37-125-27886

Well Details

Well ID: 37-125-27886
Loading map...
Country: United States
State: Pennsylvania
County: Washington
Municipality: Carroll Township
Operator Name: EQT PROD CO
Well Pad ID: 147813
Farm/Lease Name: WERNER 592699
License Status:
Spud Date:
Permit Date: 2016-02-10
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 40.189364
Longitude: -79.937556

For data sources see[1][2][3]

Well History

Date Event
2016-02-10 New Permit Application
2016-02-13 Performed Spud Operation
2016-05-12 New Permit Application

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2018-09-16 2018-09-30 7,614 19,008,500 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Silver SI-800 Silverback Scale inhibitor Listed Below
Other Chemical(s) Listed Above See Trade Name(s) List Listed Below
Sand (Proppant) Keane Proppant Listed Below
Silver FR 931 Silverback polymer Water 7732-18-5 89.7 0.0134056 24247.1
Hydrochloric Acid (15%) Keane Acidizing Listed Below
KWG-11L Keane Gel Listed Below
Water Keane Carrier/Base Fluid Water 7732-18-5 100 87.7002 158,626,000.0
KWBO-2 Keane Breaker Listed Below
Sodium persulfate 7775-27-1 99 0.000352983 638.453
Silica Substrate 14808-60-7 100 12.0081 21,719,500.0
Proprietary Polymers Proprietary 60 0.0348071 62956.8
Polycarboxylic acid salt mixture Proprietary 40 0.00513312 9284.45
Petroleum Distillates, Hydrotreated Light Naphthenic 64742-53-6 60 0.0348071 62956.8
Alcohols, C7-9-iso-, C8-rich 68526-83-0 5 0.00001406 25.428
Alcohols, C7-9-iso-, C8-rich 68526-83-0 5 0.00001406 25.428
Petroleum Distillates, Hydrotreated Light Naphthenic 64742-53-6 60 0.0348071 62956.8
xylene 1330-20-7 5 0.00001406 25.428
Sodium Hypochlorite 7681-52-9 16 0.00239118 4325.01
Trade secret Proprietary 10 0.000214104 387.257
Guar gum 9000-30-0 60 0.00128462 2323.54
xylene 1330-20-7 5 0.00001406 25.428
Methanol 67-56-1 90 0.000253049 457.697
Solvent naphtha (petroleum) heavy aliph 64742-96-7 60 0.00128462 2323.54
Proprietary Polymers Proprietary 60 0.0348071 62956.8
Fatty imidazoline 61790-69-0 5 0.00001406 25.428
Solvent naphtha (petroleum) heavy aliph 64742-96-7 60 0.00128462 2323.54
Sodium Hypdroxide 1310-73-2 5 0.000747244 1351.57
Polycarboxylic acid salt mixture Proprietary 40 0.00513312 9284.45
Hydrochloric Acid 7647-01-0 15 0.0304725 55116.7
Guar gum 9000-30-0 60 0.00128462 2323.54
Fatty imidazoline 61790-69-0 5 0.00001406 25.428
Trade secret Proprietary 10 0.000214104 387.257
Sodium persulfate 7775-27-1 99 0.000352983 638.453
Isoproyl alcohol 67-63-0 5 0.00001406 25.428
Ethylbenzene 100-41-4 1 0.00000281 5.086
Ethylbenzene 100-41-4 1 0.00000281 5.086
prop-2-yn-1-ol 107-19-7 5 0.00001406 25.428
KAI-12 Keane Acid Corrosion inhibitor Listed Below
BrOX Dirk Thomas Bacteria treatment Listed Below

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2016 EQT PROD CO 0.00 0 0.00 0 0.00 0
2017 EQT PROD CO 0.00 0 0.00 0 0.00 0
2018 EQT PROD CO 1,305,475.00 75 0.00 0 0.00 0
2019 EQT PROD CO 3,517,634.00 365 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2016 EQT PROD CO Drilling Fluid Waste 1,090.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 EQT PROD CO Drill Cuttings 689.90 Tons LANDFILL 100419
2016 EQT PROD CO Other Oil & Gas Wastes 5.15 Tons LANDFILL 100419
2017 EQT PROD CO Produced Fluid 220.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017 EQT PROD CO Other Oil & Gas Wastes 114.00 Bbl REUSE (AT WELL PAD)
2017 EQT PROD CO Produced Fluid 1,140.00 Bbl REUSE (AT WELL PAD)
2017 EQT PROD CO Produced Fluid 0.52 Tons RESIDUAL WASTE PROCESSING FACILITY 2014-541
2018 EQT PROD CO Other Oil & Gas Wastes 332.50 Bbl REUSE (AT WELL PAD)
2018 EQT PROD CO Synthetic Liner Materials 28.91 Tons LANDFILL 100419
2018 EQT PROD CO Drilling Fluid Waste 0.14 Tons RESIDUAL WASTE PROCESSING FACILITY 301280
2018 EQT PROD CO Produced Fluid 37.97 Tons RESIDUAL WASTE PROCESSING FACILITY ODNR 2015-511
2018 EQT PROD CO Other Oil & Gas Wastes 6.47 Tons LANDFILL 100419
2018 EQT PROD CO Other Oil & Gas Wastes 44.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018 EQT PROD CO Produced Fluid 1,179.32 Bbl REUSE (AT WELL PAD)
2018 EQT PROD CO Produced Fluid 102.90 Tons RESIDUAL WASTE PROCESSING FACILITY 2014-541
2018 EQT PROD CO Produced Fluid 1,368.92 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018 EQT PROD CO Produced Fluid 65.02 Bbl RESIDUAL WASTE PROCESSING FACILITY ODNR 2014-4
2018 EQT PROD CO Produced Fluid 1,247.13 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018 EQT PROD CO Waste Water Treatment Sludge 18.68 Tons LANDFILL MID000724831
2018 EQT PROD CO Produced Fluid 124.12 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW009
2018 EQT PROD CO Synthetic Liner Materials 28.40 Tons LANDFILL 100277
2019 EQT PROD CO Other Oil & Gas Wastes 11.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 EQT PROD CO Synthetic Liner Materials 11.81 Tons LANDFILL 100277
2019 EQT PROD CO Waste Water Treatment Sludge 57.08 Tons STORAGE PENDING DISPOSAL OR REUSE MID0209062814
2019 EQT PROD CO Produced Fluid 109.40 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 EQT PROD CO Produced Fluid 63.66 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2019 EQT PROD CO Other Oil & Gas Wastes 89.40 Bbl REUSE (AT WELL PAD)
2019 EQT PROD CO Produced Fluid 445.85 Bbl RESIDUAL WASTE PROCESSING FACILITY
2019 EQT PROD CO Produced Fluid 10,017.80 Bbl REUSE (AT WELL PAD)
2019 EQT PROD CO Produced Fluid 67.86 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2019 EQT PROD CO Produced Fluid 3,594.92 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW010

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2451730 Primary Facility 2016-02-19 Drilling/Alteration No Violations Noted Cellar Tech auger rig

Drilled 30” wellbore and set 26” conductor casing at 40 ft. on 2/13/16.

2455304 Primary Facility 2016-03-02 Drilling/Alteration No Violations Noted Alpha Hunter Drilling Rig #6

Moved onto this well on 2/21/16 and resumed drilling at 53 ft. KB. The 18 5/8” casing was set at 127.6 ft. on 2/21/16 and cemented to surface with 28 bbls returned. The 13 3/8” casing was set at 250.4 ft. on 2/22/16 and grouted to surface above the basket. Coal was found from 204 ft. to 209 ft. A basket was set at 189 ft. The 9 5/8” casing was set at 1651.5 ft. on 2/23/16 and cemented to surface with 45 bbls returned. A casing annulus packer was set in the 9 5/8” casing string from 1233 ft. to 1243 ft. TD was at 5337 ft. on 2/25/16.

2487875 Primary Facility 2016-01-08 Routine/Partial Inspection No Violations Noted On 1/8/16, I performed a routine partial inspection at the Bernard Werner Site in response to an operator request to review the site in relation to an upcoming pre-op for a major modification/expansion and made the following observations:

•The site was in generally good condition and no earthwork had begun at the time of inspection. •Three active wells were on the site at the time of inspection, five further wells were permitted for the expanded pad, and one well was proposed but never materialized.

2489206 Primary Facility 2016-01-26 Preoperation Inspection No Violations Noted On 1/26/2016, I performed a preoperation inspection at the Bernard Werner site in response to an operator request and made the following observations:

•Site perimeter controls were in place and functional. •Areas of exposed earth on site that were not being actively worked on were noted to have been temporarily stabilized. •An area near the corner of the impoundment may allow water to leave the LOD. It is recommended that the CFS be extended to meet the nearby culvert. This recommendation was accepted by the operator at the time of inspection and approved as a redline request. No violation. •A roadside ditch sloping towards the pad was not rock lined at the time of inspection, due to directionality being towards site it is being considered an intermediate (not perimeter control). Per the operator it is expected to be finished by the end of the day. No violation. •Multiple redline changes were requested and approved during the inspection including addition of CFS near the entrance and the addition of two

2515190 Primary Facility 2016-05-24 Follow-up Inspection No Violations Noted On 5/24/16, I performed a follow up inspection at the Bernard Werner site monitoring issues noted on 1/26/16 (eFACTS ID: 2489198) and made the following observations:

•A moderately eroded ATV path extends from access road off site, reported to be land owner created. No violation. •The bank of the diversion channel on the up slope side of the access road was largely barren; no prominent erosion damage was noted. The diversion channel was otherwise completed and functional. No violation, remediation recommended. •The cut slope above the well pad was stabilized but was still very sparsely vegetated at the time of inspection. No violation. •The vertical shafts of 8 wells had been drilled on site and were awaiting further drilling at the time of inspection. •Additional bare or sparse patches of vegetation were found on the north side of the site access road near the well pad, one the cut slop between the well pad and the small accessory pad, and between the small pad and the impoundment. •Redline changes app

2525680 Primary Facility 2016-09-29 Drilling/Alteration No Violations Noted Patterson-UTI Drilling Rig #277

Moved onto this well on 9/15/16 and resumed drilling at 6544 ft. KB on 9/23/16. EOB on the curve was at 8298 ft. MD (7554 ft. TVD). TD was at 19,772 ft. MD (7599 ft. TVD) on 9/28/16. Currently TOOH to run 5 ½” casing.

2527419 Primary Facility 2016-10-13 Drilling/Alteration No Violations Noted Patterson-UTI Drilling Rig #277

The 5 ½” casing was set at 19,734 ft. on 10/2/16. The estimated TOC is at 2984 ft.

2628080 Primary Facility 2017-08-22 Routine/Complete Inspection No Violations Noted On 8/22/17 an RTNC inspection of the Bernard Werner well site was conducted. The following was observed:

>>The site appeared stable and in generally good condition.

>>10 wells were observed at the time of inspection.

>>A section of CFS was found near the impoundment in a well vegetated area that should either be maintained or removed.

2666248 Primary Facility 2017-11-28 Incident- Response to Accident or Event No Violations Noted On 11/28/17 an incident inspection of the Werner well site was conducted in response to a spill (CTS ID: 331105) reported on 11/23/17. The following was observed:

>>An area of disturbed earth near a juncture in the site access road was noted to be unstabilized at the time of inspection. No violation, remediation recommended.

>>The exact location of the spill was unable to be determined, operator contacts with detailed information were not available at the time of inspection. No violation, further information needed for determination.

2666904 Primary Facility 2017-12-01 Follow-up Inspection No Violations Noted On 12/1/17 an incident inspection of the Werner well site was conducted in response to a spill (CTS ID: 331105) reported on 11/23/17. The following was observed:

>>The initial report was of a truck rollover that resulted in an estimated spill of 20 gallons of oil to the roadside culvert. The spill was fully cleaned at the time of the initial inspection on 11/28/17 but the location of the spill was unable to be identified. Upon locating the site of the spill cleanup appears to be complete and without further impact. While this constitutes a violation of 25 Pa. Code 78.54 in the the operator failed to control fluids associated with well servicing it has been determined that the violation was immediately corrected.

>>The unstabilized disturbed area noted on 11/28/17 remained unstabilized at the time of inspection. Continued failure to provide temporary stabilization would constitute a violation under 25 Pa. Code 102.22(b)(1).

2667077 Primary Facility 2017-12-04 Follow-up Inspection No Violations Noted On 12/4/17 an FUI inspection was conducted in response to concerns noted during a prior inspection on 12/1/17. The following was noted:

>>The unstabilized area of the site noted during a prior inspection on 12/1/17 had been stabilized at the time of inspection. No violation.

>>A small area between a section of CFS near the road juncture and the drainage channel was not stabilized. CFS at this location was also noted to be damaged. Remediation is recommended, no violation.

2686042 Primary Facility 2018-01-23 Administrative/File Review No Violations Noted On 1/23/18 an administrative inspection related to the Werner Well site was conducted in response to a complaint (CTS ID: 325462). The operator reported the complainant's concerns of potential pollution of a spring used as a partial water supply. Direct contact with the complainant found that the water had a history of methane contamination but no new or ongoing evidence of contamination. Further investigation by the DEP was declined at this time.
2708137 Primary Facility 2018-03-14 Routine/Complete Inspection No Violations Noted Inspected well for Application for Inactive Status. Well was drilled to a TD of 19,744 ft. MD. Fracking was started on this well but not finished (as per operator production staff).
2715907 Primary Facility 2018-04-06 Routine/Partial Inspection No Violations Noted On 4/6/18 a routine partial inspection of the Werner Well Site was conducted in response to an operator request for permit termination review of an adjacent site. The following was observed:

>>An area at the juncture of the access road and the access road of a nearby pipeline site was found to be unstabilized with partially constructed controls and early indications of increased erosion damage. No violation, stabilization in accordance with permit conditions is strongly recommended.

>>The adjacent Werner to Smith Pipeline was reported as unconstructed with regards to the permit termination request. Evidence of pipeline construction within the planned ROW was noted as related to a separate permit.

2725881 Primary Facility 2018-04-27 Follow-up Inspection No Violations Noted On 4/27/18 a follow up inspection of the Werner well site was conducted in response to issues first noted during a 4/6/18 routine partial inspection related to permit termination of an adjacent site. The following was observed:

>>The area noted in inspection report 2715873 as unstabilized and displaying increased erosion remained in much the same condition without surface stabilization. No indication of any work being conducted in the general area during the 21 days between inspections was found. This constitutes a violation of 25 Pa. Code § 102.22(b)(1) in that the operator failed to stabilize an area during any cessation of work in excess of four days.

2815116 Primary Facility 2018-12-13 Compliance Evaluation No Violations Noted On 12/13/18 a compliance evaluation inspection of the Werner Well Site was conducted in response to violations initially noted on 4/27/18. The following was observed:

> The unstabilized area of the site that was the subject of the violations was found to be fully vegetated and stabilized with site BMPs installed. An adjacent area of recent earth work was also stabilized. No further violations were found.

For data sources see[8]

References