{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.85,"lon":-80.72,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Ashtabula | |
Municipality: Plymouth Township | |
Operator Name: BIG SKY ENERGY INC | |
Well Pad ID: | |
Farm/Lease Name: HOGAN | |
License Status: Producing | |
License Date: 1987-01-14 | |
Spud Date: 1987-02-01 | |
Spud Drilling Contractor: CO TOOLS | |
Final Drill Date: 1987-02-06 | |
Well Total Depth: 3166.00 ft | |
Configuration: Vertical | |
Latitude: 41.850000 | |
Longitude: -80.720000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Oil and Gas | 1987-01-14 | Issued Date 1/14/87 Expired Date 1/14/88 Acres 0000000 Tool Type RTF Proposed Formation CLINTON Proposed Depth 03166 Proposed Drill Depth 03166 |
Original Spud | 1987-02-01 | |
Completed | 1987-02-06 | |
Reached Total Depth | 1987-02-06 | |
CO | 1987-03-19 | 254 EDCO DRILLING & PRODUCING GeoDate 1/14/87 |
Completion Report Received | 1987-03-30 | |
Construction Permit Expires | 1988-01-14 | |
CO | 1993-12-15 | 1111 MERIDIAN ENERGY COMPANY GeoDate 1/14/87 |
Change of Owner | 2015-10-15 | Operator changed from 1111, MERIDIAN ENERGY COMPANY to 1333, BIG SKY ENERGY INC TRANSFERRED WELL PER CHANGE OF OWNER DATED 2/8/1999 ON 10/15/2015 CM. |
Record Last Modified | 2017-02-15 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-09-11 | 2976 | 2984 | 0 |
2959 | 3082 | 0 | |
1997-06-29 | 2959 | 3082 | 0 |
2976 | 2984 | 0 | |
2959 | 3082 | 0 | |
2006-09-11 | 3016 | 3026 | 0 |
2006-09-11 | 2996 | 3004 | 0 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 1500 Bbl | 50000 | FRAC W/1500 BW & 500 SX SAND | ||
ACID | 15 | 250 Gal | 0 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1987 | EDCO DRILLING & PRODUCING | 15417.00 | 0.00 | 365 |
1988 | EDCO DRILLING & PRODUCING | 8052.00 | 77.00 | 336 |
1989 | EDCO DRILLING & PRODUCING | 4949.00 | 89.00 | 365 |
1990 | EDCO DRILLING & PRODUCING | 4567.00 | 0.00 | 365 |
1991 | EDCO DRILLING & PRODUCING | 2977.00 | 60.00 | 365 |
1992 | EDCO DRILLING & PRODUCING | 2763.00 | 0.00 | 365 |
1993 | EDCO DRILLING & PRODUCING | 1463.00 | 0.00 | 200 |
1994 | MERIDIAN ENERGY COMPANY | 1754.00 | 0.00 | 365 |
1995 | MERIDIAN ENERGY COMPANY | 1323.00 | 0.00 | 365 |
1996 | MERIDIAN ENERGY COMPANY | 627.00 | 0.00 | 365 |
1997 | MERIDIAN ENERGY COMPANY | 649.00 | 0.00 | 365 |
1999 | MERIDIAN ENERGY COMPANY | 1410.00 | 0.00 | 365 |
2000 | MERIDIAN ENERGY COMPANY | 1752.00 | 35.00 | 365 |
2001 | BIG SKY ENERGY INC | 221.00 | 0.00 | 365 |
2002 | MERIDIAN ENERGY COMPANY | 0.00 | 109.00 | 365 |
2003 | MERIDIAN ENERGY COMPANY | 0.00 | 0.00 | 365 |
2004 | MERIDIAN ENERGY COMPANY | 0.00 | 0.00 | 0 |
2005 | MERIDIAN ENERGY COMPANY | 128.00 | 0.00 | 365 |
2006 | MERIDIAN ENERGY COMPANY | 597.00 | 0.00 | 365 |
2007 | MERIDIAN ENERGY COMPANY | 930.00 | 0.00 | 365 |
2008 | MERIDIAN ENERGY COMPANY | 1864.00 | 0.00 | 365 |
2009 | MERIDIAN ENERGY COMPANY | 1835.00 | 0.00 | 365 |
2010 | MERIDIAN ENERGY COMPANY | 1645.00 | 0.00 | 365 |
2011 | BIG SKY ENERGY INC | 145.00 | 0.00 | 365 |
2012 | BIG SKY ENERGY INC | 496.00 | 0.00 | 366 |
2013 | BIG SKY ENERGY INC | 174.00 | 6.00 | 250 |
2014 | BIG SKY ENERGY INC | 1.00 | 0.00 | 250 |
2016 | BIG SKY ENERGY INC | 0.00 | 0.00 | 0 |
2017 | BIG SKY ENERGY INC | 0.00 | 0.00 | 0 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1511234629 | 2017-10-31 0:00 | SC | No Violations | 0.50 |
-333815709 | 2006-10-20 0:00 | PW | No Violations | |
-710258836 | 2018-3-13 0:00: | PW | No Violations | 1.00 |
0270017113 | 2016-05-04 | Production Wells | Violations Noted | My inspection found the tank battery was equipped with one 100 barrel steel tank and one separator. There was no identification posted at the tank battery area. The well was equipped with a plunger lift unit. The valves from the well to the flow line were closed. There was a active domestic hook-up from the tubing head. This well was not in production at the time of my inspection. REQUIRED REMEDIAL WORK: Post identification at the tank battery area. |
0333815709 | 2006-10-20 | Production Wells | No Violations | no violations . |
0710258836 | 2018-03-13 | Production Wells | No Violations | I inspected this well pursuant to Chiefs Order #2016-300 issued for lack of insurance. The well and associated battery are located on a rural farm parcel. At the time of this inspection, I noted the following: a wellhead plunger-lift in a wooded clearing. The main flow-line valve was closed. The well was not in production. The fittings were secure with no signs of leakage. The associated tank battery was comprised of one 100-barrel production tank, and horizontal separator. The tank was empty. There was a chart record box that was not active. I walked the areas around the well and battery. The areas were covered with several inches of snow obscuring the ground surface. I did not observe any signs of problems. The elements were in disrepair. There was no identification signage. |
0761456009 | 2018-07-03 | Production Wells | No Violations | I inspected this well location as part of a compliance notice follow-up. As such, the following deficiencies had been noted: lack of complete identifying signage. At the time of this inspection, I noted the following: ID signage was still not present. The flow-line connections were closed and the chart recorder was not active. The areas surrounding the battery were overgrown significantly with phragmites. |
1511234629 | 2017-10-31 | Surface Facility Construction | No Violations | I inspected this well locaiton as part of a compliance notice follow-up. As such, the following defficieincies had been noted: lack of complete identifying signage. At the time of this inspection, I noted the following: a wellhead with plunger lift system and associated battery on a larger, rural parcel. The battery was comprised of one 100-barrel, steel production tank, and horizontal separator. Fittings and connections at the wellhead were secure with no signs of leakge. ID signage was not present. I noted the chart box was missing a chart. The areas surrounding the battery were overgrown signifiantly with phragmites. No changes had been made to the signage. |
270017113 | 2016-5-4 0:00:0 | PW | No Violations | |
761456009 | 2018-7-3 0:00:0 | PW | No Violations | 1.00 |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
0270017113 | US-OH-122794 | 2016-07-26 | 9-9-05(A)10 | Failure to legibly identify well |