34-073-60116

Well Details

Well ID: 34-073-60116
Loading map...
Country: United States
State: Ohio
County: Hocking
Municipality: Benton Township
Operator Name: COLUMBIA GAS TRANSMISSION LLC
Well Pad ID:
Farm/Lease Name: MAHLON PAXTON ET UX
License Status: Final Restoration
License Date: 2010-10-13
Spud Date:
Spud Drilling Contractor:
Final Drill Date: 1918-06-18
Well Total Depth: 2133.00 ft
Configuration: Vertical
Latitude: 39.440000
Longitude: -82.610000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Completed 1918-06-18
Reached Total Depth 1918-06-18
APP 2010-10-13 Proposed Formations:CLINTON, Issued Date:10/13/2010, Expired Date:10/12/2012 12:00:00 PM, Drilling unit acres:298, Proposed Well Type:SO, Proposed Well Class:
Plugged/Abandoned 2010-12-10
Construction Permit Expires 2012-10-12
Record Last Modified 2013-03-14

For data sources see[2]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1420638051 2010-12-10 0:00 PB No Violations 4.00
-2012626012 2010-11-22 0:00 PB No Violations
-584346128 2010-11-23 0:00 PB No Violations 3.00
0584346128 2010-11-23 Plug / Plug Back No Violations Witnessed TIH with perforation gun and shot 5 holes in 5.5 casing at 1430 (ground level) or 1438 (derrick floor). Set 5.5 cement retainer at 1422 (ground level). Hauled in 2.38 drill pipe and TIH with stinger. Tomorrow, company will mix and pump cement to retainer; stab in stinger and squeeze 4bbls of cement behind 5.5 casing to approx 1000; pull out of retainer and spot a 316 plug (inside casing).
0606314669 2011-09-15 Final Restoration No Violations Restoration meets 1509.072 requirements.
1075911770 2010-11-17 Plug / Plug Back No Violations Checked on status of plugging and abandonment. No activity at time of inspection. A Baker Atlas Digital Magnelog (DMAG) will be ran tomorrow. GPS reading obtained from this inspection and confirmed well location.
1420638051 2010-12-10 Plug / Plug Back No Violations Witnessed plug job.
1463263309 2010-12-01 Plug / Plug Back No Violations Checked on status of plugging and abandonment. Mr. Steve Hampshire, a Storage Well Tech with Columbia Gas Transmission, stated cement top inside 5.5 casing at 1116. The 5.5 casing had been cut at 1085 but pulled in two at 40. Currently, 5.5 casing is out and now at 600. A DMAG ran while inside 3.5 casing had showed no 7casing. Columbia ran a 6.5 junk mill for further reassurance. Obstruction noted and casing verified. A 7 spear and 7 cutter will be utilized for casing retrieval. Records indicate no cement or mud behind this casing.
1545616203 2010-12-08 Plug / Plug Back No Violations Checked on status of plugging.
2012626012 2010-11-22 Plug / Plug Back No Violations Witnessed 3.5 squeeze job/bottom plug on 11/22/2010. A 3.5 cement retainer was set with wireline at 2088. TBIH with stinger. Mixed and pumped 5 bbl Class A cement to stinger. Stabbed in stinger and squeezed 1.2 bbl in anchor and on backside. Stabbed out of retainer and displaced cement with 3.5 bbls of freshwater. Pulled joints to 1878 and cleared hole of excess cement. Note: On 11/19/2010, Kilbarger Rig 15 had found plug at 2080 and milled clean to bottom.
606314669 2011-9-15 0:00: FR No Violations 1.00

For data sources see[3]