34-029-20401

Well Details

Well ID: 34-029-20401
Loading map...
Country: United States
State: Ohio
County: Columbiana
Municipality: Fairfield Township
Operator Name: COLUMBIA GAS TRANSMISSION LLC
Well Pad ID:
Farm/Lease Name: DAILEY H
License Status: Storage Well
License Date:
Spud Date: 1953-06-19
Spud Drilling Contractor:
Final Drill Date: 1953-11-25
Well Total Depth: 807.00 ft
Configuration: Vertical
Latitude: 40.820000
Longitude: -80.710000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1953-06-19
Completed 1953-11-25
Reached Total Depth 1953-11-25
Change of Owner 2011-08-05 Operator changed from 9998, HISTORIC OWNER to 22, COLUMBIA GAS TRANSMISSION
Record Last Modified 2011-08-17

For data sources see[2]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
0 0 0 1ST R.P. 230 1/2-120 HRS., 2ND R.P. 218#-48 HRS.

For data sources see[3]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1067365253 2017-10-4 0:00: SO No Violations 0.30
-1093233718 2020-1-23 0:00: SO No Violations 1.00
-1557454977 2018-10-4 0:00: SO No Violations 0.20
-549625095 2013-5-30 0:00: SO No Violations
-917036617 2014-11-7 0:00: SO No Violations 0.50
0112198378 2016-11-22 Storage Well No Violations I conducted a status check on this well. The well is equipped with a master gate valve that is plumbed up to a side gate valve. The side gate valve is plumbed into a 4.00 lead line that goes into the main line. The well is properly identified with a clear, legibly marked well identification sign. The lease road is in stable condition and drivable. No violations found.
0549625095 2013-05-30 Storage Well No Violations I inspected Columbia Gas Transmission gas well # 4240 today. The well is located in Section 32, Fairfield Township, Columbiana County, Ohio. The well is equipped with a master gate valve that is plumbed up to a side gate valve. The side gate valve is plumbed into a 4 lead line that goes into the main line. The annulus valve is plumbed up and is closed. There is no tank on location. The well is properly identified with a clear, legible identification sign. The lease road is in stable condition. No violations found.
0568578334 2015-09-02 Storage Well No Violations I conducted a status check on this well. The well is equipped with a master gate valve that is plumbed up to a side gate valve. The side gate valve is plumbed into a 4.00 lead line that runs into the main line. The well is properly identified with a clear, legibly marked well identification sign. The lease road is in stable condition and drivable. No violations found.
0917036617 2014-11-07 Storage Well No Violations I inspected Columbia Gas storage well #4240. The well is equipped with a master gate valve and a side gate valve. The pipe size was 3 from the side valve to the drip tank. There was no storage tank associated with the well. The well is properly identified with a clear, legibly marked well identification sign mounted on the storage tank. The lease road is stable. No violations found.
1067365253 2017-10-04 Storage Well No Violations The purpose of my inspection was to conduct a status check on well #2-0401. The lease access and well location were stable. Correct identification was present. Annular valves were closed and plugged. The well casing was equipped with a master gate valve topped with a swab valve head. A side gate valve was connected to the master gate valve. No leaks were observed. No violations were observed during this inspection.
112198378 2016-11-22 0:00 SO No Violations
1557454977 2018-10-04 Storage Well No Violations The purpose of my inspection was to conduct a status check on well #2-0401. Access to the well remained drivable and stable. Correct identification was present. The production casing annulus was closed to atmosphere. The production casing was equipped with a master gate valve. The master valve was topped with a capped riser that contained a wing valve The wing valve was connected to a 4.5 run that lead to the distribution system. All valves were closed. No leaks were observed. No violations were observed during this inspection.
173857337 2019-10-1 0:00: SO No Violations 1.00
568578334 2015-9-2 0:00:0 SO No Violations

For data sources see[4]

References