X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-125-27877

Well Details

Well ID: 37-125-27877
Loading map...
Country: United States
State: Pennsylvania
County: Washington
Municipality: Carroll Township
Operator Name: EQT PROD CO
Well Pad ID: 148479
Farm/Lease Name: HAYWOOD 593744
License Status:
Spud Date:
Permit Date: 2016-02-10
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 40.178672
Longitude: -79.975958

For data sources see[1][2][3]

Well History

Date Event
2016-02-10 New Permit Application
2016-05-16 Performed Spud Operation

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2018-02-12 2018-02-27 7,700 16,937,000 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Ammonium Persulfate 7727-54-0 100 0.00000278 4.59
Oleic Acid Diethanolamide 93-83-4 2 0.000678201 1119.91
Distillates (petroleum), hydrotreated light 64742-47-8 55 0.00001445 23.867
Dimethylcocoamine, bis(chloroethyl)
ether, diquaternary ammonium salt
68607-28-3 20 0.000173835 287.051
2,2,4-trimethylpentane-1,3-diol monoisobutyrate 25265-77-4 7 0.00002076 34.278
Copolymer of 2-Propenamide Proprietary 20 0.00678201 11199.1
Alcohols, C10-16, ethoxylated 0068002-97-1 50 0.00006679 110.295
Formaldehyde 0000050-00-0 1 0.00000134 2.206
Butyl Diglycol 0000112-34-5 75 0.00010019 165.442
Hydrotreated Distillate 64742-47-8 20 0.00678201 11199.1
Methanol 0000067-56-1 5 0.00000668 11.029
Copolymer of 2-Propenamide Proprietary 20 0.00678201 11199.1
Guar Gum 9000-30-0 55 0.00001445 23.867
Guar Gum 9000-30-0 55 0.00001445 23.867
Distillates (petroleum), hydrotreated light 64742-47-8 55 0.00001445 23.867
2,2,4-trimethylpentane-1,3-diol monoisobutyrate 25265-77-4 7 0.00002076 34.278
Alcohols, C10-16, ethoxylated 0068002-97-1 50 0.00006679 110.295
Methanol 67-56-1 10 0.00008692 143.526
Hydrotreated Distillate 64742-47-8 20 0.00678201 11199.1
Ethylene glycol 107-21-1 40 0.00982511 16224.1
Thiourea 0000062-56-6 1 0.00000134 2.206
Benzenesulfonic acid, dodecyl-,
compound with 2-aminoethanol (1:1)
26836-07-7 7 0.00002076 34.278
Contains no hazardous substances
in concentrations above
cut-off values according to the competent authoriy
Proprietary 100 0.00249517 4120.25
Proprietary Scale Inhibitor Proprietary 30 0.00736883 12168.1
Silica Substrate 14808-60-7 100 14.1489 23,363,900.0
Methanol 0000067-56-1 5 0.00000668 11.029
Dimethylcocoamine 61788-93-0 5 0.00004346 71.763
Ammonium Persulfate 7727-54-0 100 0.00000278 4.59
Alcohols, C12-16, Ethoxylated 68551-12-2 2 0.000678201 1119.91
Calcium Nitrate.4H2O 13477-34-4 100 0.0375877 62068.1
Isopropyl Alcohol 67-63-0 30 0.000260752 430.577
Alcohols, C12-16, Ethoxylated 68551-12-2 2 0.000678201 1119.91
Thiourea 0000062-56-6 1 0.00000134 2.206
Formaldehyde 0000050-00-0 1 0.00000134 2.206
Oleic Acid Diethanolamide 93-83-4 2 0.000678201 1119.91
Hydrochloric Acid 7647-01-0 15 0.0236487 39050.7
Benzenesulfonic acid, dodecyl-,
compound with 2-aminoethanol (1:1)
26836-07-7 7 0.00002076 34.278
AP Breaker Universal Breaker Water 7732-18-5 50 0.016955 27997.6
Unislick CST-LA Universal Friction Reducer Listed Below
WGA-7 Universal Gelling Agent Listed Below
NE-50 Universal Inverter Listed Below
Sand (Proppant) Universal Proppant Listed Below
Scale Hib PE-18 Universal Scale Inhibitor Listed Below
Unihib-G Universal Acid Corrosion Inhibitor Listed Below
MX-5-3886 Multi-Chem Bacteria Treatment Listed Below
DireCT New Park Drilling Fluids Lubricant Listed Below
MX-8-4543 Multi-Chem Bacteria Treatment Listed Below
Hydrochloric Acid (15%) Universal Acidizing Listed Below
Water Universal Carrier/Base Fluid Water 7732-18-5 100 85.5936 141,340,000.0
Other Chemical(s) Listed Above See Trade Name(s) List Water 7732-18-5 50 0.016955 27997.6

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2016 EQT PROD CO 0.00 0 0.00 0 0.00 0
2017 EQT PROD CO 0.00 0 0.00 0 0.00 0
2018 EQT PROD CO 3,992,416.00 252 0.00 0 0.00 0
2019 EQT PROD CO 2,561,815.00 363 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2016 EQT PROD CO Drill Cuttings 125.28 Tons LANDFILL 100592
2016 EQT PROD CO Drilling Fluid Waste 412.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW005
2016 EQT PROD CO Drill Cuttings 453.42 Tons LANDFILL 100663
2016 EQT PROD CO Drill Cuttings 108.48 Tons LANDFILL 100172
2017 EQT PROD CO Drilling Fluid Waste 390.00 Bbl REUSE (AT WELL PAD)
2017 EQT PROD CO Drill Cuttings 959.93 Tons LANDFILL 100419
2017 EQT PROD CO Produced Fluid 220.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017 EQT PROD CO Drilling Fluid Waste 40.00 Bbl CENT WASTE TRT FAC NPDES EPA ID: 748-163
2017 EQT PROD CO Produced Fluid 190.00 Bbl REUSE (AT WELL PAD)
2017 EQT PROD CO Drilling Fluid Waste 40.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE EPA ID: 748-163
2018 EQT PROD CO Other Oil & Gas Wastes 400.86 Bbl REUSE (AT WELL PAD)
2018 EQT PROD CO Produced Fluid 48.11 Bbl INJECTION DISPOSAL WELL 34-157-25511
2018 EQT PROD CO Other Oil & Gas Wastes 6.67 Bbl RESIDUAL WASTE PROCESSING FACILITY
2018 EQT PROD CO Drilling Fluid Waste 910.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018 EQT PROD CO Other Oil & Gas Wastes 5.90 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2018 EQT PROD CO Produced Fluid 666.98 Bbl REUSE (AT WELL PAD)
2018 EQT PROD CO Other Oil & Gas Wastes 360.87 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018 EQT PROD CO Other Oil & Gas Wastes 0.95 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018 EQT PROD CO Other Oil & Gas Wastes 2.38 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE ORDER 2016-415
2018 EQT PROD CO Produced Fluid 1.42 Tons RESIDUAL WASTE PROCESSING FACILITY 2014-541
2018 EQT PROD CO Produced Fluid 191.07 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018 EQT PROD CO Synthetic Liner Materials 7.00 Tons LANDFILL 100277
2018 EQT PROD CO Drilling Fluid Waste 130.00 Bbl REUSE (AT WELL PAD)
2018 EQT PROD CO Synthetic Liner Materials 20.54 Tons LANDFILL 100419
2018 EQT PROD CO Produced Fluid 5,078.16 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 EQT PROD CO Produced Fluid 42.11 Bbl SURFACE IMPOUNDMENT 95-7-37312-19
2019 EQT PROD CO Other Oil & Gas Wastes 40.71 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 EQT PROD CO Other Oil & Gas Wastes 165.00 Bbl REUSE (AT WELL PAD)
2019 EQT PROD CO Produced Fluid 85.61 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 EQT PROD CO Produced Fluid 545.41 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2019 EQT PROD CO Produced Fluid 8.65 Bbl RESIDUAL WASTE PROCESSING FACILITY
2019 EQT PROD CO Produced Fluid 3,749.55 Bbl REUSE (AT WELL PAD)
2019 EQT PROD CO Produced Fluid 70.59 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2019 EQT PROD CO Other Oil & Gas Wastes 4.57 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2019 EQT PROD CO Produced Fluid 232.85 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW010

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2484799 Primary Facility 2016-05-17 Drilling/Alteration No Violations Noted Cellar Tech auger rig

Drilled a 30” wellbore and set 26” conductor casing at 65 ft. on 5/17/16.

2492507 Primary Facility 2016-06-07 Drilling/Alteration No Violations Noted Pioneer Drilling Rig #72

Moved onto this well on 6/1/16 and resumed drilling at 85 ft. KB on 6/5/16. The 18 5/8” casing was set at 322 ft. on 6/5/16 and cemented to surface with 54 bbls returned. The 13 3/8” casing was set at 485 ft. on 6/7/16 and cemented to surface with 22 bbls returned. Coal was found from 435 ft. to 440 ft. A basket was set at 402 ft. Currently at 543 ft. and connecting wellhead.

2498613 Primary Facility 2016-07-05 Drilling/Alteration No Violations Noted Pioneer Drilling Rig #72

The 9 5/8” casing was set at 2106 ft. on 6/10/16 and cemented to surface with 30 bbls returned. A Casing Annulus Packer was set in the 9 5/8” casing string from 1238 ft. to 1248 ft. TD was at 6159 ft. on 6/13/16.

2549508 Primary Facility 2016-12-06 Routine/Partial Inspection No Violations Noted On 12/6/16, I performed a routine partial inspection of the Harold Haywood in response to observed activity on site and made the following observations:

•A drilling rig was being constructed on site at the time of inspection. •A large panel had been set on the pad near the juncture of the pad and access road with a chemical container, multiple metal drums, and multiple pieces of oil covered equipment. A small amount of oil had reached the pad surface. The situation was pointed out to site personnel and was then promptly remediated including removal of all visibly impacted pad material. No violation. •A coil of hose was also found off containment dripping oily material to the pad surface and was promptly removed. No violation.

2553010 Primary Facility 2016-12-16 Follow-up Inspection No Violations Noted On December 16, 2016 I performed a follow up inspection at the Howard Haywood site in response to concerns noted in a previous inspection (ID: 2549486) of the site on 12/6/16 and made the following observations:

•On 12/6/16 multiple issues with containment and minor spills were noted to site personnel and immediately remediated. •Near the junction of the site access road and the pad a large metal plate had been placed so that it was crushing and compromising the containment around multiple pallets of chemicals marked “AES Drilling Fluids”. Multiple other empty chemical storage containers were also found without any containment. This is a violation of 58 Pa. C.S. § 3218.2(d) for failing to provide containment with at least 110% capacity on regulated substances. •A spill of more than ten gallons of antifreeze was found off of containment near the drill rig. The situation was immediately communicated to site personnel for remediation. This constitutes a violation of 25 Pa. Code § 78.57(a) and 25 Pa. Code

2553251 Primary Facility 2017-01-13 Drilling/Alteration No Violations Noted Pioneer Drilling Rig #72

Moved onto this well on 1/9/17 and resumed drilling at 6169 ft. KB. EOB was at 9104 ft. MD (7703 ft. TVD). Currently at 13,043 ft. MD and TOOH for new BHA.

2553252 Primary Facility 2017-01-13 Drilling/Alteration No Violations Noted Pioneer Drilling Rig #72

TD was at 20,572 ft. MD (7649.74 ft. TVD) on 1/6/17. The 5 ½” casing was set at 20,569 ft. Estimated TOC is at 6500 ft.

2557429 Primary Facility 2017-01-25 Drilling/Alteration No Violations Noted Pioneer Drilling Rig #72

TD was at 19,343 ft. MD (7618 ft. TVD) on 1/17/17. The 5 ½” casing was set at 19,340 ft. Estimated TOC is at 6000 ft.

2586946 Primary Facility 2017-04-26 Routine/Partial Inspection No Violations Noted On 4/24/17 a RTPT inspection was conducted of the Harold Haywood site. The following was observed.

>Multiple areas along the access road bear sparse or patchy vegetation increasing risk of erosion. No violation, remediation recommended.

>A topsoil pile near the pad entrance is only partially stabilized with straw. No violation, remediation recommended.

> Drilling activity was concluded at the time of inspection and removal of drilling and completion equipment was underway.

> The AST remained on site at time of inspection.

2688481 Primary Facility 2018-01-30 Routine/Complete Inspection No Violations Noted On 1/30/18 a routine complete of the Haywood Pad was conducted, the following was observed:

>>Substantial equipment was found stored around the site including multiple lifts and vehicles as well as numerous lights, generators, and tanks. An above ground storage tank was found on site as well. Most equipment had adequate secondary containment. Some stored equipment did not, any leaked or spilled fluids would constitute a violation.

>>Wells on site appeared to be in various stages of completion with no rig on site.

2698981 Primary Facility 2017-09-05 Administrative/File Review No Violations Noted On 9/5/17 an administrative inspection related to the Harold Haywood was conducted regarding test results related to complaint ID 328174. No evidence was found in the sample results suggesting impact to the water supply by oil and gas activity.
2722622 Primary Facility 2018-03-27 Complaint Inspection No Violations Noted On 3/27/18 a complaint inspection was conducted in relation to the Harold Haywood Well Site in response to CTS ID: 332966. Sample 3401-071 was collected for chemistry and biological analysis.
2767373 Primary Facility 2018-08-15 Routine/Partial Inspection No Violations Noted On 8/15/18 a routine partial inspection of the Harold Haywood Site was conducted in response to increased activity at the pad. The following was observed:

>>The site was in drilling phase at the time of inspection. High activity was noted on the pad. A drilling rig was active on site at the time of inspection.

>>Multiple containers of contaminated equipment were found off containment resulting in minor impacts to the pad. This constitutes a violation of 25 Pa. Code § 78.54 and 25 Pa. Code § 78.57(a) in that the operator failed to control regulated materials in a manner that prevents pollution to the ground and Waters of the Commonwealth. Any equipment with the potential to cause pollution including equipment contaminated with petroleum residues should be placed and stored on containment. Runoff from improperly stored equipment will result in violations.

>>Staining found on the pad near the office trailer suspected to be petroleum based (material was hydrophobic and greasy). This constitutes a viola

2790119 Primary Facility 2018-05-01 Administrative/File Review No Violations Noted On 5/1/18 an administrative inspection related to the Haywood site was conducted to analyze results from sample 3401071 related to complaint ID 332966 collected on 3/27/18. Sample analysis found that while the water did not meet state drinking water standards no clear indicators of oil and gas impact were present.
2805705 Primary Facility 2018-11-02 Incident- Response to Accident or Event No Violations Noted On 11/2/18 a complaint inspection of the Harold Haywood well site was conducted in response an operator reported spill. The following was observed:

>>On 10/31/18 an EQT representative reported that 15 gallons of "impaired water" was spilled to the pad.

>>At the time of inspection an operator representative reported that the standing water along the bottom of the AST was found to have very high conductivity during a routine check. The impacted water was pumped out. Field testing of standing water at the time of inspection found water at the site of the initial spill remained impacted with conductivity reading at roughly 1040us. Per the representative the standing water at the time of inspection was believed to be rain water from storms after the initial spill. The impacted water at the time inspection was substantially greater than the 15 gallons initially reported and was in addition to the initial spill. This constitutes a violation of 25 Pa. Code § 78.54 and 25 Pa. Code § 78.57(a) in that the opera

2831229 Primary Facility 2019-01-22 Compliance Evaluation No Violations Noted On 1/22/19 a compliance evaluation inspection of the Harold Haywood Well Site was conducted in response to violations recorded on 11/2/18 and 12/16/16. The following was observed:

>>No apparent residual impact related to spill violations from either date were observed. Containment around the AST on site may conceal further impact. No violation.

>>Violations related to non-GPU containment were remediated around time of 12/16/16 inspection and addressed with the operator at the time.

>>GPUs on site continued to lack containment at the time of inspection including on units installed post 10/2016. Violations ongoing.

2845261 Primary Facility 2019-02-19 Routine/Complete Inspection No Violations Noted Well and pad appear to be in good condition. There are 8 flow back tanks on site and 1 large water tank.
2863186 Primary Facility 2018-09-07 Administrative/File Review No Violations Noted On 9/7/18 an administrative inspection related to the Harold Haywood Pad was conducted to analyze sample and case information pertaining to a water supply complaint (CTS ID: 332966). No evidence of impact was found.
2863227 Primary Facility 2018-09-07 Administrative/File Review No Violations Noted On 9/7/18 an administrative inspection related to the Harold Haywood Pad was conducted to analyze sample and case information pertaining to a water supply complaint (CTS ID: 332966). No evidence of impact was found.

For data sources see[8]

References