34-133-23954

Well Details

Well ID: 34-133-23954
Loading map...
Country: United States
State: Ohio
County: Portage
Municipality: Deerfield Township
Operator Name: EVERFLOW EASTERN PARTNERS LP
Well Pad ID:
Farm/Lease Name: BERLIN RESERVOIR
License Status: Producing
License Date: 1993-08-24
Spud Date: 1994-07-15
Spud Drilling Contractor: IPSCO
Final Drill Date: 1994-07-21
Well Total Depth: 5614.00 ft
Configuration: Directional
Latitude: 40.990000
Longitude: -81.010000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1993-04-20 198 VIKING RESOURCES CORP GeoDate 4/20/93
Oil and Gas 1993-04-20 Issued Date 4/20/93 Expired Date 4/20/94 Acres 0040000 Tool Type RTAF Proposed Formation CLINTON Proposed Depth Proposed Drill Depth
CO 1993-08-24 198 VIKING RESOURCES CORP GeoDate 8/24/93
Oil and Gas 1993-08-24 Issued Date 8/24/93 Expired Date 8/24/94 Acres 0040000 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 05614 Proposed Drill Depth 05614
Original Spud 1994-07-14 CHG. LOC./XY 10-8-94
Completed 1994-07-21 CHG. LOC./XY 10-8-94
Reached Total Depth 1994-07-21 CHG. LOC./XY 10-8-94
Construction Permit Expires 1994-08-24 CHG. LOC./XY 10-8-94
CO 1994-09-14 84 EVERFLOW EASTERN PTNS L P GeoDate 8/24/93
Completion Report Received 1995-03-13 CHG. LOC./XY 10-8-94
Record Last Modified 2017-02-15 CHG. LOC./XY 10-8-94

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 5341 5478 0
5341 5478 0
2006-09-11 5373 5478 76
5373 5478 76
5341 5478 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 102700 Gal 70500 FRAC W/102,700 GAL WATER & 705 SX

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1995 EVERFLOW EASTERN PARTNERS LP 16206.00 1307.00 365
1996 EVERFLOW EASTERN PARTNERS LP 10214.00 545.00 365
1997 EVERFLOW EASTERN PARTNERS LP 12023.00 705.00 365
1998 EVERFLOW EASTERN PARTNERS LP 7688.00 413.00 365
1999 EVERFLOW EASTERN PARTNERS LP 19037.00 857.00 365
2000 EVERFLOW EASTERN PARTNERS LP 26043.00 927.00 365
2001 EVERFLOW EASTERN PARTNERS LP 10136.00 223.00 365
2002 EVERFLOW EASTERN PARTNERS LP 7561.00 343.00 365
2003 EVERFLOW EASTERN PARTNERS LP 9247.00 253.00 365
2004 EVERFLOW EASTERN PARTNERS LP 7487.00 173.00 365
2005 EVERFLOW EASTERN PARTNERS LP 7620.00 253.00 365
2006 EVERFLOW EASTERN PARTNERS LP 7135.00 256.00 365
2007 EVERFLOW EASTERN PARTNERS LP 3305.00 107.00 365
2008 EVERFLOW EASTERN PARTNERS LP 6050.00 114.00 365
2009 EVERFLOW EASTERN PARTNERS LP 4090.00 63.00 365
2010 EVERFLOW EASTERN PARTNERS LP 5302.00 183.00 365
2011 EVERFLOW EASTERN PARTNERS LP 6408.00 181.00 365
2012 EVERFLOW EASTERN PARTNERS LP 5404.00 181.00 366
2013 EVERFLOW EASTERN PARTNERS LP 4538.00 119.00 365
2014 EVERFLOW EASTERN PARTNERS LP 4565.00 167.00 365
2015 EVERFLOW EASTERN PARTNERS LP 3086.00 60.00 365
2016 EVERFLOW EASTERN PARTNERS LP 3003.00 62.00 365
2017 EVERFLOW EASTERN PARTNERS LP 4824.00 133.00 365
2018 EVERFLOW EASTERN PARTNERS LP 4696.00 169.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1995 EVERFLOW EASTERN PARTNERS LP Brine 109 365
1996 EVERFLOW EASTERN PARTNERS LP Brine 23 365
1997 EVERFLOW EASTERN PARTNERS LP Brine 0 365
1998 EVERFLOW EASTERN PARTNERS LP Brine 0 365
1999 EVERFLOW EASTERN PARTNERS LP Brine 23 365
2000 EVERFLOW EASTERN PARTNERS LP Brine 80 365
2001 EVERFLOW EASTERN PARTNERS LP Brine 0 365
2002 EVERFLOW EASTERN PARTNERS LP Brine 0 365
2003 EVERFLOW EASTERN PARTNERS LP Brine 0 365
2004 EVERFLOW EASTERN PARTNERS LP Brine 20 365
2005 EVERFLOW EASTERN PARTNERS LP Brine 0 365
2006 EVERFLOW EASTERN PARTNERS LP Brine 0 365
2007 EVERFLOW EASTERN PARTNERS LP Brine 10 365
2008 EVERFLOW EASTERN PARTNERS LP Brine 0 365
2009 EVERFLOW EASTERN PARTNERS LP Brine 16 365
2010 EVERFLOW EASTERN PARTNERS LP Brine 19 365
2011 EVERFLOW EASTERN PARTNERS LP Brine 0 365
2012 EVERFLOW EASTERN PARTNERS LP Brine 0 366
2013 EVERFLOW EASTERN PARTNERS LP Brine 27 365
2014 EVERFLOW EASTERN PARTNERS LP Brine 18 365
2015 EVERFLOW EASTERN PARTNERS LP Brine 0 365
2016 EVERFLOW EASTERN PARTNERS LP Brine 26 365
2017 EVERFLOW EASTERN PARTNERS LP Brine 0 365
2018 EVERFLOW EASTERN PARTNERS LP Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1528151554 2010-7-7 0:00:0 PW No Violations
-710970352 2010-8-17 0:00: PW No Violations
0710970352 2010-08-17 Production Wells No Violations A second status check inspection requested by the Bureau of Land Management (BLM) found no violations at this time. The area around the wellhead and inside of the security fence has been filled with crushed stone and a 2 elbow and nipple were added to the 8-5/8 wellhead. No violations at this time.
0907574813 2017-12-14 Production Wells No Violations Status check inspection of this directional Clinton Sandstone well. My inspection found the wellhead fenced and locked. The well is equipped with 1.5 tubing and operating with the aid of a plunger lift system. A gauge on the flow line indicates a pressure of 110psi and the required ID is posted on the fencing. The well produces to a diked tank battery on location and is shared by the Berlin Reservoir 24-D (PN#3955) and the J. Hawkins #1 (PN#3641). This well and the 24-D produce through a dedicated, horizontal separator and into a 210 barrel tank and a 50 barrel tank. The battery is fenced and locked and the required ID is posted on the fencing. No violations.
1528151554 2010-07-07 Production Wells No Violations Becky Metz with BLM requested this inspection. There are no violations at this time. There are several small areas (less than one square foot each) inside of the tank battery dike where old oil/parafin have stained the stone pad. These areas are under drain valves and near the small valves used to determine the oil/water transition during brine transfer. The stained areas are the result of normal operations.
907574813 2017-12-14 0:00 PW No Violations 0.40
iANGE00155 1998-05-07 Preliminary Restoration No Violations
iANGE001557 1998-5-7 0:00:0 PL No Violations

For data sources see[9]