37-125-27876

Well Details

Well ID: 37-125-27876
Loading map...
Country: United States
State: Pennsylvania
County: Washington
Municipality: Carroll Township
Operator Name: EQT PROD CO
Well Pad ID: 148479
Farm/Lease Name: HAYWOOD 593743
License Status: Inactive
Spud Date: 2016-05-16
Permit Date: 2016-02-10
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 40.178644
Longitude: -79.975944

For data sources see[1][2][3]

Well History

Date Event
2016-02-10 New Permit Application
2016-05-16 Performed Spud Operation
2016-12-13 Drilling Completion
2017-01-18 Newly Drilled
2017-11-14 Inactive Well Request Granted

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2018-02-11 2018-02-27 7,710 9,207,200 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 MX-5-3886 Multi-Chem Bacteria Treatment Listed Below
NE-50 Universal Inverter Listed Below
Sand (Proppant) Universal Proppant Listed Below
DireCT New Park Drilling Fluids Lubricant Water 7732-18-5 50 0.0363129 32760.8
Water Universal Carrier/Base Fluid Water 7732-18-5 100 85.1648 76,834,100.0
Unihib-G Universal Acid Corrosion Inhibitor Listed Below
Scale Hib PE-18 Universal Scale Inhibitor Listed Below
MX-8-4543 Multi-Chem Bacteria Treatment Listed Below
Dimethylcocoamine 61788-93-0 5 0.00000337 3.038
Benzenesulfonic acid, dodecyl-,
compound with 2-aminoethanol (1:1)
26836-07-7 7 0.00000676 6.099
Alcohols, C12-16, Ethoxylated 68551-12-2 2 0.00145251 1310.43
Proprietary Scale Inhibitor Proprietary 30 0.00736386 6643.54
Silica Substrate 14808-60-7 100 14.5262 13,105,300.0
Alcohols, C10-16, ethoxylated 0068002-97-1 50 0.00007292 65.79
Copolymer of 2-Propenamide Proprietary 20 0.0145251 13104.3
Thiourea 0000062-56-6 1 0.00000146 1.316
Alcohols, C12-16, Ethoxylated 68551-12-2 2 0.00145251 1310.43
Butyl Diglycol 0000112-34-5 75 0.000109385 98.685
Oleic Acid Diethanolamide 93-83-4 2 0.00145251 1310.43
Methanol 0000067-56-1 5 0.00000729 6.579
Formaldehyde 0000050-00-0 1 0.00000146 1.316
Contains no hazardous substances
in concentrations above
cut-off values according to the competent authoriy
Proprietary 100 0.00246222 2221.37
Methanol 0000067-56-1 5 0.00000729 6.579
Oleic Acid Diethanolamide 93-83-4 2 0.00145251 1310.43
Thiourea 0000062-56-6 1 0.00000146 1.316
2,2,4-trimethylpentane-1,3-diol monoisobutyrate 25265-77-4 7 0.00000676 6.099
Methanol 67-56-1 10 0.00000673 6.075
Ethylene glycol 107-21-1 40 0.00981849 8858.06
Copolymer of 2-Propenamide Proprietary 20 0.0145251 13104.3
Hydrochloric Acid 7647-01-0 15 0.0257473 23228.7
Formaldehyde 0000050-00-0 1 0.00000146 1.316
Isopropyl Alcohol 67-63-0 30 0.00002020 18.225
Dimethylcocoamine, bis(chloroethyl)
ether, diquaternary ammonium salt
68607-28-3 20 0.00001347 12.15
Proprietary Scale Inhibitor Proprietary 30 0.00736386 6643.54
Hydrotreated Distillate 64742-47-8 20 0.0145251 13104.3
Calcium Nitrate.4H2O 13477-34-4 100 0.0374231 33762.4
Hydrotreated Distillate 64742-47-8 20 0.0145251 13104.3
Butyl Diglycol 0000112-34-5 75 0.000109385 98.685
2,2,4-trimethylpentane-1,3-diol monoisobutyrate 25265-77-4 7 0.00000676 6.099
Alcohols, C10-16, ethoxylated 0068002-97-1 50 0.00007292 65.79
Benzenesulfonic acid, dodecyl-,
compound with 2-aminoethanol (1:1)
26836-07-7 7 0.00000676 6.099
Other Chemical(s) Listed Above See Trade Name(s) List Water 7732-18-5 50 0.0363129 32760.8
Hydrochloric Acid (15%) Universal Acidizing Listed Below
Unislick CST-LA Universal Friction Reducer Listed Below

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2016 EQT PROD CO 0.00 0 0.00 0 0.00 0
2017 EQT PROD CO 0.00 0 0.00 0 0.00 0
2018 EQT PROD CO 2,172,177.00 291 0.00 0 0.00 0
2019 EQT PROD CO 587,431.00 358 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2016 EQT PROD CO Drilling Fluid Waste 1,720.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 EQT PROD CO Other Oil & Gas Wastes 130.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 EQT PROD CO Synthetic Liner Materials 3.35 Tons LANDFILL 100419
2016 EQT PROD CO Drill Cuttings 125.20 Tons LANDFILL 100592
2016 EQT PROD CO Drill Cuttings 605.05 Tons LANDFILL 100419
2016 EQT PROD CO Other Oil & Gas Wastes 2.75 Tons LANDFILL 100419
2016 EQT PROD CO Drill Cuttings 220.52 Tons LANDFILL 100663
2016 EQT PROD CO Drill Cuttings 168.76 Tons LANDFILL 100172
2017 EQT PROD CO Other Oil & Gas Wastes 5.00 Bbl REUSE (AT WELL PAD)
2017 EQT PROD CO Produced Fluid 670.00 Bbl REUSE (AT WELL PAD)
2018 EQT PROD CO Produced Fluid 290.17 Bbl REUSE (AT WELL PAD)
2018 EQT PROD CO Other Oil & Gas Wastes 2,330.77 Bbl REUSE (AT WELL PAD)
2018 EQT PROD CO Synthetic Liner Materials 74.84 Tons LANDFILL 100419
2018 EQT PROD CO Produced Fluid 18.35 Bbl INJECTION DISPOSAL WELL 34-157-25511
2018 EQT PROD CO Other Oil & Gas Wastes 6.67 Bbl RESIDUAL WASTE PROCESSING FACILITY
2018 EQT PROD CO Other Oil & Gas Wastes 5.90 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2018 EQT PROD CO Other Oil & Gas Wastes 160.87 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018 EQT PROD CO Other Oil & Gas Wastes 0.95 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018 EQT PROD CO Other Oil & Gas Wastes 2.38 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE ORDER 2016-415
2018 EQT PROD CO Produced Fluid 175.93 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018 EQT PROD CO Produced Fluid 3,888.19 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 EQT PROD CO Produced Fluid 22.97 Bbl SURFACE IMPOUNDMENT 95-7-37312-19
2019 EQT PROD CO Other Oil & Gas Wastes 40.71 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 EQT PROD CO Other Oil & Gas Wastes 15.72 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2019 EQT PROD CO Other Oil & Gas Wastes 226.95 Bbl REUSE (AT WELL PAD)
2019 EQT PROD CO Produced Fluid 1.26 Bbl RESIDUAL WASTE PROCESSING FACILITY
2019 EQT PROD CO Produced Fluid 11.07 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 EQT PROD CO Produced Fluid 33.62 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2019 EQT PROD CO Produced Fluid 1,320.54 Bbl REUSE (AT WELL PAD)
2019 EQT PROD CO Produced Fluid 8.90 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2019 EQT PROD CO Produced Fluid 61.81 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW010

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2484797 Primary Facility 2016-05-17 Drilling/Alteration No Violations Noted Cellar Tech auger rig

Drilled a 30” wellbore and set 26” conductor casing at 65 ft. on 5/17/16.

2494443 Primary Facility 2016-06-20 Drilling/Alteration No Violations Noted Pioneer Drilling Rig #72

Moved onto this well on 6/14/16 and resumed drilling at 81 ft. KB. The 18 5/8” casing was set at 322 ft. on 6/15/16 and cemented to surface with 50 bbls returned. The 13 3/8” casing was set at 471 ft. on 6/16/16 and cemented to surface with 20 bbls returned. Coal was found from 432 ft. to 437 ft. A basket was set at 425 ft. The 9 5/8” casing was set at 2106 ft. on 6/18/16 and cemented to surface with 37 bbls returned. A Casing Annulus Packer was set in the 9 5/8” casing string from 1248 ft. to 1261 ft. Currently at 3374 ft. and rigging down to move to another site temporarily.

2522511 Primary Facility 2016-09-23 Drilling/Alteration No Violations Noted Alpha Hunter Drilling Rig #8

Reentered this well on 9/22/16 and resumed drilling at 3374 ft. KB. KOP was at 3452 ft. Currently at 3969 ft. and drilling ahead.

2525684 Primary Facility 2016-10-05 Drilling/Alteration No Violations Noted Alpha Hunter Drilling Rig #8

TD was at 6000 ft. MD on 9/24/16.

2545287 Primary Facility 2016-12-14 Drilling/Alteration No Violations Noted Pioneer Drilling Rig #72

Moved onto this well on 12/2/16 and resumed drilling at 6004 ft. MD. KOP was at 6010 ft. EOB was at 9368 ft. MD (7707 ft. TVD). TD was at 15,044 ft. MD (7676 ft. TVD) on 12/13/16. Currently running 5 ½” casing.

2546018 Primary Facility 2016-12-20 Drilling/Alteration No Violations Noted Pioneer Drilling Rig #72

The 5 ½” casing was set at 15,038 ft. on 12/15/16. The estimated TOC is at 6500 ft.

2549507 Primary Facility 2016-12-06 Routine/Partial Inspection No Violations Noted On 12/6/16, I performed a routine partial inspection of the Harold Haywood in response to observed activity on site and made the following observations:

•A drilling rig was being constructed on site at the time of inspection. •A large panel had been set on the pad near the juncture of the pad and access road with a chemical container, multiple metal drums, and multiple pieces of oil covered equipment. A small amount of oil had reached the pad surface. The situation was pointed out to site personnel and was then promptly remediated including removal of all visibly impacted pad material. No violation. •A coil of hose was also found off containment dripping oily material to the pad surface and was promptly removed. No violation.

2553008 Primary Facility 2016-12-16 Follow-up Inspection No Violations Noted On December 16, 2016 I performed a follow up inspection at the Howard Haywood site in response to concerns noted in a previous inspection (ID: 2549486) of the site on 12/6/16 and made the following observations:

•On 12/6/16 multiple issues with containment and minor spills were noted to site personnel and immediately remediated. •Near the junction of the site access road and the pad a large metal plate had been placed so that it was crushing and compromising the containment around multiple pallets of chemicals marked “AES Drilling Fluids”. Multiple other empty chemical storage containers were also found without any containment. This is a violation of 58 Pa. C.S. § 3218.2(d) for failing to provide containment with at least 110% capacity on regulated substances. •A spill of more than ten gallons of antifreeze was found off of containment near the drill rig. The situation was immediately communicated to site personnel for remediation. This constitutes a violation of 25 Pa. Code § 78.57(a) and 25 Pa. Code

2586942 Primary Facility 2017-04-26 Routine/Partial Inspection No Violations Noted On 4/24/17 a RTPT inspection was conducted of the Harold Haywood site. The following was observed.

>Multiple areas along the access road bear sparse or patchy vegetation increasing risk of erosion. No violation, remediation recommended.

>A topsoil pile near the pad entrance is only partially stabilized with straw. No violation, remediation recommended.

> Drilling activity was concluded at the time of inspection and removal of drilling and completion equipment was underway.

> The AST remained on site at time of inspection.

2688479 Primary Facility 2018-01-30 Routine/Complete Inspection No Violations Noted On 1/30/18 a routine complete of the Haywood Pad was conducted, the following was observed:

>>Substantial equipment was found stored around the site including multiple lifts and vehicles as well as numerous lights, generators, and tanks. An above ground storage tank was found on site as well. Most equipment had adequate secondary containment. Some stored equipment did not, any leaked or spilled fluids would constitute a violation.

>>Wells on site appeared to be in various stages of completion with no rig on site.

2698979 Primary Facility 2017-09-05 Administrative/File Review No Violations Noted On 9/5/17 an administrative inspection related to the Harold Haywood was conducted regarding test results related to complaint ID 328174. No evidence was found in the sample results suggesting impact to the water supply by oil and gas activity.
2722599 Primary Facility 2018-03-27 Complaint Inspection No Violations Noted On 3/27/18 a complaint inspection was conducted in relation to the Harold Haywood Well Site in response to CTS ID: 332966. Sample 3401-071 was collected for chemistry and biological analysis.
2767371 Primary Facility 2018-08-15 Routine/Partial Inspection No Violations Noted On 8/15/18 a routine partial inspection of the Harold Haywood Site was conducted in response to increased activity at the pad. The following was observed:

>>The site was in drilling phase at the time of inspection. High activity was noted on the pad. A drilling rig was active on site at the time of inspection.

>>Multiple containers of contaminated equipment were found off containment resulting in minor impacts to the pad. This constitutes a violation of 25 Pa. Code § 78.54 and 25 Pa. Code § 78.57(a) in that the operator failed to control regulated materials in a manner that prevents pollution to the ground and Waters of the Commonwealth. Any equipment with the potential to cause pollution including equipment contaminated with petroleum residues should be placed and stored on containment. Runoff from improperly stored equipment will result in violations.

>>Staining found on the pad near the office trailer suspected to be petroleum based (material was hydrophobic and greasy). This constitutes a viola

2790117 Primary Facility 2018-05-01 Administrative/File Review No Violations Noted On 5/1/18 an administrative inspection related to the Haywood site was conducted to analyze results from sample 3401071 related to complaint ID 332966 collected on 3/27/18. Sample analysis found that while the water did not meet state drinking water standards no clear indicators of oil and gas impact were present.
2805711 Primary Facility 2018-11-02 Incident- Response to Accident or Event No Violations Noted On 11/2/18 a complaint inspection of the Harold Haywood well site was conducted in response an operator reported spill. The following was observed:

>>On 10/31/18 an EQT representative reported that 15 gallons of "impaired water" was spilled to the pad.

>>At the time of inspection an operator representative reported that the standing water along the bottom of the AST was found to have very high conductivity during a routine check. The impacted water was pumped out. Field testing of standing water at the time of inspection found water at the site of the initial spill remained impacted with conductivity reading at roughly 1040us. Per the representative the standing water at the time of inspection was believed to be rain water from storms after the initial spill. The impacted water at the time inspection was substantially greater than the 15 gallons initially reported and was in addition to the initial spill. This constitutes a violation of 25 Pa. Code § 78.54 and 25 Pa. Code § 78.57(a) in that the opera

2831235 Primary Facility 2019-01-22 Compliance Evaluation No Violations Noted On 1/22/19 a compliance evaluation inspection of the Harold Haywood Well Site was conducted in response to violations recorded on 11/2/18 and 12/16/16. The following was observed:

>>No apparent residual impact related to spill violations from either date were observed. Containment around the AST on site may conceal further impact. No violation.

>>Violations related to non-GPU containment were remediated around time of 12/16/16 inspection and addressed with the operator at the time.

>>GPUs on site continued to lack containment at the time of inspection including on units installed post 10/2016. Violations ongoing.

2845293 Primary Facility 2019-02-19 Routine/Complete Inspection No Violations Noted Well and pad appear to be in good condition. There are 8 flow back tanks on site and 1 large water tank.
2863182 Primary Facility 2018-09-07 Administrative/File Review No Violations Noted On 9/7/18 an administrative inspection related to the Harold Haywood Pad was conducted to analyze sample and case information pertaining to a water supply complaint (CTS ID: 332966). No evidence of impact was found.

For data sources see[8]

References