X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-035-22062

Well Details

Well ID: 34-035-22062
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: BAAY OIL LLC
Well Pad ID:
Farm/Lease Name: DROE UNIT
License Status: Producing
License Date: 2008-07-29
Spud Date: 2008-09-08
Spud Drilling Contractor: WHIPSTOCK OHIO DRILLING
Final Drill Date: 2008-09-14
Well Total Depth: 3584.00 ft
Configuration: Vertical
Latitude: 41.520000
Longitude: -81.440000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2008-07-29 Proposed Formations:CLINTON, Issued Date:7/29/2008, Expired Date:7/29/2009 6:00:00 AM, Drilling unit acres:20.91, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2008-09-14 OPEN HOLE LOG DID NOT REACH TD; LOGGER'S TD TAKEN INSIDE 4.5" CASING
Completion Report Received 2009-02-09 OPEN HOLE LOG DID NOT REACH TD; LOGGER'S TD TAKEN INSIDE 4.5" CASING
Construction Permit Expires 2009-07-29 OPEN HOLE LOG DID NOT REACH TD; LOGGER'S TD TAKEN INSIDE 4.5" CASING
Change of Owner 2016-01-29 Operator changed from 1304, SEAGULL DEVELOPMENT CORP to 8560, BAAY OIL LLC
Record Last Modified 2017-02-15 OPEN HOLE LOG DID NOT REACH TD; LOGGER'S TD TAKEN INSIDE 4.5" CASING

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2009-03-24 3397 3465 27
3397 3465 27
3397 3465 27

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 64692 Gal 25000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2009 SEAGULL DEVELOPMENT CORP 107202.00 685.00 360
2010 SEAGULL DEVELOPMENT CORP 78507.00 315.00 365
2011 SEAGULL DEVELOPMENT CORP 51060.00 173.00 365
2012 SEAGULL DEVELOPMENT CORP 19338.00 58.00 366
2013 SEAGULL DEVELOPMENT CORP 14905.00 62.00 365
2014 SEAGULL DEVELOPMENT CORP 9469.00 94.00 365
2015 SEAGULL DEVELOPMENT CORP 3331.00 43.00 365
2016 BAAY OIL LLC 1283.00 39.00 365
2017 BAAY OIL LLC 1511.00 0.00 365
2018 BAAY OIL LLC 615.00 44.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2009 SEAGULL DEVELOPMENT CORP Brine 0 360
2010 SEAGULL DEVELOPMENT CORP Brine 326 365
2011 SEAGULL DEVELOPMENT CORP Brine 420 365
2012 SEAGULL DEVELOPMENT CORP Brine 358 366
2013 SEAGULL DEVELOPMENT CORP Brine 174 365
2014 SEAGULL DEVELOPMENT CORP Brine 295 365
2015 SEAGULL DEVELOPMENT CORP Brine 194 365
2016 BAAY OIL LLC Brine 194 365
2017 BAAY OIL LLC Brine 240 365
2018 BAAY OIL LLC Brine 115 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1629779645 2016-2-4 0:00:0 UP No Violations 0.50
-1874728783 2009-4-27 0:00: DD No Violations
-1971173597 2017-11-22 0:00 UP No Violations 0.50
-974792379 2008-9-10 0:00: DD No Violations
0190829819 2008-09-15 Drill / Deepen / Reopen No Violations setting 4.5
0218312556 2008-09-08 Drill / Deepen / Reopen No Violations Location made ready for rig
0494295515 2012-09-28 UrbanProduction Wells No Violations The tank battery (TB) is enclosed within an 8-foot, wood slat style enclosure. The gate is locked. The TB is comprised of one, 210-barrel (BBL) production tank, one, 10 BBL poly brine tank, a mechanical separator and associated valves. The mechanicals are in good condition and the TB dike is present and intact. Tank spacing is good. The wellhead is enclosed within a 6-foot, wood slat enclosure. The wellhead is fitted with a plunger-lift system. I observed gas leaking or venting from the wellhead. I advised Cuyahoga County Inspector Ray Wallace about leaking gas and he indicated that he would follow up with the well owner.
0974792379 2008-09-10 Drill / Deepen / Reopen No Violations setting surface
1097012384 2008-09-09 Drill / Deepen / Reopen No Violations cementing conductor
1168794053 2008-09-08 Drill / Deepen / Reopen No Violations location made
1231943501 2008-09-10 Drill / Deepen / Reopen No Violations called Mr Persianos he said they are on his peroperty with water lines I advised him that company will remove lines As soon as posible. Called company talked with Lynn Stazy he will call mr Persianos an rig crew to get water lines removed.
1233078982 2009-01-07 Drill / Deepen / Reopen No Violations area graded not seeded to cold
1331659339 2012-03-06 UrbanProduction Wells No Violations An identification needs to be posted at the well head. The trash in the tank battery needs to be removed. Plugs need to be installed in both ends of tank battery drain. This drain should only be opened/used when a company representative is present.
1425058092 2015-02-27 UrbanProduction Wells No Violations I inspected this well as part of routine inspection activity. The wellhead and battery are located behind a single-family residence at the referenced address. Access to the well is via the shared residential driveway. The wellhead plunger lift and battery are in separate board-on-board enclosures which are locked. Fittings and connections are secure and free from signs of leakage or problems. The load-outs are secure, plugged, and locked. Process safety gear is present. Signage is in place and current. At the time of this inspection there are 15 to 20 inches of snow cover in the area which obscures some surficial elements from observation.
1629779645 2016-02-04 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. At the time of this inspection, I observed the following: Ingress and egress to and from the well area is afforded by the shared house driveway with short, unpaved section at the battery. A wellhead with mechanical plunger lift system is located in a board-on-board enclosure in the otherwise open portion of the back yard. The well enclosure was locked and secure. Fittings and connections at the wellhead were secure and free from leakage. The 8.625-inch casing annulus was exposed and fitted with pressure-relief fitting. Areas around the wellhead consist of turf grass which was free from signs of stress or impact. The tank battery is located 50 feet south of the wellhead within the same grassy and wooded yard area. The battery is comprised of one 100-barrel, steel production tank, one 50-barrel poly brine tank. At the time of this inspection, the access gate to the battery was locked and secure. Signage was present. Fittings and connections were secure and free from signs of leakage or problems. Process safety gear and carbon filter system was present. Secondary containment was intact and dry. Tank lids were closed. The load-outs are located remotely from the battery near the road, and were plugged and locked. Screening was present surrounding the battery and wellhead and comprised of deciduous shrubs that were bare owing to the season, but in otherwise good condition. I walked the area surrounding the battery and observed normal grassy vegetation with no signs of erosional deficits or impacts associated with the production operation. I did observe the following maintenance issue: the production tank lid is missing the closure wing-nut. This needs replaced to effect a proper seal. I notified the owner about the need to replace the missing wing nut.
1795464661 2010-08-04 Preliminary Restoration No Violations
1874728783 2009-04-27 Drill / Deepen / Reopen No Violations working on restoration
190829819 2008-9-15 0:00: DD No Violations
1971173597 2017-11-22 UrbanProduction Wells No Violations I inspected this well as part of routine inspection activity. The well and battery are located at the back portion of a single-family residence. At the time of this inspection, I found the following: a wellhead plunger-lift unit and associated battery, accessed via the shared driveway, with a short, gravel-paved extension to the battery. The fittings and connections were secure and free from leakage or problems. Fittings and connections at the battery were secure. The load-lines were plugged and locked. ID signage was present and current. The secondary containment was intact with no signs of leakage, spills, or problems. The well was in active production. The chart recorder was active. Production reports were current. Bonding and insurance was in place and current. I noted that the board-on-board enclosure at the wellhead was dismantled. I contacted Brooks Yarborough with Baay Oil and he reported that service work on this well was pending and the enclosure would be replaced when that was completed.
218312556 2008-9-8 0:00:0 DD No Violations
494295515 2012-9-28 0:00: UP No Violations

For data sources see[9]

References