34-139-20097

Well Details

Well ID: 34-139-20097
Loading map...
Country: United States
State: Ohio
County: Richland
Municipality: Monroe Township
Operator Name: COLUMBIA GAS TRANSMISSION LLC
Well Pad ID:
Farm/Lease Name: FRONTZ CL
License Status: Storage Well
License Date:
Spud Date: 1949-03-17
Spud Drilling Contractor:
Final Drill Date: 1949-04-26
Well Total Depth: 2490.00 ft
Configuration: Vertical
Latitude: 40.710000
Longitude: -82.340000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1949-03-17 GL=1072.1
Completed 1949-04-26 GL=1072.1
Reached Total Depth 1949-04-26 GL=1072.1
Record Last Modified 2009-12-11 GL=1072.1

For data sources see[2]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1143869040 2014-4-11 0:00: SO No Violations 0.50
-129618965 2015-1-20 0:00: SO No Violations 0.50
-1790571757 2016-12-7 0:00: SO No Violations 0.50
-1816449614 2019-3-15 0:00: SO No Violations
0098215986 2017-11-06 Storage Well No Violations ID is posted and the location is maintained. There is a 5 barrel tank connected to the valve on the surface-production annulus. The annulus is shut in. The well is equipped with a separator and house gas tap at the pipeline tie in.
0129618965 2015-01-20 Storage Well No Violations ID posted. Gas was heard bubbling on the 2 inch valve on the backside of the production string. Gas was observed leaking from the fitting. The well tender was contacted and he advised that he contacted Columbias well service department to assess the well. I will follow up with Terry VanSickle of Columbia Gas following his evaluation of the well.
0554885775 2018-11-19 Storage Well No Violations ID is posted and the location is maintained. The annulus is shut in. The well is equipped with a separator, 5 barrel tank and house gas connection at the pipeline tie in. Electronic pressure monitoring has been installed at the well.
1143869040 2014-04-11 Storage Well No Violations ID posted, location maintained.
1790571757 2016-12-07 Storage Well No Violations ID is posted and the location is maintained. The well is equipped with a separator. There is a 5 barrel tank connected to the valve on the surface annulus. The annulus is shut in.
1816449614 2019-03-15 Storage Well No Violations Identification is posted. Wellhead has electronic measuring equipment installed. Small plastic storage tank connected to annulus of well. Well is connected to a drip. Rural domestic meter tap at wellsite.
505659198 2020-5-29 0:00: SO No Violations
554885775 2018-11-19 0:00 SO No Violations
98215986 2017-11-6 0:00: SO No Violations