37-125-27339

Well Details

Well ID: 37-125-27339
Loading map...
Country: United States
State: Pennsylvania
County: Washington
Municipality: Carroll Township
Operator Name: EQT PROD CO
Well Pad ID: 145213
Farm/Lease Name: R SMITH 592299
License Status:
Spud Date:
Permit Date: 2014-04-01
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 40.164756
Longitude: -79.944539

For data sources see[1][2][3]

Well History

Date Event
2014-04-01 New Permit Application
2014-04-24 Performed Spud Operation
2014-05-26 Drilling Completion
2014-09-01 Perforation
2014-09-01 Performed Stimulation
2016-03-11 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2014-09-01 2014-09-10 7,655 12,271,700 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 APB-1 FTS International Breaker Ammonium persulfate 7727-54-0 95 0.000152366 173.85
Hydrochloric Acid (15%) FTS International Acidizing Hydrochloric chloride 7647-01-0 15 0.0291269 33234
Chlorine Dioxide Solution-SVP-Pure Neptune Service Company Disinfectant or oxidizer Chlorine dioxide 10049-04-4 0.3 0.00001304 14.876
NE-100 FTS International Non-emulsifier Dodecylbenzenesulfonic acid 27176-87-0 5 0.00001665 19.002
2-Propanol 67-63-0 10 0.00003331 38.003
2-Butoxyethanol 111-76-2 10 0.00003331 38.003
FRW-900 FTS International Friction reducer Alkyl alcohol Proprietary 10 0.00860086 9813.63
Oxyalkylated alcohol A Proprietary 5 0.00430043 4906.81
Hydrotreated light distillate 64742-47-8 30 0.0258026 29440.9
Sand (Proppant) FTS International Proppant Silica Substrate 14808-60-7 100 9.90617 11,303,000.0
FE-100L FTS International Iron control Citric acid 77-92-9 55 0.000683511 779.89
CI-150 FTS International Acid corrosion inhibitor Quaternary ammonium compound Proprietary 10 0.00003620 41.308
Isopropanol 67-63-0 30 0.000108609 123.923
Organic amine resin salt Proprietary 30 0.000108609 123.923
Dimethylformamide 68-12-2 10 0.00003620 41.308
Aromatic aldehyde Proprietary 10 0.00003620 41.308
Ethylene glycol 107-21-1 30 0.000108609 123.923
HVG-1 FTS International Gelling agent Clay 14808-60-7 2 0.00024656 281.327
Guar gum 9000-30-0 50 0.00616401 7033.17
Petroleum distillate 64742-47-8 55 0.00678041 7736.48
Surfactant 68439-51-0 2 0.00024656 281.327
Water FTS International Carrier/Base Fluid Water 7732-18-5 100 89.7519 102,407,000.0
B-10 FTS International High pH Buffer Potassium carbonate 584-08-7 48 0.00500741 5713.48
Potassium hydroxide 1310-58-3 20 0.00208642 2380.62
Hydrochloric Acid (7.5%) FTS International Acidizing Hydrochloric chloride 7647-01-0 7.5 0.00226543 2584.86
FRW-600 FTS International Friction reducer Hydrotreated light distillate 64742-47-8 30 0.000695403 793.459
Ammonium acetate 631-61-8 6 0.000139081 158.692

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2014-09-01 0 0 0

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2014 EQT PROD CO 444,038.00 69 0.00 0 0.00 0
2015 EQT PROD CO 2,800,240.00 365 0.00 0 0.00 0
2016 EQT PROD CO 2,147,361.00 346 0.00 0 0.00 0
2017 EQT PROD CO 1,299,641.00 362 0.00 0 0.00 0
2018 EQT PROD CO 973,309.00 357 0.00 0 0.00 0
2019 EQT PROD CO 916,730.00 322 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2014 EQT PROD CO Drill Cuttings 1,121.66 Tons LANDFILL 100419
2014 EQT PROD CO Produced Fluid 10,600.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 EQT PROD CO Produced Fluid 100.00 Bbl INJECTION DISPOSAL WELL 34-009-23821
2014 EQT PROD CO Fracing Fluid Waste 26,350.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 EQT PROD CO Drilling Fluid Waste 760.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 EQT PROD CO Produced Fluid 114.00 Bbl LANDFILL SWF 1032-WV0109
2014 EQT PROD CO Drilling Fluid Waste 300.00 Bbl CENT WASTE TRT FAC NPDES EPA ID: 748-163
2014 EQT PROD CO Fracturing Fluid Waste 85.00 Tons LANDFILL 100277
2014 EQT PROD CO Drilling Fluid Waste 229.00 Bbl LANDFILL SWF 1032-WV0109
2014 EQT PROD CO Drilling Fluid Waste 300.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE EPA ID: 748-163
2014 EQT PROD CO Drilling Fluid Waste 414.00 Bbl INJECTION DISPOSAL WELL 34-009-23821
2014 EQT PROD CO Produced Fluid 190.00 Bbl INJECTION DISPOSAL WELL 34-157-25511
2014 EQT PROD CO Fracturing Fluid Waste 133.00 Tons LANDFILL SWF 1032-WV0109
2014 EQT PROD CO Produced Fluid 200.00 Bbl INJECTION DISPOSAL WELL 34-031-27177
2014 EQT PROD CO Fracing Fluid Waste 98.00 Bbl LANDFILL SWF 1032-WV0109
2015 EQT PROD CO Drilling Fluid Waste 130.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015 EQT PROD CO Fracing Fluid Waste 150.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015 EQT PROD CO Produced Fluid 1,100.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW005
2015 EQT PROD CO Fracturing Fluid Waste 25.00 Tons LANDFILL SWF 1032-WV0109
2015 EQT PROD CO Produced Fluid 422.00 Bbl INJECTION DISPOSAL WELL 34-157-25511
2015 EQT PROD CO Produced Fluid 80.00 Bbl INJECTION DISPOSAL WELL 34-059-24202
2015 EQT PROD CO Produced Fluid 14,639.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 EQT PROD CO Produced Fluid 4,988.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 EQT PROD CO Produced Fluid 330.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2016 EQT PROD CO Other Oil & Gas Wastes 2.78 Tons LANDFILL 100419
2016 EQT PROD CO Servicing Fluid 260.00 Tons REUSE OTHER THAN ROAD SPREADING
2016 EQT PROD CO Produced Fluid 274.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW005
2016 EQT PROD CO Produced Fluid 130.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2017 EQT PROD CO Produced Fluid 6.83 Bbl RESIDUAL WASTE PROCESSING FACILITY
2017 EQT PROD CO Produced Fluid 1,171.48 Bbl REUSE (AT WELL PAD)
2017 EQT PROD CO Produced Fluid 110.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2017 EQT PROD CO Produced Fluid 860.66 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017 EQT PROD CO Produced Fluid 38.32 Bbl INJECTION DISPOSAL WELL 34-031-27177
2018 EQT PROD CO Produced Fluid 407.38 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018 EQT PROD CO Other Oil & Gas Wastes 10.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW009
2018 EQT PROD CO Other Oil & Gas Wastes 10.45 Bbl RESIDUAL WASTE PROCESSING FACILITY
2018 EQT PROD CO Produced Fluid 52.44 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018 EQT PROD CO Other Oil & Gas Wastes 52.94 Bbl REUSE (AT WELL PAD)
2018 EQT PROD CO Other Oil & Gas Wastes 91.36 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018 EQT PROD CO Produced Fluid 275.64 Bbl REUSE (AT WELL PAD)
2018 EQT PROD CO Other Oil & Gas Wastes 10.45 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2019 EQT PROD CO Other Oil & Gas Wastes 5.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 EQT PROD CO Other Oil & Gas Wastes 40.00 Bbl RESIDUAL WASTE PROCESSING FACILITY
2019 EQT PROD CO Produced Fluid 1,247.74 Bbl REUSE (AT WELL PAD)
2019 EQT PROD CO Produced Fluid 15.35 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW010
2019 EQT PROD CO Other Oil & Gas Wastes 232.50 Bbl REUSE (AT WELL PAD)
2019 EQT PROD CO Produced Fluid 28.69 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 EQT PROD CO Produced Fluid 19.66 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2019 EQT PROD CO Produced Fluid 16.30 Bbl INJECTION DISPOSAL WELL 34-167-29543
2019 EQT PROD CO Produced Fluid 1.79 Bbl INJECTION DISPOSAL WELL 34-167-28462
2019 EQT PROD CO Other Oil & Gas Wastes 19.41 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2019 EQT PROD CO Produced Fluid 11.54 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2268586 Primary Facility 2014-05-06 Drilling/Alteration No Violations Noted EQT drilled a 26” cellar approximately 80 ft. for the R. Smith 592299 well on 4/25/2014.
2271127 Primary Facility 2014-05-13 Drilling/Alteration No Violations Noted Pioneer Rig 72 began drilling on the R. Smith 592299 well on 5/10/14.
2271860 Primary Facility 2014-05-19 Drilling/Alteration No Violations Noted Pioneer Rig 72
2274288 Primary Facility 2014-05-28 Drilling/Alteration No Violations Noted Pioneer Rig 72
2340248 Primary Facility 2015-01-30 Routine/Complete Inspection No Violations Noted Violations for todays inspection linked to site inspection 2340109 enforcement 319619
2343349 Primary Facility 2015-02-10 Routine/Complete Inspection No Violations Noted Well in production. Well in compliance with environmental regulations.
2350215 Primary Facility 2015-03-10 Routine/Complete Inspection No Violations Noted
2350356 Primary Facility 2015-02-24 Routine/Complete Inspection No Violations Noted
2361143 Primary Facility 2015-04-14 Routine/Complete Inspection No Violations Noted On April 14th 2015, I inspected the Robert Smith Pad in response to an NOT request and made the following observations:
2363378 Primary Facility 2015-02-10 Routine/Partial Inspection No Violations Noted On 2/10/15 took water samples from well (tap in garage) based on analysis code 946.
2363392 Primary Facility 2015-03-12 Administrative/File Review No Violations Noted On 3/12/15 administrative review of lab results with WQS Bryon Miller did not indicate that gas well activities have impacted the water supply at this time.
2402142 Primary Facility 2015-08-14 Compliance Evaluation No Violations Noted On 8/14/15, I inspected the Robert Smith site as a compliance evaluation inspection in response to the remediation report for a spill occurring on 1/31/15 and made the following observations:
2544062 Primary Facility 2016-09-14 Incident- Response to Accident or Event No Violations Noted On 9/14/16 I performed an incident response inspection at the Robert Smith Site in response to an operator reported spill (CTS ID: 322335) and made the following observations:

•On 9/6/16 EQT Corey Giles reported a spill of 100 gallons of produced fluids to the well pad. The spill was forwarded to the WQS on 9/14/16. This constitutes a violation of 25 Pa. Code § 78.57(a) and 25 Pa. Code § 78.54 for failing to control brine and other fluids resulting in discharge to the ground and failure to prevent pollution to the Waters of the Commonwealth. •The spill was cleaned up at the time of inspection with the only observed indicator of the spill location being an area of new gravel on the pad near the production units. No violation. •Well drilling was ongoing at the time of inspection. •During general pad inspection it was noted that multiple production tanks had orange streaking running down their sides from the top of the tanks. The gravel of the pad surface near the containment displayed matching orange stai

2614153 Primary Facility 2017-05-05 Incident- Response to Accident or Event In Compliance with Policy On 5/5/17 an INCDT inspection of the R. Smith well site was conducted in response to CTS ID: 326715. The following was observed:

>> Site was undergoing fracking at time of inspection.

>>The spill in question involved roughly 10 gallons of produced water being sprayed from from an overfilled accessory tank on the pad. Affected pad materials were collected and placed in a waste box on pad for disposal. No violation, site appears to be in compliance with policy.

>>Streaking was again noted on the outside of multiple production tanks similar to streaking noted in previous inspections.

2660131 Primary Facility 2017-11-09 Routine/Complete Inspection No Violations Noted On 11/10/17 a routine complete inspection of the R. Smith well site was conducted in response to notification additional drilling on site. The following was observed:

>>A box tank was found near the impoundment with no containment. Remediation recommended, no violation.

>>A new top soil stock pile was noted on site. It was stabilized with straw at the time of inspection.

>>The soil stock pile was noted to not have any functional controls below it other than an adequate vegetated strip. Decomposed CFS should be removed, repaired, or replaced. No violation.

>>Drilling was ongoing at the site at the time of inspection.

2691654 Primary Facility 2018-02-02 Routine/Complete Inspection No Violations Noted Well has been fracked and is producing.
2705450 Primary Facility 2018-03-13 Routine/Partial Inspection No Violations Noted On 3/14/18 a routine complete inspection of the R. Smith Well Site was conducted in response to a notification of proposed construction activity on the pad. The following was observed:

>>The site was in a high activity phase at the time of inspection drilling appeared to be completed and the site was in apparent transition to post drilling activities. No drilling rig was present on site at the time of inspection.

>>Construction of a proposed AST had not begun at the time of inspection.

>>Many water trucks were present on site in association with the attached impoundment.

2737818 Primary Facility 2018-05-16 Incident- Response to Accident or Event No Violations Noted On 5/16/18 an incident inspection of the R. Smith well site was conducted in response to a spill reported by the operator on 5/14/18. The following was observed:

>>The operator reported that roughly 35 gallons of mixed rain water and produced water was spilled to the pad when a section of containment was moved without being drained first. Fluids were spread over a large area of the pad along the area in front of the production units per discussion with Mike Cromley at the time of inspection. This does constitute a violation of 25 Pa. Code § 78.54 and 25 Pa. Code § 78.57(a) in that the operator failed to control regulated materials in a manner that prevents prevents pollution to the ground or Waters of the Commonwealth however, the violation is regarded as immediately corrected.

>>Site inspection found no residual evidence of the spill. The operator reported that all visibly impacted gravel from the spill area had been removed (roughly two clamshell dumpsters).

2747160 Primary Facility 2018-06-29 Routine/Partial Inspection No Violations Noted On 6/29/18 a routine partial inspection of the R. Smith Well Site was conducted in response to concerns about runoff raised by a nearby resident. The following was observed:

>>An unstabilized soil pile near the corner of the pad with a newly improved drain. Controls below the pile were absent though the vegetation was sufficient. No violation, remediation recommended.

>>Another only partially stabilized soil pile with no controls below the pile was located along the accessory pad access road. No controls beyond vegetation were present below the soil pile. No violation, monitoring recommended.

>>An AST was present on the accessory pad.

>>The pad was active at the time of inspection with drilling preparations ongoing. A sound wall was present around the pad perimeter.

2761850 Primary Facility 2018-08-02 Routine/Complete Inspection No Violations Noted On 8/2/18 a complaint response inspection was conducted of the R Smith well site in response to reported concerns of inappropriate drainage from the pad. WQSS John Carson accompanied. The following was observed:

>>A top soil pile on the access road to the accessory pad remained lacking vegetation and with spotty temporary stabilization. The vegetative strip below remains in good condition. Remediation recommended, no violation.

>>Emptying partially filled containment is encouraged to aid in identifying any possible leaks. No violation.

>>No evidence of excessive or unpermitted runoff from the pad was found.

>>Box in containment appears to be collecting emergency blowdown. If so it should be properly marked. No violation.

For data sources see[9]