34-029-62732

Well Details

Well ID: 34-029-62732
Loading map...
Country: United States
State: Ohio
County: Columbiana
Municipality: Salem Township
Operator Name: COLUMBIA GAS TRANSMISSION LLC
Well Pad ID:
Farm/Lease Name: BAKER MYRTLE
License Status: Storage Well
License Date: 1994-04-21
Spud Date: 1900-01-01
Spud Drilling Contractor:
Final Drill Date:
Well Total Depth:
Configuration: Vertical
Latitude: 40.820000
Longitude: -80.760000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Change of Owner 2011-08-05 Operator changed from 9998, HISTORIC OWNER to 22, COLUMBIA GAS TRANSMISSION
Record Last Modified 2011-08-17

For data sources see[2]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1099111744 2018-2-15 0:00: SO No Violations 0.30
-1437594753 2020-1-13 0:00: SO No Violations 1.00
-40470103 2017-3-2 0:00:0 SO No Violations 0.30
0040470103 2017-03-02 Storage Well No Violations The purpose of my inspection was to conduct a status check on well # 6-2732. The access road was stable and drivable. The well location was stable with well established vegetation. Correct and legible identification was present at the well. The well head annular side ports were plumbed above grade. The South side valve was in the closed position and plugged. The North side valve was in the open position and plugged. The top of the well head was equipped with a master gate valve and two side gate valves. The South side gate valve was capped. A 4 line was plumbed out of the North side gate valve and into a vertical drip. A 4 line was plumbed out of the drip. A domestic supply connection was present. Test valves were closed and plugged. No audible or visual leaks were detected. No violations were detected during this inspection.
0051585418 2014-11-06 Storage Well No Violations I inspected Columbia Gas Transmission gas well #4521. The well is equipped with a master gate valve that is plumbed up to a side gate valve. The side gate valve is plumbed into a 4.00 lead line that runs through a drip tank and goes into the main line. The annulus valve is plumbed up and closed. The well is properly identified with a clear, legibly marked well identification sign. The lease road is in stable condition and drivable. No violations found.
0292667080 2015-04-21 Storage Well No Violations I conducted a status check on this well. The well is equipped with a master gate valve that is plumbed up to a side gate valve. The side gate valve is plumbed into a 4.00 lead line that runs through a drip tank and goes into the main line. The well is properly identified with a clear, legibly marked well identification sign. The lease road is in stable condition and drivable. No violations found.
0299245382 2019-04-04 Storage Well No Violations The production casing to this storage well was equipped with a flow cross which was topped with a cap that contained a test port. One wing valve was capped. The other wing valve was connected to a 4.5 line leading to a vertical drip before the lead line. The access road was stable. Proper identification was posted. No violations were observed at the time of inspection.
1079363083 2019-10-1 0:00: SO No Violations 1.00
1082051652 2013-05-08 Storage Well No Violations I inspected Columbia Gas Transmission gas well # 4521 today. The well is located in Section 36, Salem Township, Columbiana County, Ohio. The well is equipped with a master gate valve that is plumbed up to a side gate valve and a needle valve. The side gate valve is plumbed into a 4 lead line. The annulus valve is plumbed up and is closed. There is no tank on location. The well is properly identified with a clear, legible identification sign. The lease road is in stable condition. No violations found.
1099111744 2018-02-15 Storage Well No Violations The purpose of my inspection was to conduct a status check on well #62732. Access to the well was stable and drivable. Correct identification was posted at the well. The surface casing was plumbed above grade. Annular valves were closed to atmosphere. The production casing was equipped with a flow cross. The cross was topped with a cap that contained a test port. The sides of the cross contained wing valves. One wing valve was capped. The other wing valve was connected to a 4.5 line leading to a vertical drip before the lead line. No leaks were observed. No violations were observed during this inspection.
2115942883 2016-03-07 Storage Well No Violations I conducted a status check on this well. The well is equipped with a master gate valve that is plumbed up to a side gate valve. The side gate valve is plumbed into a 4.00 lead line that runs through a drip tank and goes into the main line. There was a domestic line with a meter. The well is properly identified with a clear, legibly marked well identification sign. The lease road is in stable condition and drivable. No violations found.
292667080 2015-4-21 0:00: SO No Violations
299245382 2019-4-4 0:00:0 SO No Violations
51585418 2014-11-6 0:00: SO No Violations

For data sources see[3]