34-029-60785

Well Details

Well ID: 34-029-60785
Loading map...
Country: United States
State: Ohio
County: Columbiana
Municipality: Elkrun Township
Operator Name: COLUMBIA GAS TRANSMISSION LLC
Well Pad ID:
Farm/Lease Name: BURT EDITH L
License Status: Storage Well
License Date: 1960-05-13
Spud Date: 1960-06-29
Spud Drilling Contractor:
Final Drill Date: 1960-09-27
Well Total Depth: 895.00 ft
Configuration: Vertical
Latitude: 40.810000
Longitude: -80.690000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1960-06-29
Completed 1960-09-27
Reached Total Depth 1960-09-27
Change of Owner 2011-08-05 Operator changed from 9998, HISTORIC OWNER to 22, COLUMBIA GAS TRANSMISSION
Record Last Modified 2011-08-17

For data sources see[2]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
0 0 0 R.P. 48 HRS.

For data sources see[3]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1202824795 2013-12-10 0:00 SO No Violations
-1579108304 2020-1-23 0:00: SO No Violations 1.00
-2053617690 2018-10-4 0:00: SO No Violations 0.30
-408685457 2014-11-7 0:00: SO No Violations 0.30
0408685457 2014-11-07 Storage Well No Violations I inspected Columbia Gas storage well #4571. The well is equipped with a master gate valve. There was no storage tank associated with the well. The well is properly identified with a clear, legibly marked well identification sign mounted on the storage tank. No violations found.
0873532200 2016-11-22 Storage Well No Violations I conducted a status check on this well. The well is equipped with a master gate valve that is plumbed up to a side gate valve. The side gate valve is plumbed into a 4.00 lead line that runs into the main line. The well is properly identified with a clear, legibly marked well identification sign. The lease road is in stable condition and drivable. No violations found.
1202824795 2013-12-10 Storage Well No Violations I inspected Columbia Gas Transmission gas well # 4571 today. The well is located in Fairfield Township, Columbiana County, Ohio. The well is considered to be an observation well. The well is equipped with a master gate valve that is plumbed up to a swedge with a fitting on it for a gauge. The annulus valve is plumbed up and is closed. There is no tank on location. The well is properly identified with a clear, legible identification sign. The lease road is in stable condition. No violations found.
1906300028 2015-09-02 Storage Well No Violations I conducted a status check on this well. The well is equipped with a master gate valve that is plumbed up to a side gate valve. The side gate valve is plumbed into a 4.00 lead line that runs into the main line. The well is properly identified with a clear, legibly marked well identification sign. The lease road is in stable condition and drivable. No violations found.
1991606990 2017-10-04 Storage Well No Violations The purpose of my inspection was to conduct a status check on well #6-0785. The lease access and well location were stable. Correct identification was present. Annular valves were closed and plugged. The well casing was equipped with a master gate valve that was capped. No leaks were observed. No violations were observed during this inspection.
2053617690 2018-10-04 Storage Well No Violations The purpose of my inspection was to conduct a status check inspection on well #6-0785. Access to the well was by foot through a residential yard. Correct identification was present. Well #6-0785 was configured as an observation well. The well head was above grade and the production casing annular ports were plugged. The 4.5 production casing was equipped with a master gate valve that contained a blind flange with a 1/2 observation port. All valves were closed. No leaks were observed. No violations were observed during this inspection.
873532200 2016-11-22 0:00 SO No Violations
879833200 2019-9-24 0:00: SO No Violations 1.00

For data sources see[4]