Well Details

Well ID: 37-129-23062
Loading map...
Country: United States
State: Pennsylvania
County: Westmoreland
Municipality: Derry Township
Operator Name: FAIRMAN CORP
Well Pad ID:
Farm/Lease Name: MOLYNEAUX FARM
License Status: Plugged and Abandoned
Spud Date: 1987-12-02
Permit Date: 1987-11-10
Well Type: GAS
Unconventional Well: N
Configuration: Vertical Well
Conservation: No
Latitude: 40.405672
Longitude: -79.370506

For data sources see[1][2][3]

Well History

Date Event
1987-11-10 New Permit Application
1987-12-02 Performed Spud Operation
1987-12-06 Drilling Completion
1988-05-31 NEWLY DRILLED
2016-07-05 Begin Plugging
2016-07-11 Finished Plugging
2019-02-21 Fully Plugged

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2001 HOME GAS & OIL CO INC 1590 365 0.00 0 0.00 0
2003 HOME GAS & OIL CO INC 1296 365 0.00 0 0.00 0
2010 FAIRMAN CORP 696.00 365 0.00 0 0.00 0
2011 FAIRMAN CORP 583.5 365 0.00 0 0.00 0
2012 FAIRMAN CORP 508.28 365 0.00 0 0.00 0
2013 FAIRMAN CORP 617.5 365 0.00 0 0.00 0
2014 FAIRMAN CORP 195.00 151 0.00 0 0.00 0
2015 FAIRMAN CORP 313.5 183 0.00 0 0.00 0
2016 FAIRMAN CORP 0.00 0 0.00 0 0.00 0
2017 FAIRMAN CORP 0.00 0 0.00 0 0.00 0

For data sources see[5]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2500136 Primary Facility 2016-07-06 Plugging(Includes Plugged/Mined Through) No Violations Noted Rig had just run cement plug from 3476' to 1822' at the time of this inspection. Getting ready to run next plug. All equipment on site looked ok.
2501276 Primary Facility 2016-07-11 Plugging(Includes Plugged/Mined Through) No Violations Noted Inspection performed in response to the receipt of the Notice of Intention to Plug above referenced well. At the time of inspection well appears to have been plugged. Site stable with no E& S issues in relation to site and/or access road.
2504897 Primary Facility 2016-07-21 Plugging(Includes Plugged/Mined Through) No Violations Noted At the time of inspection well appears to be plugged. Site stable with no E& S issues in relation to site and/or access road.
2596756 Primary Facility 2017-05-23 Site Restoration No Violations Noted At the time of inspection site restored. 70% vegetative cover established. No E&S issues.
751948 Primary Facility 1987-11-20 Routine/Complete Inspection No Violations Noted SITE GRADED;E&S OK
751949 Primary Facility 1987-12-04 Routine/Complete Inspection Violation(s) Noted RD UNSTABLE;SILT DISCH
751950 Primary Facility 1987-12-07 Routine/Complete Inspection Violation(s) Noted ACCESS ROAD UNSTABLE
751951 Primary Facility 1987-12-22 Routine/Complete Inspection No Violations Noted PREV. VIOL. CORRECTED
751952 Primary Facility 1988-05-03 Routine/Complete Inspection No Violations Noted E&S OK
751953 Primary Facility 1988-08-19 Routine/Complete Inspection No Violations Noted TANK; E&S OK

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
751949 89116 12/04/1987 1987-12-04 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) Environmental Health & Safety ACCESS ROAD UNSTABLE
751949 89117 12/04/1987 1987-12-04 301307 - Unpermitted discharge of IW (brine, drill cuttings, & oil spills) Environmental Health & Safety SILT DISCHARGE
751949 89118 12/04/1987 1987-12-04 401 - Unpermitted discharge of pollutants. Used for sediment discharges & similar discharges not identified as an IW or directly related to trmt or drilling Environmental Health & Safety SILT DISCHARGE
751950 89119 12/07/1987 1987-12-07 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) Environmental Health & Safety ACCESS ROAD UNSTABLE

For data sources see[6]