X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-035-22086

Well Details

Well ID: 34-035-22086
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: BAAY OIL LLC
Well Pad ID:
Farm/Lease Name: NEGRELLI UNIT
License Status: Producing
License Date: 2008-11-25
Spud Date: 2009-01-04
Spud Drilling Contractor: WHIPSTOCK OHIO DRILLING
Final Drill Date: 2009-01-16
Well Total Depth: 3660.00 ft
Configuration: Directional
Latitude: 41.500000
Longitude: -81.420000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2008-11-25 Proposed Formations:CLINTON, Issued Date:11/25/2008, Expired Date:11/25/2009 6:00:00 AM, Drilling unit acres:22.07, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2009-01-16
Construction Permit Expires 2009-11-25
Completion Report Received 2009-12-14
Change of Owner 2016-01-29 Operator changed from 1304, SEAGULL DEVELOPMENT CORP to 8560, BAAY OIL LLC
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2010-02-09 3469 3509 25
3469 3509 25
3469 3509 25

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 63780 Gal 25000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2009 SEAGULL DEVELOPMENT CORP 26906.00 0.00 211
2010 SEAGULL DEVELOPMENT CORP 74531.00 51.00 365
2011 SEAGULL DEVELOPMENT CORP 64851.00 0.00 365
2012 SEAGULL DEVELOPMENT CORP 54022.00 44.00 366
2013 SEAGULL DEVELOPMENT CORP 46112.00 0.00 365
2014 SEAGULL DEVELOPMENT CORP 25134.00 0.00 365
2015 SEAGULL DEVELOPMENT CORP 21453.00 0.00 365
2016 BAAY OIL LLC 18517.00 0.00 365
2017 BAAY OIL LLC 16485.00 0.00 365
2018 BAAY OIL LLC 14389.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2009 SEAGULL DEVELOPMENT CORP Brine 0 211
2010 SEAGULL DEVELOPMENT CORP Brine 88 365
2011 SEAGULL DEVELOPMENT CORP Brine 53 365
2012 SEAGULL DEVELOPMENT CORP Brine 7 366
2013 SEAGULL DEVELOPMENT CORP Brine 0 365
2014 SEAGULL DEVELOPMENT CORP Brine 0 365
2015 SEAGULL DEVELOPMENT CORP Brine 0 365
2016 BAAY OIL LLC Brine 50 365
2017 BAAY OIL LLC Brine 8 365
2018 BAAY OIL LLC Brine 8 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1064679951 2018-8-7 0:00:0 UP No Violations 1.00
-1384779023 2009-1-12 0:00: DD No Violations
-1721078696 2018-1-8 0:00:0 UP No Violations 0.50
-1787595550 2017-10-11 0:00 UP No Violations 0.50
-298708911 2008-12-12 0:00 DD No Violations
-31523585 2009-7-20 0:00: PW No Violations
-801184974 2009-1-8 0:00:0 DD No Violations
-822598953 2016-2-2 0:00:0 UP No Violations 0.50
0031523585 2009-07-20 Production Wells No Violations board on board fencing up waiting on grass growth.
0182414216 2009-01-06 Drill / Deepen / Reopen No Violations surface casing cementing
0298708911 2008-12-12 Drill / Deepen / Reopen No Violations making location
0801184974 2009-01-08 Drill / Deepen / Reopen No Violations drilling at kick point 1300
0822598953 2016-02-02 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. At the time of this inspection, I observed the following: Ingress and egress from the well area is afforded by a short, dedicated lease road which enters from Chartley. A wellhead with mechanical plunger lift system is located in a board-on-board enclosure in a wooded portion of the lot. The well enclosure was locked and secure. Fittings and connections at the wellhead were secure and free from leakage. The 8.625-inch casing annulus was exposed and plumbed into the system. Areas around the wellhead consist of turf grass which was free from signs of stress or impact. The tank battery is located 50 feet east of the wellhead within the same grassy and wooded yard area. The battery is comprised of one 100-barrel, low-boy steel production tank, one 50-barrel poly brine tank. At the time of this inspection, the access gate to the battery was locked and secure. Signage was present. Fittings and connections were secure and free from signs of leakage or problems. Process safety gear and carbon filter system was present. Secondary containment was intact and dry. Tank lids were closed. The load-outs are located remotely from the battery near the road, and are plugged and locked. Evergreen screening was present surrounding the battery and is good condition. I walked the area surrounding the battery and observed normal grassy vegetation with no signs of erosional deficits or impacts associated with the production operation. I did observe the following maintenance issue: the production tank lid is missing the closure wing-nut. This needs replaced to effect a proper seal. Ive notified the well owner regaridng the misssing wing-nut.
1064679951 2018-08-07 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. I found the wellhead plunger lift and tank battery connections to be secure and free from leakage or problems. The load-lines were locked and secure. I noted that the battery enclosure gate was missing the lock and I contacted the well tender . Production reports were current. The well was in production with an active chart record. I walked and inspected the areas surrounding the well and battery and found no signs of problems.
1331646382 2012-03-06 UrbanProduction Wells No Violations My inspection found that the brine storage tank is collapsed and needs to be replaced and replumbed properly. The Pressure Differential Control regulator, which was leaking prior to this date, has been repaired.
1384779023 2009-01-12 Drill / Deepen / Reopen No Violations drilling had to set kick plug drilling off path
1402412655 2014-06-10 UrbanPreliminary Restoration No Violations I inspected this producing unit to evaluate conditions for preliminary restoration. The well was completed in 04/30/2010. Elements of the well consist of a production wellhead with standard valve assembly and mechanical plunger lift system. The wellhead is located in a closed and locked board-on-board enclosure. The 8.625-inch casing is valved to surface but is not gauged. There are no signs of leakage or problems at the wellhead. There is a domestic meter tie-in at the wellhead. The aboveground storage tank battery is located east and adjacent to the wellhead. The battery is comprised of 1 steel 100-barrel production tank, 1 50-barrel poly brine tank, and a horizontal separator. The battery is located in a separate board-on-board enclosure which is gated and locked. The load-outs are bull-plugged and locked. There is process safety equipment in use (carbon filter, low-pressure relief valve, and spark arrestor). The secondary containment at the battery appears well maintained. I did not observe any signs or evidence of leakage, spills, or problems. There is ID signage at the battery and wellhead which are legible and in good condition. The area formerly occupied by drilling equipment, including former pits, has been restored and reclaimed. There is well established grassy vegetation throughout the area. The area of the well is generally level with a slight topographic drop to the northwest. Surface draining appears to be to the northwest. There are no surface water courses evident near the site. I did not observe any signs of gully formation or washouts. Access to the unit is afforded by a dedicated gravel-paved access road located directly across from the house at 1925 Chartley . The short access road is currently in good condition and free of washout or erosional deficits. Beyond the area cleared for the wellhead and tank battery, the areas surrounding the unit are moderately wooded with single-family residential homes bordering to the north and south, and dense
1721078696 2018-01-08 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. The well and battery are located in a grassy and wooded fringe area, with suburban residential beyond. At the time of this inspection I noted the following: a well with plunger-lift system and associated tank battery in separate board-on-board enclosures which were locked and secure. The load-line valves were plugged, locked and secure. The secondary containment was intact. The production reports were current. The well was producing with an active chart record. I walked and inspected the areas surrounding the well and battery and found no indications of problems.
1787595550 2017-10-11 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. At the time of this inspection, I observed the following: The wellhead plunger lift and associated tank battery located in the back of a residential property. At the time of this inspection, I observed the following: The enclosure gates were locked. The load lines were plugged and secure. The secondary containment was intact and dry with no signs of leaks or spills. Fittings and connections at the wellhead and battery were secure and free from leakage or problems. I walked the areas surrounding the wellhead and battery, and found no signs of impact or degradation attributable to the production system. The dedicated access drive and entry were in good condition.
182414216 2009-1-6 0:00:0 DD No Violations

For data sources see[9]

References