Well Details

Well ID: 34-155-22709
Loading map...
Country: United States
State: Ohio
County: Trumbull
Municipality: Hartford Township
Operator Name: BIG SKY ENERGY INC
Well Pad ID:
Farm/Lease Name: MBC PROPERTIES
License Status: Producing
License Date: 1990-11-23
Spud Date: 1985-01-29
Spud Drilling Contractor: PERKINS DRLG
Final Drill Date: 1985-02-02
Well Total Depth: 4966.00 ft
Configuration: Vertical
Latitude: 41.320000
Longitude: -80.570000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1984-12-18 Issued Date 12/18/84 Expired Date 6/16/85 Acres 0040000 Tool Type RTA Proposed Formation CLINTON Proposed Depth 04966 Proposed Drill Depth 04966
Original Spud 1985-01-29
Completed 1985-02-02
Reached Total Depth 1985-02-02
CO 1985-03-01 54 TITAN ENERGY CORP GeoDate 12/18/84
Completion Report Received 1985-03-05
CO 1989-10-27 54 TITAN ENERGY CORP GeoDate 10/27/89
Unknown 1989-10-27 Issued Date 10/27/89 Expired Date 10/27/90 Proposed Purpose OG Was Plug Supervised Who Superivsed Plug and Abandon Date
CO 1990-11-23 54 TITAN ENERGY CORP GeoDate 11/23/90
Unknown 1990-11-23 Issued Date 11/23/90 Expired Date 11/23/91 Proposed Purpose OG Was Plug Supervised Who Superivsed Plug and Abandon Date
Construction Permit Expires 1991-11-23
Change of Owner 1998-01-26 Operator changed from 54, TITAN ENERGY CORP to 1333, BARR ROBT/dba BIG SKY PET
Record Last Modified 2013-10-03

For data sources see[2]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
N2 0 180 Mscf 0
H2O 0 70820 Gal 70000
ACID 0 500 Gal 0 FRAC;H2O,SAND,N2

For data sources see[3]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1985 TITAN ENERGY CORP 3396.00 50.00 302
1986 TITAN ENERGY CORP 746.00 0.00 365
1987 TITAN ENERGY CORP 240.00 0.00 365
1988 TITAN ENERGY CORP 303.00 0.00 365
1989 TITAN ENERGY CORP 443.00 45.00 365
1990 TITAN ENERGY CORP 409.00 0.00 365
1991 TITAN ENERGY CORP 263.00 0.00 365
1993 TITAN ENERGY CORP 0.00 0.00 365
1994 TITAN ENERGY CORP 0.00 0.00 365
1997 TITAN ENERGY CORP 0.00 0.00 245
2013 BIG SKY ENERGY INC 0.00 0.00 365
2014 BIG SKY ENERGY INC 0.00 0.00 365
2016 BIG SKY ENERGY INC 0.00 0.00 0
2017 BIG SKY ENERGY INC 0.00 0.00 0

For data sources see[4] [5]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1985 TITAN ENERGY CORP Brine 0 302
1986 TITAN ENERGY CORP Brine 0 365
1987 TITAN ENERGY CORP Brine 0 365
1988 TITAN ENERGY CORP Brine 0 365
1989 TITAN ENERGY CORP Brine 0 365
1990 TITAN ENERGY CORP Brine 0 365
1991 TITAN ENERGY CORP Brine 0 365
1993 TITAN ENERGY CORP Brine 0 365
1994 TITAN ENERGY CORP Brine 0 365
1997 TITAN ENERGY CORP Brine 245
2013 BIG SKY ENERGY INC Brine 0 365
2014 BIG SKY ENERGY INC Brine 0 365
2016 BIG SKY ENERGY INC Brine 0 0
2017 BIG SKY ENERGY INC Brine 0 0

For data sources see[6] [7]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1584286771 2018-3-22 0:00: PW No Violations
-409280308 2016-4-11 0:00: PW No Violations
-582684989 2012-5-2 0:00:0 PW No Violations
-791927111 2019-1-30 0:00: PW No Violations 0.50
0409280308 2016-04-11 Production Wells No Violations I was on location in reference to compliance notice 1337608762. My inspection found the well to be equipped with a plunger lift unit. The annulus valve is open. The valves on the wellhead leading to the flow line are closed. There is a domestic supply plumbed into the 4.5 casing. There are 2 risers plumbed up where the separator used to be placed. The tank battery contains a 30 BBL production tank. The tank battery is over grown with trees and brush. A dike needs built around the tank battery. There is no identification on the well or the tank battery. There has been no reported production since 1997. The company has yet to comply with the issues addressed in the previous compliance notice.
0582684989 2012-05-02 Production Wells No Violations FOLLOW UP TO NOV # 1337608762 My inspection of the well site was conducted in response to a landowner complaint. According to the landowner, the current well owner has made no attempt to produce the well. The owner acquired the well in 1998 and has not reported production since.

The well was found shut-in and flow lines were disconnected. The well was equipped with a plunger lift pump unit. The tank battery contained a 30 barrel tank. There was no other surface equipment present.

Plug or produce the well or apply for temporary inactive status.

Post complete identification at the wellhead.

Failure to comply may result in forfeiture of bond.

0791927111 2019-01-30 Production Wells No Violations I conducted a compliance notice follow-up for compliance notice 1337608762, regarding installation of identification and to plug the well. At the time of this inspection, no identification has been posted at the well location and the well has not been plugged. The well was equipped with a plunger lift assembly and not in production. The 2 inch flow line has been disconnected from the well. The tank battery consisted of a 30 BBL tank. No dike was present around the tank. No other production equipment was associated with this well.
1337608762 2012-05-02 Production Wells Violations Noted My inspection of the well site was conducted in response to a landowner complaint. According to the landowner, the current well owner has made no attempt to produce the well. The owner acquired the well in 1998 and has not reported production since.

The well was found shut-in and flow lines were disconnected. The well was equipped with a plunger lift pump unit. The tank battery contained a 30 barrel tank. There was no other surface equipment present.

Plug or produce the well or apply for temporary inactive status.

Post complete identification at the wellhead.

Failure to comply may result in forfeiture of bond.

1441135646 2015-08-10 Production Wells No Violations I was on location for a follow-


Follow-up inspections will be conducted. Photos were taken and available upon request.

1584286771 2018-03-22 Production Wells No Violations I conducted a compliance notice follow-up for compliance notice 1337608762. The well was equipped with a plunger lift assembly and the annulus valve was closed. The 2 inch flow line has been disconnected from the well. The tank battery consisted of a 30 BBL tank. No other production equipment was associated with this well. There was no signage located at the well or tank. The lease access was not stable and no dike was present around the tank.
1898424316 2017-01-18 Production Wells No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1337608762 US-OH-109730 2012-05-21 Failure to legibly identify well
1337608762 US-OH-109731 2012-05-21 Nonproduction; well shall be plugged or placed in temporary inactive status

For data sources see[8]