34-155-23848

Well Details

Well ID: 34-155-23848
Loading map...
Country: United States
State: Ohio
County: Trumbull
Municipality: Bazetta Township
Operator Name: DUSTIN ENERGY INC
Well Pad ID:
Farm/Lease Name: PERRIS UNIT
License Status: Producing
License Date: 2007-02-12
Spud Date: 2007-03-21
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2007-03-25
Well Total Depth: 4728.00 ft
Configuration: Vertical
Latitude: 41.300000
Longitude: -80.720000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2007-02-12 Proposed Formations:CLINTON, Issued Date:2/12/2007, Expired Date:2/12/2008 6:00:00 AM, Drilling unit acres:52.145, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2007-03-25
Construction Permit Expires 2008-02-12
Completion Report Received 2010-12-01
Record Last Modified 2017-10-24

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2011-02-25 4482 4582 47
4482 4582 47
4482 4582 47

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 15 2100 Bbl 60000 185M SCF NITROGEN ASSIST

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2007 DUSTIN ENERGY INC 69.00 92.00 120
2008 DUSTIN ENERGY INC 25845.00 251.00 365
2009 DUSTIN ENERGY INC 11165.00 70.00 365
2010 DUSTIN ENERGY INC 8871.00 112.00 365
2011 DUSTIN ENERGY INC 7632.00 53.00 365
2012 DUSTIN ENERGY INC 5615.00 0.00 366
2013 DUSTIN ENERGY INC 4488.00 0.00 365
2014 DUSTIN ENERGY INC 1721.00 0.00 365
2015 DUSTIN ENERGY INC 5264.00 67.00 365
2016 DUSTIN ENERGY INC 4714.00 0.00 365
2017 DUSTIN ENERGY INC 3987.00 0.00 365
2018 DUSTIN ENERGY INC 4026.00 80.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2007 DUSTIN ENERGY INC Brine 554 120
2008 DUSTIN ENERGY INC Brine 45 365
2009 DUSTIN ENERGY INC Brine 50 365
2010 DUSTIN ENERGY INC Brine 38 365
2011 DUSTIN ENERGY INC Brine 10 365
2012 DUSTIN ENERGY INC Brine 0 366
2013 DUSTIN ENERGY INC Brine 0 365
2014 DUSTIN ENERGY INC Brine 0 365
2015 DUSTIN ENERGY INC Brine 0 365
2016 DUSTIN ENERGY INC Brine 0 365
2017 DUSTIN ENERGY INC Brine 0 365
2018 DUSTIN ENERGY INC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1511684205 2015-2-23 0:00: UP No Violations 0.50
-772953355 2012-10-3 0:00: UP No Violations 0.50
-909814929 2011-3-19 0:00: PW No Violations
0772953355 2012-10-03 UrbanProduction Wells No Violations I completed an urban production well inspection status check. My inspection found the well equipped with a plunger lift unit surrounded by a chain link fence. The tank battery was surrounded by a chain link fence and contained one, 100 barrel oil storage tank, one, 50 barrel brine storage tank, a separator, and the proper identification. The production equipment had the proper spacing. I notice no visible spills or leaks. The lease road was in good condition. There are violations at this time.
0909814929 2011-03-19 Production Wells No Violations Waterwell Complaint , Paul Tanner [landowner] . Inspection showed annulus of production casing was closed . When company opened annulus it flowed approx. .75 bbl of fluid till there was 0 psi on annulus . There was approx. 40 psi on annulus . Well is located 2948 S-E of waterwell in question . I checked well on 3-21-2011 , there was still 0 psi on annulus .
1178009571 2011-08-05 Preliminary Restoration No Violations PreliminaryRestoration meets all requirements.
1511684205 2015-02-23 UrbanProduction Wells No Violations I was on location for a status check. During my inspection, I found the well in production. The well was equipped with a plunger lift assembly. A domestic gas line came off of the 4.5 casing. The tank battery consisted of a 100 barrel production tank, a 50 barrel, poly brine tank and a mechanical separator. A dike surrounded the tank battery. An identification sign was properly posted. There was a plug on the load line. Locked, chain link fences with barb wire surrounded the well and tank battery. The lease road was in stable condition. The well was placed into production prior to House Bill 278.

For data sources see[9]