of Owner 2006-02-22 Operator changed from 2657, STAR OIL & GAS to 516, MURPHY OIL CO
Change of Owner 2017-04-14 Operator changed from 516, MURPHY OIL COMPANY INC to 9651, AM-TEK OIL INC
Last Compliance Report 2017-08-22
Record Last Modified 2017-08-22

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 5126 5134 9
5070 5134 0
2006-09-11 5999 5205 5
5126 5134 9
5070 5134 0
1997-06-29 5070 5134 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
GEL 0 20 Lbs 70000 LTD ENTRY FRAC:SAND/WATER
H2O 0 67000 Gal 0

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1989 G W F CORPORATION 9769.00 55.00 365
1990 G W F CORPORATION 5343.00 60.00 365
1995 TRIAD RESOURCES INC 417.00 38.00 365
1996 TRIAD RESOURCES INC 231.00 25.00 366
1997 DERRICK INDUSTRIES INC 253.00 0.00 365
1998 STAR OIL & GAS 1988.00 78.00 365
2001 TRIAD RESOURCES INC 0.00 0.00 365
2003 TRIAD RESOURCES INC 0.00 0.00 365
2004 TRIAD RESOURCES INC 0.00 0.00 365
2005 TRIAD RESOURCES INC 0.00 0.00 365
2013 MURPHY OIL COMPANY INC 0.00 0.00 0
2014 MURPHY OIL COMPANY INC 0.00 0.00 0
2016 MURPHY OIL COMPANY INC 0.00 0.00 0
2017 MURPHY OIL COMPANY INC 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1989 G W F CORPORATION Brine 114 365
1990 G W F CORPORATION Brine 80 365
1995 TRIAD RESOURCES INC Brine 18 365
1996 TRIAD RESOURCES INC Brine 20 366
1997 DERRICK INDUSTRIES INC Brine 0 365
1998 STAR OIL & GAS Brine 30 365
2001 TRIAD RESOURCES INC Brine 0 365
2003 TRIAD RESOURCES INC Brine 0 365
2004 TRIAD RESOURCES INC Brine 0 365
2005 TRIAD RESOURCES INC Brine 0 365
2013 MURPHY OIL COMPANY INC Brine 0 0
2014 MURPHY OIL COMPANY INC Brine 0 0
2016 MURPHY OIL COMPANY INC Brine 0 0
2017 AM-TEK OIL INC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-2100338951 2010-12-6 0:00: AM No Violations 0.30
-325110981 2017-6-5 0:00:0 TD No Violations 1.00
-354347214 2006-2-7 0:00:0 AD No Violations
-81015970 2018-8-30 0:00: PW No Violations 1.00
-847261537 2020-5-1 0:00:0 PW No Violations 0.90
0081015970 2018-08-30 Production Wells No Violations The well was placed back into production. The well pumped while I was on location. The tank battery was moved at the request of the previous Inspector. I had Andrew place two plugs into the loading lines of the tank. The well is equipped with a pumping unit, tubing, rods and a natural gas motor equipped with a timer. All previous violations have been resolved.
0325110981 2017-06-05 Temporary Abandoned Annular Disposal No Violations The inspection this day found this well is equipped with 4 1/2 inch diameter production casing and 1 1/2 inch diameter production tubing. The inspection found that the TAAD for this well is not hooked up. There are no issues to report at this time.
0354347214 2006-02-07 Annular Disposal No Violations Inspection this day found well not in production. No annular disposal, even when producing.
0658635669 2006-02-07 Production Wells Violations Noted Inspection this day found well not in production, landowner says hasnt produced in years, old, faded chart in meter, tank has no IDs. No annular disposal
1196142214 2012-08-27 Administrative Inspection No Violations

- would like to keep them out. I looked up production reported which was 1998 and gave Stan that information. Unfortunately, Broad Street has several producing wells on the acerage and the lease is not very specific. He said he would call Sheriff to keep them off property and I said that was about all he could do - could also consult a lawyer.

1650384362 2008-07-23 Production Wells No Violations Crew has cut road to well, laid some new line but well still not producing, landowner says they moved separator, will have to get rig in to work on well.
1882959992 2009-10-30 Production Wells No Violations NOV resolved. Inspection this day found well producing thru casing, tank has poor dike, asked pumper to get IDs up - has 2 sets of tanks - one at well and one up at road.
2100338951 2010-12-06 Administrative Inspection No Violations Call today from Stanley Gage, landowner, letting me know he has ordered operator off his property. Richard Johnson of Logan Energy, owner of the well, was slow to pay landowner check, Stanley says lied to him and wont let him produce the well. Told him he needed to contact lawyer and see what his rights were.
658635669 2006-2-7 0:00:0 PW No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0658635669 US-OH-127461 2006-02-10 Failure to legibly identify well
0658635669 US-OH-127462 2006-02-10 Well shall be plugged

For data sources see[9]

References