Well Details

Well ID: 37-125-27819
Loading map...
Country: United States
State: Pennsylvania
County: Washington
Municipality: Carroll Township
Operator Name: EQT PROD CO
Well Pad ID: 147813
Farm/Lease Name: WERNER 592701
License Status:
Spud Date:
Permit Date: 2015-12-22
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 40.189344
Longitude: -79.937478

For data sources see[1][2][3]

Well History

Date Event
2015-12-22 New Permit Application
2016-01-26 Performed Spud Operation
2016-05-12 New Permit Application

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2017-01-16 2017-01-27 7,547 14,423,900 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Other Chemical(s) Listed Above See Trade Name(s) List Listed Below
Sand (Proppant) FTS International Proppant Listed Below
CS-500 SI FTS International Scale Inhibitor Listed Below
CI-150 FTS International Acid Corrosion Inhibitor Listed Below
MC MX 5-3886 Multi-Chem Group Specialty Brine Listed Below
LD-2250 Multi-Chem Group Friction Reducer Listed Below
FRW-900 FTS International Friction Reducer Listed Below
Oxyalkylated alcohol A Proprietary 5 0.000331439 464.808
Hydrotreated light petroleum distillate 64742-47-8 30 0.0185028 25948.2
Calcium nitrate.4H2O 13477-34-4 100 0.105145 147454
Sodium nitrate 7631-99-4 5 0.000468192 656.59
Ethylene Glycol 107-21-1 10 0.00240232 3369.01
Sodium chloride 7647-14-5 10 0.00119815 1680.29
Calcium nitrate.4H2O 13477-34-4 100 0.105145 147454
Silica Substrate 14808-60-7 100 13.8047 19,359,600.0
Sodium nitrate 7631-99-4 5 0.000468192 656.59
Hydrotreated light petroleum distillate 64742-47-8 30 0.0185028 25948.2
Oxyalkylated alcohol A Proprietary 5 0.000331439 464.808
Sodium chloride 7647-14-5 100 0.00936384 13131.8
Polyacrylate Proprietary 30 0.0185028 25948.2
Aromatic aldehyde Proprietary 10 0.00002710 38.003
Sodium chloride 7647-14-5 5 0.0030838 4324.71
Quaternary ammonium compound Proprietary 10 0.00002710 38.003
Sodium chloride 7647-14-5 5 0.0030838 4324.71
Fatty nitrogen derived amides Proprietary 5 0.0030838 4324.71
Inner salt of alkyl amines Proprietary 60 0.00718893 10081.7
Ethylene Glycol 107-21-1 30 0.00008130 114.009
Sodium chloride 7647-14-5 100 0.00936384 13131.8
Hydrotreated Light Distillate 64742-47-8 30 0.00198863 2788.85
Ethoxylated alcohol Proprietary 5 0.0030838 4324.71
Alkyl Alcohol Proprietary 10 0.000662877 929.616
Inner salt of alkyl amines Proprietary 60 0.00718893 10081.7
Polyacrylate Proprietary 30 0.0185028 25948.2
Hydrochloric Acid 7647-01-0 15 0.0219664 30805.6
Alkyl Alcohol Proprietary 10 0.000662877 929.616
Organic amine resin salt Proprietary 30 0.00008130 114.009
Sodium chloride 7647-14-5 10 0.00119815 1680.29
Fatty nitrogen derived amides Proprietary 5 0.0030838 4324.71
Hydrotreated Light Distillate 64742-47-8 30 0.00198863 2788.85
Dimethylformamide 68-12-2 10 0.00002710 38.003
Ethoxylated alcohol Proprietary 5 0.0030838 4324.71
Isopropanol 67-63-0 30 0.00008130 114.009
LD-2550 Multi-Chem Group Additive Listed Below
MC MX 8-2544 Multi-Chem Group Live Culture - Nitrate Reducing Bacteria Listed Below
Hydrochloric Acid (15%) FTS International Acidizing Listed Below
Water FTS International Carrier/Base Fluid Water 7732-18-5 100 85.8298 120,367,000.0

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2016 EQT PROD CO 0.00 0 0.00 0 0.00 0
2017 EQT PROD CO 3,525,063.00 241 0.00 0 0.00 0
2018 EQT PROD CO 1,884,192.00 364 0.00 0 0.00 0
2019 EQT PROD CO 1,069,592.00 365 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2016 EQT PROD CO Drilling Fluid Waste 240.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 EQT PROD CO Other Oil & Gas Wastes 57.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 EQT PROD CO Drill Cuttings 1,016.86 Tons LANDFILL 100419
2016 EQT PROD CO Drill Cuttings 158.45 Tons LANDFILL 100277
2017 EQT PROD CO Produced Fluid 3,819.71 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017 EQT PROD CO Synthetic Liner Materials 6.48 Tons LANDFILL 100277
2017 EQT PROD CO Waste Water Treatment Sludge 31.02 Tons RESIDUAL WASTE PROCESSING FACILITY 2014-541
2017 EQT PROD CO Other Oil & Gas Wastes 1,177.00 Bbl REUSE (AT WELL PAD)
2017 EQT PROD CO Other Oil & Gas Wastes 110.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017 EQT PROD CO Drilling Fluid Waste 730.00 Bbl REUSE (AT WELL PAD)
2017 EQT PROD CO Produced Fluid 70.27 Bbl INJECTION DISPOSAL WELL 34-031-27177
2017 EQT PROD CO Produced Fluid 23.65 Bbl RESIDUAL WASTE PROCESSING FACILITY
2017 EQT PROD CO Produced Fluid 9,926.19 Bbl REUSE (AT WELL PAD)
2017 EQT PROD CO Produced Fluid 94.55 Tons RESIDUAL WASTE PROCESSING FACILITY 2014-541
2017 EQT PROD CO Produced Fluid 13.27 Bbl INJECTION DISPOSAL WELL 34-157-25511
2018 EQT PROD CO Other Oil & Gas Wastes 185.00 Bbl REUSE (AT WELL PAD)
2018 EQT PROD CO Produced Fluid 546.12 Bbl REUSE (AT WELL PAD)
2018 EQT PROD CO Other Oil & Gas Wastes 44.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018 EQT PROD CO Soil Contaminated by Oil & Gas Related Spills 6.21 Tons LANDFILL 100419
2018 EQT PROD CO Produced Fluid 13.34 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW009
2018 EQT PROD CO Soil Contaminated by Oil 6.21 Tons LANDFILL 100419
2018 EQT PROD CO Produced Fluid 141.14 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018 EQT PROD CO Produced Fluid 6.99 Bbl RESIDUAL WASTE PROCESSING FACILITY ODNR 2014-4
2018 EQT PROD CO Produced Fluid 714.28 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 EQT PROD CO Produced Fluid 130.98 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE ORDER 2016-415
2019 EQT PROD CO Produced Fluid 8.58 Bbl INJECTION DISPOSAL WELL 34-059-24202
2019 EQT PROD CO Produced Fluid 33.52 Bbl RESIDUAL WASTE PROCESSING FACILITY ODNR 2014-4
2019 EQT PROD CO Other Oil & Gas Wastes 187.40 Bbl REUSE (AT WELL PAD)
2019 EQT PROD CO Produced Fluid 32.54 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 EQT PROD CO Produced Fluid 3.03 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2019 EQT PROD CO Produced Fluid 499.92 Bbl REUSE (AT WELL PAD)
2019 EQT PROD CO Produced Fluid 33.97 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2019 EQT PROD CO Produced Fluid 57.25 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW010

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2445113 Primary Facility 2016-01-29 Drilling/Alteration No Violations Noted Cellar Tech auger rig

Drilled a 30” wellbore and set 26” conductor casing at 40 ft. on 1/27/16.

2446921 Primary Facility 2016-02-04 Drilling/Alteration No Violations Noted Alpha Hunter Drilling Rig #6

Moved onto this well on 2/3/16 and resumed drilling at 40 ft. The 18 5/8” casing was set at 127 ft. on 2/3/16 and cemented to surface with 20 bbls returned. The 13 3/8” casing was set at 254 ft. on 2/4/16 and cemented to surface with 5 bbls returned. Coal was found from 204 ft. to 209 ft. A basket was set at 174 ft. Currently at 304 ft. and waiting on cement.

2449077 Primary Facility 2016-02-11 Drilling/Alteration No Violations Noted Alpha Hunter Drilling Rig #6

The 9 5/8” casing was set at 1651 ft. on 2/5/16 and cemented to surface with 16 bbls returned. A casing annulus packer was set in the 9 5/8” casing string from 1230 ft. to 1240 ft. TD was at 5870 ft. on 2/7/16.

2487872 Primary Facility 2016-01-08 Routine/Partial Inspection No Violations Noted On 1/8/16, I performed a routine partial inspection at the Bernard Werner Site in response to an operator request to review the site in relation to an upcoming pre-op for a major modification/expansion and made the following observations:

•The site was in generally good condition and no earthwork had begun at the time of inspection. •Three active wells were on the site at the time of inspection, five further wells were permitted for the expanded pad, and one well was proposed but never materialized.

2489204 Primary Facility 2016-01-26 Preoperation Inspection No Violations Noted On 1/26/2016, I performed a preoperation inspection at the Bernard Werner site in response to an operator request and made the following observations:

•Site perimeter controls were in place and functional. •Areas of exposed earth on site that were not being actively worked on were noted to have been temporarily stabilized. •An area near the corner of the impoundment may allow water to leave the LOD. It is recommended that the CFS be extended to meet the nearby culvert. This recommendation was accepted by the operator at the time of inspection and approved as a redline request. No violation. •A roadside ditch sloping towards the pad was not rock lined at the time of inspection, due to directionality being towards site it is being considered an intermediate (not perimeter control). Per the operator it is expected to be finished by the end of the day. No violation. •Multiple redline changes were requested and approved during the inspection including addition of CFS near the entrance and the addition of two

2515187 Primary Facility 2016-05-24 Follow-up Inspection No Violations Noted On 5/24/16, I performed a follow up inspection at the Bernard Werner site monitoring issues noted on 1/26/16 (eFACTS ID: 2489198) and made the following observations:

•A moderately eroded ATV path extends from access road off site, reported to be land owner created. No violation. •The bank of the diversion channel on the up slope side of the access road was largely barren; no prominent erosion damage was noted. The diversion channel was otherwise completed and functional. No violation, remediation recommended. •The cut slope above the well pad was stabilized but was still very sparsely vegetated at the time of inspection. No violation. •The vertical shafts of 8 wells had been drilled on site and were awaiting further drilling at the time of inspection. •Additional bare or sparse patches of vegetation were found on the north side of the site access road near the well pad, one the cut slop between the well pad and the small accessory pad, and between the small pad and the impoundment. •Redline changes app

2538828 Primary Facility 2016-11-18 Drilling/Alteration No Violations Noted Patterson-UTI Drilling Rig #277

Moved onto this well on 11/2/16 and resumed drilling at 5920 ft. KOP was at 5920 ft. EOB on the curve was at 7943 ft. MD (7540 ft. TVD). TD was at 16,493 ft. MD (7533 ft. TVD) on 11/10/16. The 5 ½” casing was set at 16,493 ft. The estimated TOC is at 4517 ft.

2627710 Primary Facility 2017-08-22 Routine/Complete Inspection No Violations Noted On 8/22/17 an RTNC inspection of the Bernard Werner well site was conducted. The following was observed:

>>The site appeared stable and in generally good condition.

>>10 wells were observed at the time of inspection.

>>A section of CFS was found near the impoundment in a well vegetated area that should either be maintained or removed.

2666235 Primary Facility 2017-11-28 Incident- Response to Accident or Event No Violations Noted On 11/28/17 an incident inspection of the Werner well site was conducted in response to a spill (CTS ID: 331105) reported on 11/23/17. The following was observed:

>>An area of disturbed earth near a juncture in the site access road was noted to be unstabilized at the time of inspection. No violation, remediation recommended.

>>The exact location of the spill was unable to be determined, operator contacts with detailed information were not available at the time of inspection. No violation, further information needed for determination.

2666561 Primary Facility 2017-12-01 Follow-up Inspection No Violations Noted On 12/1/17 an incident inspection of the Werner well site was conducted in response to a spill (CTS ID: 331105) reported on 11/23/17. The following was observed:

>>The initial report was of a truck rollover that resulted in an estimated spill of 20 gallons of oil to the roadside culvert. The spill was fully cleaned at the time of the initial inspection on 11/28/17 but the location of the spill was unable to be identified. Upon locating the site of the spill cleanup appears to be complete and without further impact. While this constitutes a violation of 25 Pa. Code 78.54 in the the operator failed to control fluids associated with well servicing it has been determined that the violation was immediately corrected.

>>The unstabilized disturbed area noted on 11/28/17 remained unstabilized at the time of inspection. Continued failure to provide temporary stabilization would constitute a violation under 25 Pa. Code 102.22(b)(1).

2667063 Primary Facility 2017-12-04 Follow-up Inspection No Violations Noted On 12/4/17 an FUI inspection was conducted in response to concerns noted during a prior inspection on 12/1/17. The following was noted:

>>The unstabilized area of the site noted during a prior inspection on 12/1/17 had been stabilized at the time of inspection. No violation.

>>A small area between a section of CFS near the road juncture and the drainage channel was not stabilized. CFS at this location was also noted to be damaged. Remediation is recommended, no violation.

2686030 Primary Facility 2018-01-23 Administrative/File Review No Violations Noted On 1/23/18 an administrative inspection related to the Werner Well site was conducted in response to a complaint (CTS ID: 325462). The operator reported the complainant's concerns of potential pollution of a spring used as a partial water supply. Direct contact with the complainant found that the water had a history of methane contamination but no new or ongoing evidence of contamination. Further investigation by the DEP was declined at this time.
2708176 Primary Facility 2018-03-14 Routine/Complete Inspection No Violations Noted Well has been completed and is now producing.
2708179 Primary Facility 2018-03-14 Routine/Complete Inspection No Violations Noted Well has been completed and is now producing.
2715894 Primary Facility 2018-04-06 Routine/Partial Inspection No Violations Noted On 4/6/18 a routine partial inspection of the Werner Well Site was conducted in response to an operator request for permit termination review of an adjacent site. The following was observed:

>>An area at the juncture of the access road and the access road of a nearby pipeline site was found to be unstabilized with partially constructed controls and early indications of increased erosion damage. No violation, stabilization in accordance with permit conditions is strongly recommended.

>>The adjacent Werner to Smith Pipeline was reported as unconstructed with regards to the permit termination request. Evidence of pipeline construction within the planned ROW was noted as related to a separate permit.

2725830 Primary Facility 2018-04-27 Follow-up Inspection No Violations Noted On 4/27/18 a follow up inspection of the Werner well site was conducted in response to issues first noted during a 4/6/18 routine partial inspection related to permit termination of an adjacent site. The following was observed:

>>The area noted in inspection report 2715873 as unstabilized and displaying increased erosion remained in much the same condition without surface stabilization. No indication of any work being conducted in the general area during the 21 days between inspections was found. This constitutes a violation of 25 Pa. Code § 102.22(b)(1) in that the operator failed to stabilize an area during any cessation of work in excess of four days.

2815108 Primary Facility 2018-12-13 Compliance Evaluation No Violations Noted On 12/13/18 a compliance evaluation inspection of the Werner Well Site was conducted in response to violations initially noted on 4/27/18. The following was observed:

> The unstabilized area of the site that was the subject of the violations was found to be fully vegetated and stabilized with site BMPs installed. An adjacent area of recent earth work was also stabilized. No further violations were found.

For data sources see[8]

References