X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-125-28026

Well Details

Well ID: 37-125-28026
Loading map...
Country: United States
State: Pennsylvania
County: Washington
Municipality: Carroll Township
Operator Name: EQT PROD CO
Well Pad ID: 148479
Farm/Lease Name: HAYWOOD 593745
License Status:
Spud Date:
Permit Date: 2016-08-11
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 40.178697
Longitude: -79.975969

For data sources see[1][2][3]

Well History

Date Event
2016-08-11 New Permit Application
2016-08-29 Performed Spud Operation
2017-08-07 MOD

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2017-10-21 2017-11-23 7,649 30,923,100 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 KFR-23 Keane Friction Reducer Water 7732-18-5 50 0.0476971 142296
Hydrochloric Acid (15%) Keane Acidizing Listed Below
KWBO-2 Keane Breaker Listed Below
Sand (Proppant) Keane Proppant Listed Below
Other Chemical(s) Listed Above See Trade Name(s) List Water 7732-18-5 89.7 0.00531529 15857.3
xylene 1330-20-7 5 0.00001143 34.097
copolymer of 2-propenamide 69418-26-4 20 0.0190788 56918.5
Sodium hypochlorite 7681-52-9 16 0.000948101 2828.5
Solvent naphtha (petroleum) heavy aliph. 64742-96-7 60 0.00355538 10606.9
Sodium hydroxide 1310-73-2 5 0.000296282 883.906
Fatty imidazoline 61790-69-0 5 0.00001143 34.097
Sodium persulfate 7775-27-1 99 0.00586638 17501.3
Guar gum 9000-30-0 60 0.00355538 10606.9
Sodium hypochlorite 7681-52-9 16 0.000948101 2828.5
isopropyl alcohol 67-63-0 5 0.00001143 34.097
Distillates (petroleum), hydrotreated light 64742-47-8 20 0.0190788 56918.5
methanol 67-56-1 30 0.00359867 10736
xylene 1330-20-7 5 0.00001143 34.097
prop-2-yn-1-ol 107-19-7 5 0.00001143 34.097
ethylbenzene 100-41-4 1 0.00000229 6.819
methanol 67-56-1 90 0.000205725 613.745
prop-2-yn-1-ol 107-19-7 5 0.00001143 34.097
Sodium hydroxide 1310-73-2 5 0.000296282 883.906
Sodium persulfate 7775-27-1 99 0.00586638 17501.3
oleic acid diethanolamide 93-83-4 2 0.00190789 5691.85
Trade Secret Proprietary 10 0.000592563 1767.81
Silica Substrate 14808-60-7 100 13.2318 39,474,900.0
Guar gum 9000-30-0 60 0.00355538 10606.9
Solvent naphtha (petroleum) heavy aliph. 64742-96-7 60 0.00355538 10606.9
Trade Secret Proprietary 10 0.000592563 1767.81
Hydrochloric Acid 7647-01-0 15 0.0223578 66700.8
alcohols, C12-16, ethoxylated 68551-12-2 2 0.00190789 5691.85
ethylbenzene 100-41-4 1 0.00000229 6.819
methanol 67-56-1 90 0.000205725 613.745
Alcohols, C7-9iso-, C8-rich 68526-83-0 5 0.00001143 34.097
Alcohols, C7-9iso-, C8-rich 68526-83-0 5 0.00001143 34.097
isopropyl alcohol 67-63-0 5 0.00001143 34.097
Fatty imidazoline 61790-69-0 5 0.00001143 34.097
KWG-111L Keane Gelling Agent Water 7732-18-5 89.7 0.00531529 15857.3
KSI-19 Keane Scale Inhibitor Listed Below
KAI-12 Keane Acid Inhibitor Listed Below
Water Keane Carrier/Base Fluid Water 7732-18-5 100 86.4983 258,053,000.0
BrOX Dirk Thomas Biocide Listed Below

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2016 EQT PROD CO 0.00 0 0.00 0 0.00 0
2017 EQT PROD CO 675,053.00 20 0.00 0 0.00 0
2018 EQT PROD CO 9,078,183.00 312 0.00 0 0.00 0
2019 EQT PROD CO 3,711,794.00 259 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2017 EQT PROD CO Drill Cuttings 2,204.94 Tons LANDFILL 100277
2017 EQT PROD CO Synthetic Liner Materials 40.32 Tons LANDFILL 100277
2017 EQT PROD CO Drilling Fluid Waste 15.00 Bbl RESIDUAL WASTE PROCESSING FACILITY ORDER 2016-29
2017 EQT PROD CO Other Oil & Gas Wastes 820.00 Bbl REUSE (AT WELL PAD)
2017 EQT PROD CO Unused Fracturing Fluid Waste 11.85 Tons RESIDUAL WASTE PROCESSING FACILITY 2014-541
2017 EQT PROD CO Other Oil & Gas Wastes 140.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017 EQT PROD CO Drilling Fluid Waste 785.00 Bbl REUSE (AT WELL PAD)
2017 EQT PROD CO Produced Fluid 1,444.88 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017 EQT PROD CO Produced Fluid 80.74 Tons RESIDUAL WASTE PROCESSING FACILITY ORDER 2016-29
2017 EQT PROD CO Produced Fluid 40.67 Bbl INJECTION DISPOSAL WELL 34-031-27177
2017 EQT PROD CO Produced Fluid 9,109.58 Bbl REUSE (AT WELL PAD)
2017 EQT PROD CO Produced Fluid 49.41 Tons RESIDUAL WASTE PROCESSING FACILITY 2014-541
2017 EQT PROD CO Synthetic Liner Materials 2.60 Tons LANDFILL 100663
2018 EQT PROD CO Produced Fluid 1,011.63 Bbl REUSE (AT WELL PAD)
2018 EQT PROD CO Other Oil & Gas Wastes 213.07 Bbl REUSE (AT WELL PAD)
2018 EQT PROD CO Produced Fluid 70.98 Bbl INJECTION DISPOSAL WELL 34-157-25511
2018 EQT PROD CO Other Oil & Gas Wastes 6.67 Bbl RESIDUAL WASTE PROCESSING FACILITY
2018 EQT PROD CO Other Oil & Gas Wastes 9.30 Tons LANDFILL 100419
2018 EQT PROD CO Other Oil & Gas Wastes 5.90 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2018 EQT PROD CO Other Oil & Gas Wastes 150.87 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018 EQT PROD CO Other Oil & Gas Wastes 0.95 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018 EQT PROD CO Other Oil & Gas Wastes 2.38 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE ORDER 2016-415
2018 EQT PROD CO Produced Fluid 92.90 Tons RESIDUAL WASTE PROCESSING FACILITY ORDER 2016-29
2018 EQT PROD CO Produced Fluid 271.39 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018 EQT PROD CO Synthetic Liner Materials 20.09 Tons LANDFILL 100277
2018 EQT PROD CO Produced Fluid 12,410.48 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018 EQT PROD CO Synthetic Liner Materials 60.61 Tons LANDFILL 100419
2019 EQT PROD CO Produced Fluid 41.58 Bbl SURFACE IMPOUNDMENT 95-7-37312-19
2019 EQT PROD CO Other Oil & Gas Wastes 40.71 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 EQT PROD CO Other Oil & Gas Wastes 4.56 Tons LANDFILL 100419
2019 EQT PROD CO Produced Fluid 17.03 Tons RESIDUAL WASTE PROCESSING FACILITY ODNR 2015-511
2019 EQT PROD CO Produced Fluid 251.44 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 EQT PROD CO Produced Fluid 44.68 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2019 EQT PROD CO Other Oil & Gas Wastes 10.48 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2019 EQT PROD CO Other Oil & Gas Wastes 159.56 Bbl REUSE (AT WELL PAD)
2019 EQT PROD CO Produced Fluid 3.71 Bbl RESIDUAL WASTE PROCESSING FACILITY
2019 EQT PROD CO Produced Fluid 9,269.39 Bbl REUSE (AT WELL PAD)
2019 EQT PROD CO Synthetic Liner Materials 16.29 Tons LANDFILL 100419
2019 EQT PROD CO Produced Fluid 145.05 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2019 EQT PROD CO Produced Fluid 156.66 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW010

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2515709 Primary Facility 2016-09-01 Drilling/Alteration No Violations Noted Cellar Tech auger rig

Drilled a 30” wellbore and set 26” conductor casing at 40 ft. on 8/31/16.

2525688 Primary Facility 2016-10-05 Drilling/Alteration No Violations Noted Alpha Hunter Drilling Rig #

Moved onto this well on 9/25/16 and resumed drilling at 50 ft. KB. The 18 5/8” casing was set at 382 ft. on 9/25/16 and cemented to surface with 30 bbls returned. The 13 3/8” casing was set at 480 ft. on 9/26/16 and grouted to surface above the basket. Coal was found from 425 ft. to 430 ft. A basket was set at 393 ft. The 9 5/8” casing was set at 2100 ft. on 9/28/16 and cemented to surface with 47 bbls returned. A Casing Annulus Packer was set in the 9 5/8” casing string from 1245 ft. to 1267 ft. (with 6 ft. pup joints above and below the packer). The KOP was at 5489 ft. TD was at 7145 ft. MD on 10/3/16.

2549509 Primary Facility 2016-12-06 Routine/Partial Inspection No Violations Noted On 12/6/16, I performed a routine partial inspection of the Harold Haywood in response to observed activity on site and made the following observations:

•A drilling rig was being constructed on site at the time of inspection. •A large panel had been set on the pad near the juncture of the pad and access road with a chemical container, multiple metal drums, and multiple pieces of oil covered equipment. A small amount of oil had reached the pad surface. The situation was pointed out to site personnel and was then promptly remediated including removal of all visibly impacted pad material. No violation. •A coil of hose was also found off containment dripping oily material to the pad surface and was promptly removed. No violation.

2553011 Primary Facility 2016-12-16 Follow-up Inspection No Violations Noted On December 16, 2016 I performed a follow up inspection at the Howard Haywood site in response to concerns noted in a previous inspection (ID: 2549486) of the site on 12/6/16 and made the following observations:

•On 12/6/16 multiple issues with containment and minor spills were noted to site personnel and immediately remediated. •Near the junction of the site access road and the pad a large metal plate had been placed so that it was crushing and compromising the containment around multiple pallets of chemicals marked “AES Drilling Fluids”. Multiple other empty chemical storage containers were also found without any containment. This is a violation of 58 Pa. C.S. § 3218.2(d) for failing to provide containment with at least 110% capacity on regulated substances. •A spill of more than ten gallons of antifreeze was found off of containment near the drill rig. The situation was immediately communicated to site personnel for remediation. This constitutes a violation of 25 Pa. Code § 78.57(a) and 25 Pa. Code

2587310 Primary Facility 2017-04-26 Routine/Partial Inspection No Violations Noted On 4/24/17 a RTPT inspection was conducted of the Harold Haywood site. The following was observed.

>Multiple areas along the access road bear sparse or patchy vegetation increasing risk of erosion. No violation, remediation recommended.

>A topsoil pile near the pad entrance is only partially stabilized with straw. No violation, remediation recommended.

> Drilling activity was concluded at the time of inspection and removal of drilling and completion equipment was underway.

> The AST remained on site at time of inspection.

2631394 Primary Facility 2017-08-25 Drilling/Alteration No Violations Noted Precision Drilling Rig #110

Moved onto this well on 8/16/17 and resumed drilling at 7154 ft. KB. KOP was at 5540 ft. (with air rig). EOB was at 8615 ft. MD (7694 ft. TVD). Currently at 11,615 ft. and drilling ahead.

2639827 Primary Facility 2017-09-13 Drilling/Alteration No Violations Noted Precision Rig #110 drilled to TD at 25,756 ft. MD on 9/7/17. Started to TOOH on 9/8/17. Got 39 stands of drill pipe out of hole. Started to circulate around 21,975 ft. And drill string became stuck. Operator feels drill string broke near BHA due to weight being pulled. Currently TOOH. Operator unsure if they will attempt to fish prior to sidetrack.
2688490 Primary Facility 2018-01-30 Routine/Complete Inspection No Violations Noted On 1/30/18 a routine complete of the Haywood Pad was conducted, the following was observed:

>>Substantial equipment was found stored around the site including multiple lifts and vehicles as well as numerous lights, generators, and tanks. An above ground storage tank was found on site as well. Most equipment had adequate secondary containment. Some stored equipment did not, any leaked or spilled fluids would constitute a violation.

>>Wells on site appeared to be in various stages of completion with no rig on site.

2698994 Primary Facility 2017-09-05 Administrative/File Review No Violations Noted On 9/5/17 an administrative inspection related to the Harold Haywood was conducted regarding test results related to complaint ID 328174. No evidence was found in the sample results suggesting impact to the water supply by oil and gas activity.
2722665 Primary Facility 2018-03-27 Complaint Inspection No Violations Noted On 3/27/18 a complaint inspection was conducted in relation to the Harold Haywood Well Site in response to CTS ID: 332966. Sample 3401-071 was collected for chemistry and biological analysis.
2767379 Primary Facility 2018-08-15 Routine/Partial Inspection No Violations Noted On 8/15/18 a routine partial inspection of the Harold Haywood Site was conducted in response to increased activity at the pad. The following was observed:

>>The site was in drilling phase at the time of inspection. High activity was noted on the pad. A drilling rig was active on site at the time of inspection.

>>Multiple containers of contaminated equipment were found off containment resulting in minor impacts to the pad. This constitutes a violation of 25 Pa. Code § 78.54 and 25 Pa. Code § 78.57(a) in that the operator failed to control regulated materials in a manner that prevents pollution to the ground and Waters of the Commonwealth. Any equipment with the potential to cause pollution including equipment contaminated with petroleum residues should be placed and stored on containment. Runoff from improperly stored equipment will result in violations.

>>Staining found on the pad near the office trailer suspected to be petroleum based (material was hydrophobic and greasy). This constitutes a viola

2790130 Primary Facility 2018-05-01 Administrative/File Review No Violations Noted On 5/1/18 an administrative inspection related to the Haywood site was conducted to analyze results from sample 3401071 related to complaint ID 332966 collected on 3/27/18. Sample analysis found that while the water did not meet state drinking water standards no clear indicators of oil and gas impact were present.
2805741 Primary Facility 2018-11-02 Incident- Response to Accident or Event No Violations Noted On 11/2/18 a complaint inspection of the Harold Haywood well site was conducted in response an operator reported spill. The following was observed:

>>On 10/31/18 an EQT representative reported that 15 gallons of "impaired water" was spilled to the pad.

>>At the time of inspection an operator representative reported that the standing water along the bottom of the AST was found to have very high conductivity during a routine check. The impacted water was pumped out. Field testing of standing water at the time of inspection found water at the site of the initial spill remained impacted with conductivity reading at roughly 1040us. Per the representative the standing water at the time of inspection was believed to be rain water from storms after the initial spill. The impacted water at the time inspection was substantially greater than the 15 gallons initially reported and was in addition to the initial spill. This constitutes a violation of 25 Pa. Code § 78.54 and 25 Pa. Code § 78.57(a) in that the opera

2831251 Primary Facility 2019-01-22 Compliance Evaluation No Violations Noted On 1/22/19 a compliance evaluation inspection of the Harold Haywood Well Site was conducted in response to violations recorded on 11/2/18 and 12/16/16. The following was observed:

>>No apparent residual impact related to spill violations from either date were observed. Containment around the AST on site may conceal further impact. No violation.

>>Violations related to non-GPU containment were remediated around time of 12/16/16 inspection and addressed with the operator at the time.

>>GPUs on site continued to lack containment at the time of inspection including on units installed post 10/2016. Violations ongoing.

2845282 Primary Facility 2019-02-19 Routine/Complete Inspection No Violations Noted Well and pad appear to be in good condition. There are 8 flow back tanks on site and 1 large water tank.
2863303 Primary Facility 2018-09-07 Administrative/File Review No Violations Noted On 9/7/18 an administrative inspection related to the Harold Haywood Pad was conducted to analyze sample and case information pertaining to a water supply complaint (CTS ID: 332966). No evidence of impact was found.

For data sources see[8]

References