34-133-24413

Well Details

Well ID: 34-133-24413
Loading map...
Country: United States
State: Ohio
County: Portage
Municipality: Suffield Township
Operator Name: SOUND ENERGY CO INC
Well Pad ID:
Farm/Lease Name: EVANS UNIT
License Status: Producing
License Date: 2011-06-03
Spud Date: 2011-06-24
Spud Drilling Contractor: ADVENT DRLG
Final Drill Date: 2011-07-06
Well Total Depth: 7131.00 ft
Configuration: Vertical
Latitude: 41.040000
Longitude: -81.310000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2011-06-03 Proposed Formations:TRENTON THRU KNOX, Issued Date:6/3/2011, Expired Date:6/2/2013 12:00:00 PM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:EDPW
Reached Total Depth 2011-07-06
Completion Report Received 2011-08-30
Construction Permit Expires 2012-06-02
Change of Owner 2015-05-12 Operator changed from 7626, M & M ROYALTY LTD to 4327, SOUND ENERGY CO INC
Record Last Modified 2017-10-24

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2011-11-30 6972 7024 42
6972 7024 42
6972 7024 42

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2011-08-11 H2O 0 80900 Gal 60000 Universal Well Services Inc.

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2011 M & M ROYALTY LTD 1671.00 4572.00 365
2012 M & M ROYALTY LTD 10951.00 6021.00 366
2013 M & M ROYALTY LTD 7681.00 2311.00 365
2014 M & M ROYALTY LTD 4723.00 1753.00 365
2015 SOUND ENERGY CO INC 1620.00 773.00 305
2016 SOUND ENERGY CO INC 2208.00 1042.00 365
2017 SOUND ENERGY CO INC 2087.00 841.00 365
2018 SOUND ENERGY CO INC 1704.00 769.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2011 M & M ROYALTY LTD Brine 788 365
2012 M & M ROYALTY LTD Brine 1869 366
2013 M & M ROYALTY LTD Brine 1849 365
2014 M & M ROYALTY LTD Brine 943 365
2015 SOUND ENERGY CO INC Brine 911 305
2016 SOUND ENERGY CO INC Brine 699 365
2017 SOUND ENERGY CO INC Brine 581 365
2018 SOUND ENERGY CO INC Brine 420 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1233776028 2011-8-2 0:00:0 PL No Violations
-1294836953 2011-6-30 0:00: DD No Violations
-245715961 2011-7-7 0:00:0 DD No Violations
-266312334 2011-11-15 0:00 PW No Violations
-594430397 2011-8-11 0:00: CT No Violations
0037652284 2011-07-07 Drill / Deepen / Reopen No Violations I performed a rig inspection on Advent rig 1. The rig crew were running into the hole with 4 1/2 csing. This inspection satisfies 1501:9-9-03. There were no violations at this time.
0245715961 2011-07-07 Drill / Deepen / Reopen No Violations I witnessed the cementing of the 4 1/2 casing. There were no violations at this time.
0266312334 2011-11-15 Production Wells No Violations I received a call from Mrs. Tracy Dardenner, 2202 Palm Road (330-524-1572) about a vibration at the pumping unit. She claims the vibration has been shaking her house. This complaint is a continuation of an anonymous complaint about the noise at the pumping unit received on 11-1-11. I told Mrs. Dardenner that I will check the vibration out tomorrow. I called Mike Wiensz (330-324-19570) and he stated that they will install car mufflers on the pumping unit next week. I called Mrs. Dardenner back to inform her of the muffler installation. I called Gene Chini to give him an update on this complaint. This complaint continues.
0278399772 2011-07-06 Drill / Deepen / Reopen No Violations I performed a rig inspection on Advent rig 1. The drilling depth was 6985 and drilling in the Knox. A mud logger was on the drilling location. The rig was drilling on fluid. This inspection satisfies 1501:9-9-03. There were no violations at this time.
0583860603 2011-07-19 UrbanPreliminary Restoration No Violations The drilling rig is gone and the debris has been removed. The fliud level in the drilling pits are down 2 feet from the top. There were no violations at this time.
0594430397 2011-08-11 Completion Testing No Violations I witnessed the fracing by Universal. The formation broke at 2350psi. Sixty balls were dropped. There were 42 holes. The well was sand fracd. ISIP was 2900psi. Five minute reading was 2770psi. Ten minute reading was 2694psi. There were no violations at this time.
1233776028 2011-08-02 Preliminary Restoration No Violations The drilling pits are closed. The drilling rig is gone. There were no violations at this time.
1294836953 2011-06-30 Drill / Deepen / Reopen No Violations I performed a rig inspection on Advent rig #1. The drilling depth was 6023 and drilling on air. The mud logger is on the drilling location. This inspection satisfies 1501:9-9-03. There were no violations at this time.
1309527122 2011-06-29 Drill / Deepen / Reopen No Violations I performed a rig inspection on Advent rig #1. The drilling depth was 4984 which is in the Queenston zone. The rig was drilling on air. This inspection satisfies 1501:9-9-03. There were no violations at this time.
1309973008 2011-07-05 Drill / Deepen / Reopen No Violations I performed a rig inspection on Advent rig #1. The drilling depth was 6830 and drilling on fluid. There was a mud logger on the drilling location. This inspection satisfies 1501:9-9-03. There were no violations at this time.
1314811144 2011-08-31 UrbanPreliminary Restoration No Violations The top soil has been spread on the drilling site. There were no violations at this time.
1315937809 2011-09-13 Preliminary Restoration No Violations The topsoil has been spread over the location and the site rough graded. There were no violations at this time.
1321532190 2011-11-16 Production Wells No Violations I performed a complaint inspection on this well. It was noted that Mrs. Tracy Dardenner of 2202 Palm Road feels a vibration at her house. I spent 5 minutes across from the 2202 Palm Road and found no noise or vibration. I walked south approximately 100 feet and heard a mild sound coming from the motor of well pumping unit. The well this pumping unit is on is 600 - 700 feet west of Mrs. Dardenners house. I inspected the well. A chain link fence with ID sign was posted. The glass pack motor mufflers were installed. I called Mike Wiensz (330-324-19570) about the mufflers. Mike stated that they are going to install car mufflers on this well next week. I called Mrs. Dardenner back and imformed her that I did not hear any noise/vibration across from her house, but that I could barely hear the pump jack motor 100 feet to the south of her house. I also informed her that the well owner/operator will install two car mufflers on the pumping unit next week. Once the new mufflers are installed the operator and I will perform a decibel tests on this well. She says she will wait to see if that takes care of her problem. This complaint continues.
1321994915 2011-11-22 Surface Facility Construction No Violations I inspected this well pumping unit. It had the car mufflers installed and the pumping unit was running. The unit was as quite as a electric pumping unit. I called Tracy Dardenner (330-524-1572) of 2202 Palm Road to let her know that the mufflers had been installed but I had not performed a decibel test yet. She stated that she could not hear the noise during the day but she could still hear some noise at night. She told me she would try and live with it. I called Gene Chini and gave him the update on this complaint. This complaint is resolved.
278399772 2011-7-6 0:00:0 DD No Violations
37652284 2011-7-7 0:00:0 DD No Violations
574553006 2019-5-31 0:00: UL No Violations 0.70
583860603 2011-7-19 0:00: UL No Violations

For data sources see[9]

References