If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-151-25870 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.81,"lon":-81.11,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Stark | |
Municipality: Paris Township | |
Operator Name: BOCOR HOLDINGS, LLC | |
Well Pad ID: | |
Farm/Lease Name: AELING | |
License Status: Producing | |
License Date: 2014-07-22 | |
Spud Date: 2014-08-06 | |
Spud Drilling Contractor: POULSON DRILLING | |
Final Drill Date: 2014-08-12 | |
Well Total Depth: 5457.00 ft | |
Configuration: Vertical | |
Latitude: 40.810000 | |
Longitude: -81.110000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2014-07-22 | Proposed Formations:CLINTON, Issued Date:7/22/2014, Expired Date:7/21/2016 12:00:00 PM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:POOL |
Reached Total Depth | 2014-08-12 | |
Completion Report Received | 2014-11-14 | |
Construction Permit Expires | 2016-07-21 | |
Record Last Modified | 2017-02-10 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2014-11-14 | 5252 | 5323 | 26 |
5252 | 5323 | 26 | |
5252 | 5323 | 26 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
2014-09-15 | H2O | 0 | 91565 Gal | 50290 | Universal Well Services Inc. | The frac job had to be scaled back during pumping due to a Universal well truck plugging off with sand. A small fire that was immediately extinguished caused the flush stage to be shut down early. The fire occurred on a turbo charger of a pumping truck when a small amount of oil landed on it and ignited burning out almost immediately. |
H2O | 0 | 156500 Gal | 535000 | Universal Well Services Inc. |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
0 | 0 | 0 | ||
2014 | BOCOR HOLDINGS, LLC | 0.00 | 502.00 | 85 |
2015 | BOCOR HOLDINGS, LLC | 3008.00 | 2264.00 | 354 |
2016 | BOCOR HOLDINGS, LLC | 229.00 | 1083.00 | 365 |
2017 | BOCOR HOLDINGS, LLC | 0.00 | 828.00 | 365 |
2018 | BOCOR HOLDINGS, LLC | 6620.00 | 620.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2014 | BOCOR HOLDINGS, LLC | Brine | 815 | 85 |
2015 | BOCOR HOLDINGS, LLC | Brine | 1071 | 354 |
2016 | BOCOR HOLDINGS, LLC | Brine | 535 | 365 |
2017 | BOCOR HOLDINGS, LLC | Brine | 425 | 365 |
2018 | BOCOR HOLDINGS, LLC | Brine | 311 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1042756894 | 2014-12-11 0:00 | PL | No Violations | 2.00 |
-1972220873 | 2015-6-19 0:00: | PL | No Violations | 1.50 |
-290173433 | 2014-9-15 0:00: | CT | No Violations | 4.00 |
0119715220 | 2014-07-30 | Administrative Inspection | No Violations | I was contacted by Bocor and informed that construction on this location will begin today and that likely Poulson Drilling will be moving onto location 8/3/14 or 8/4/14 of next week. |
0290173433 | 2014-09-15 | Completion Testing | No Violations | I was on location to witness the hydraulic fracturing of this well. Universal well services was on location and pumped the job through perforations from 5252 to 5323 using 500 gallons of 15% acid and 50290 pounds of sand as a propant. Breakdown was achieved at 1061psi and the well was treated at 43.2bbls per min at 2296psi. The initial shut in pressure was 1252psi and 5 minute shut in pressure of 1157psi. The frac job had to be scaled back during pumping due to a Universal well truck plugging off with sand. A small fire that was immediately extinguished caused the flush stage to be shut down early. A total of 91565 gallons of total slurry were pumped in the job. There are no violations at this time. |
0801296725 | 2014-08-12 | Casing String Witnessed | No Violations | I was on location to witness the cementing of the 4.5 diameter 10.5 lb/ft production casing. Poulson drilled a 7.875 diameter hole to 5452. The rig installed the 4.5 diameter casing to 5401 with 5 centralizers. Universal pumped 110sks of unitropic 10-4-2 cement and displaced it with 86bbls of freshwater. The plug was landed and pressured up to 1500psi and held for 5 minutes. The floats held and Poulson will begin rigging down and moving to a location in Summit County. |
0957312506 | 2014-08-08 | Casing String Witnessed | No Violations | I was on location to witness the cementing of the 8.625 diameter 20 lb/ft limited service surface casing installed to 728. The Poulson rig drilled an 11 diameter hole to 743 and installed the casing with 2 centralizers. Universal pumped 250sks of Class A 3% CaCl cement and displaced it with 46bbls of fresh water. 18bbls of cement were returned to surface. There are no violations at this time. |
1042756894 | 2014-12-11 | Preliminary Restoration | No Violations | I was on location to check the status of restoration for this well. The graveled lease road leads up to a pumpjack well with a dike. The tank battery is contained within a dike and contains a 210bbl production tank, two 50bbl brine tanks, ID sign and horizontal separator. The location has been seeded and vegetation has been established. The wellhead does not contain the necessary annular pressure gauge and pop off. I have contacted Bocor and informed them that these will need to be installed. I will pass preliminary restoration when the needed gauges and pop off are installed. |
119715220 | 2014-7-30 0:00: | AM | No Violations | 0.50 |
1407344013 | 2014-08-06 | Casing String Witnessed | No Violations | I was on location to witness the cementing of the conductor casing for this well. Poulson Drilling drilled a 14.75 diameter hole to 121. Drift was 93. The rig installed 116 of 32 lb/ft 11.75 OD limited service casing. Universal pumped 90sks of Class A 3%CaCl cement and displaced it with 13bbls of freshwater. One bbl of cement was pumped to surface, the rig is going to top off the conductor hole with Quikrete before drilling ahead and will use excess cement from the 8.625 OD surface cement job to fill the cellar with more cement. There are no violations at this time. |
1883275526 | 2014-08-07 | Drill / Deepen / Reopen | No Violations | I was on location to check the status of Poulson drilling. The rig was currently running at survey at 588 and a 2 degree deviation. The rig is going to drill their 11 hole to 700 before installing their 8.625 OD surface casing through the Big Injun. They expect to be drilling for 3 more hours before coming out of the hole and installing and cementing the casing. |
1972220873 | 2015-06-19 | Preliminary Restoration | No Violations | I was on location to check the status of restoration for this well. The graveled lease road leads up to a pumpjack well with a dike. The electric driven pumpjack is in good condition and contains all required gauges. The tank battery is contained within a dike and contains a 210bbl production tank, two 50bbl brine tanks, property identification and horizontal separator with house gas connection. The location has been seeded and vegetation has been established. The tank battery, wellhead and roadway all conform to spacing requirements. At this time preliminary restoration has been passed. |
801296725 | 2014-8-12 0:00: | CS | No Violations | 4.00 |
957312506 | 2014-8-8 0:00:0 | CS | No Violations | 4.00 |
For data sources see[9]