X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-125-24243

Well Details

Well ID: 37-125-24243
Loading map...
Country: United States
State: Pennsylvania
County: Washington
Municipality: Carroll Township
Operator Name: EQT PROD CO
Well Pad ID: 145213
Farm/Lease Name: ROBERT SMITH 3H
License Status:
Spud Date:
Permit Date: 2010-07-19
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 40.164750
Longitude: -79.944472

For data sources see[1][2][3]

Well History

Date Event
2010-07-19 New Permit Application
2010-10-13 Performed Spud Operation
2010-11-13 Drilling Completion
2011-07-15 Perforation
2011-07-15 Performed Stimulation
2013-06-06 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2011-07-12 2011-07-12 7,627 5,965,050

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 ACID, HYDROCHLORIC, 15 PCT Weatherford Acid Water 7732-18-5 85.00 0.54
Hydrochloric acid 7647-01-0 15.00 0.09
Inhibitor - WAI-251LC Weatherford Corrosion Inhibitor Isopropanol 67-63-0 7.00 0.00002000
2-Butoxyethanol 111-76-2 5.00 0.00001000
N,N-Dimethylformamide 68-12-2 30.00 0.00008000
1-Octanol 111-87-5 7.00 0.00002000
Proprietary 13.00 0.00003000
1-Decanol 112-30-1 7.00 0.00002000
Ethylene glycol 107-21-1 40.00 0.00011000
EC6629 (010) Nalco Scale Inhibitor No Hazardous Components 0.00
WBK-133, Breaker Weatherford Breaker Peroxydisulfuric acid, diammonium salt 7727-54-0 100.00 0.00571000
WFR-61LA Weatherford Friction Reducer Ethoxylated C12-16 alcohols 68551-12-2 7.00 0.00796000
Ammonium chloride 12125-02-9 7.00 0.00796000
Distillates, petroleum, hydrotreated light 64742-47-8 40.00 0.04
Sodium chloride 7647-14-5 10.00 0.01
Fresh Water Carrier/Base Fluid 79.65
WGA-15L Weatherford Gelling Agent Proprietary Polymer 60.00 0.01
Distillates, petroleum, hydrotreated light 64742-47-8 60.00 0.01
Recycled Produced Water Carrier/Base Fluid 9.44
Sand (Proppant) Proppant 10.07
WBK-134 Weatherford Breaker Peroxydisulfuric acid, diammonium salt 7727-54-0 100.00 0.00482000
Quartz 14808-60-7 10.00 0.00048000
Iron Control - WIC-641L Weatherford Iron Control Agent Citric acid 77-92-9 50.00 0.00079000
EC6110A Nalco Antibacterial Agent Glutaraldehyde 111-30-8 60.00 0.01
Ethanol 64-17-5 5.00 0.00159000
Quaternary Ammonium Compounds 10.00 0.00317000

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2011-07-15 0 0 0

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 CHESAPEAKE APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2011 CHESAPEAKE APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2012 CHESAPEAKE APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2013 EQT PROD CO 162,226.00 27 0.00 0 0.00 0
2014 EQT PROD CO 1,382,383.00 304 0.00 0 0.00 0
2015 EQT PROD CO 944,242.00 350 0.00 0 0.00 0
2016 EQT PROD CO 564,715.00 359 0.00 0 0.00 0
2017 EQT PROD CO 380,021.00 362 0.00 0 0.00 0
2018 EQT PROD CO 265,965.00 361 0.00 0 0.00 0
2019 EQT PROD CO 277,776.00 289 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2011 CHESAPEAKE APPALACHIA LLC Fracing Fluid Waste 190.00 Bbl INJECTION DISPOSAL WELL 34-121-23995
2011 CHESAPEAKE APPALACHIA LLC Fracing Fluid Waste 980.00 Bbl INJECTION DISPOSAL WELL 34-121-23390
2011 CHESAPEAKE APPALACHIA LLC Fracing Fluid Waste 816.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2011 CHESAPEAKE APPALACHIA LLC Fracing Fluid Waste 300.00 Bbl INJECTION DISPOSAL WELL 2D0610317
2011 CHESAPEAKE APPALACHIA LLC Fracing Fluid Waste 9,715.00 Bbl REUSE OTHER THAN ROAD SPREADING
2011 CHESAPEAKE APPALACHIA LLC Fracing Fluid Waste 605.00 Bbl INJECTION DISPOSAL WELL 34-133-21076
2012 CHESAPEAKE APPALACHIA LLC Produced Fluid 185.00 Bbl INJECTION DISPOSAL WELL 34-115-21896
2012 CHESAPEAKE APPALACHIA LLC Produced Fluid 210.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 EQT PROD CO Produced Fluid 605.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 EQT PROD CO Fracing Fluid Waste 114.00 Bbl INJECTION DISPOSAL WELL 34-167-28462
2013 EQT PROD CO Produced Fluid 740.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE EPA ID: 748-163
2013 EQT PROD CO Drilling Fluid Waste 115.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 EQT PROD CO Fracing Fluid Waste 1,350.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 EQT PROD CO Fracing Fluid Waste 130.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE EPA ID: 748-163
2013 EQT PROD CO Produced Fluid 740.00 Bbl CENT WASTE TRT FAC NPDES EPA ID: 748-163
2013 EQT PROD CO Fracing Fluid Waste 130.00 Bbl CENT WASTE TRT FAC NPDES EPA ID: 748-163
2014 EQT PROD CO Produced Fluid 3,579.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 EQT PROD CO Fracing Fluid Waste 740.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 EQT PROD CO Drilling Fluid Waste 1,563.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 EQT PROD CO Drilling Fluid Waste 100.00 Bbl LANDFILL SWF 1032-WV0109
2015 EQT PROD CO Drilling Fluid Waste 110.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015 EQT PROD CO Fracing Fluid Waste 220.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015 EQT PROD CO Produced Fluid 70.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2015 EQT PROD CO Produced Fluid 220.00 Bbl INJECTION DISPOSAL WELL 34-157-25511
2015 EQT PROD CO Produced Fluid 1,210.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW005
2015 EQT PROD CO Produced Fluid 8,451.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 EQT PROD CO Other Oil & Gas Wastes 186.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 EQT PROD CO Produced Fluid 10,010.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 EQT PROD CO Produced Fluid 358.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2016 EQT PROD CO Produced Fluid 940.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW005
2016 EQT PROD CO Produced Fluid 168.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2017 EQT PROD CO Produced Fluid 2.74 Bbl RESIDUAL WASTE PROCESSING FACILITY
2017 EQT PROD CO Other Oil & Gas Wastes 320.00 Bbl REUSE (AT WELL PAD)
2017 EQT PROD CO Produced Fluid 1,660.04 Bbl REUSE (AT WELL PAD)
2017 EQT PROD CO Other Oil & Gas Wastes 192.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017 EQT PROD CO Produced Fluid 207.19 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017 EQT PROD CO Produced Fluid 15.37 Bbl INJECTION DISPOSAL WELL 34-031-27177
2018 EQT PROD CO Other Oil & Gas Wastes 10.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW009
2018 EQT PROD CO Other Oil & Gas Wastes 10.45 Bbl RESIDUAL WASTE PROCESSING FACILITY
2018 EQT PROD CO Produced Fluid 12.25 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018 EQT PROD CO Produced Fluid 111.67 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018 EQT PROD CO Other Oil & Gas Wastes 174.99 Bbl REUSE (AT WELL PAD)
2018 EQT PROD CO Other Oil & Gas Wastes 91.36 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018 EQT PROD CO Produced Fluid 120.70 Bbl REUSE (AT WELL PAD)
2018 EQT PROD CO Other Oil & Gas Wastes 10.45 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2019 EQT PROD CO Produced Fluid 5.90 Bbl INJECTION DISPOSAL WELL 34-167-29543
2019 EQT PROD CO Produced Fluid 8.66 Bbl RESIDUAL WASTE PROCESSING FACILITY
2019 EQT PROD CO Produced Fluid 207.19 Bbl REUSE (AT WELL PAD)
2019 EQT PROD CO Produced Fluid 4.20 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW010
2019 EQT PROD CO Produced Fluid 10.16 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 EQT PROD CO Produced Fluid 0.61 Bbl INJECTION DISPOSAL WELL 34-167-28462
2019 EQT PROD CO Other Oil & Gas Wastes 24.41 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2019 EQT PROD CO Other Oil & Gas Wastes 247.95 Bbl REUSE (AT WELL PAD)
2019 EQT PROD CO Produced Fluid 2.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2019 EQT PROD CO Produced Fluid 6.50 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1922446 Primary Facility 2010-09-01 Routine/Complete Inspection No Violations Noted
1934201 Primary Facility 2010-10-14 Drilling/Alteration No Violations Noted Randsom auger - Well spud, Nomak 243 rigging up to begin drilling operation, closed loop, site and location good.
1934222 Primary Facility 2010-10-20 Drilling/Alteration No Violations Noted Nomak 243 - Rigging up, putting BHA together, site and location good, closed loop
1934223 Primary Facility 2010-10-27 Drilling/Alteration No Violations Noted Nomak 243 - TD@1280,drilling ahead, no return on cement, , grouted back side. Site and location good, closed loop
1934224 Primary Facility 2010-11-09 Drilling/Alteration No Violations Noted Nomak 243 - TD@9031, tripping outto change gamma tool, returns on 9.58, Site and location good, closed loop
2078352 Primary Facility 2012-06-18 Routine/Complete Inspection No Violations Noted
2350214 Primary Facility 2015-03-10 Routine/Complete Inspection No Violations Noted
2402143 Primary Facility 2015-08-14 Compliance Evaluation No Violations Noted On 8/14/15, I inspected the Robert Smith site as a compliance evaluation inspection in response to the remediation report for a spill occurring on 1/31/15 and made the following observations:
2544063 Primary Facility 2016-09-14 Incident- Response to Accident or Event No Violations Noted On 9/14/16 I performed an incident response inspection at the Robert Smith Site in response to an operator reported spill (CTS ID: 322335) and made the following observations:

•On 9/6/16 EQT Corey Giles reported a spill of 100 gallons of produced fluids to the well pad. The spill was forwarded to the WQS on 9/14/16. This constitutes a violation of 25 Pa. Code § 78.57(a) and 25 Pa. Code § 78.54 for failing to control brine and other fluids resulting in discharge to the ground and failure to prevent pollution to the Waters of the Commonwealth. •The spill was cleaned up at the time of inspection with the only observed indicator of the spill location being an area of new gravel on the pad near the production units. No violation. •Well drilling was ongoing at the time of inspection. •During general pad inspection it was noted that multiple production tanks had orange streaking running down their sides from the top of the tanks. The gravel of the pad surface near the containment displayed matching orange stai

2614133 Primary Facility 2017-05-05 Incident- Response to Accident or Event In Compliance with Policy On 5/5/17 an INCDT inspection of the R. Smith well site was conducted in response to CTS ID: 326715. The following was observed:

>> Site was undergoing fracking at time of inspection.

>>The spill in question involved roughly 10 gallons of produced water being sprayed from from an overfilled accessory tank on the pad. Affected pad materials were collected and placed in a waste box on pad for disposal. No violation, site appears to be in compliance with policy.

>>Streaking was again noted on the outside of multiple production tanks similar to streaking noted in previous inspections.

2660103 Primary Facility 2017-11-09 Routine/Complete Inspection No Violations Noted On 11/10/17 a routine complete inspection of the R. Smith well site was conducted in response to notification additional drilling on site. The following was observed:

>>A box tank was found near the impoundment with no containment. Remediation recommended, no violation.

>>A new top soil stock pile was noted on site. It was stabilized with straw at the time of inspection.

>>The soil stock pile was noted to not have any functional controls below it other than an adequate vegetated strip. Decomposed CFS should be removed, repaired, or replaced. No violation.

>>Drilling was ongoing at the site at the time of inspection.

2691667 Primary Facility 2018-02-02 Routine/Complete Inspection No Violations Noted Well has been fracked and is producing.
2705383 Primary Facility 2018-03-13 Routine/Partial Inspection No Violations Noted On 3/14/18 a routine complete inspection of the R. Smith Well Site was conducted in response to a notification of proposed construction activity on the pad. The following was observed:

>>The site was in a high activity phase at the time of inspection drilling appeared to be completed and the site was in apparent transition to post drilling activities. No drilling rig was present on site at the time of inspection.

>>Construction of a proposed AST had not begun at the time of inspection.

>>Many water trucks were present on site in association with the attached impoundment.

2730981 Primary Facility 2018-05-16 Incident- Response to Accident or Event No Violations Noted On 5/16/18 an incident inspection of the R. Smith well site was conducted in response to a spill reported by the operator on 5/14/18. The following was observed:

>>The operator reported that roughly 35 gallons of mixed rain water and produced water was spilled to the pad when a section of containment was moved without being drained first. Fluids were spread over a large area of the pad along the area in front of the production units per discussion with Mike Cromley at the time of inspection. This does constitute a violation of 25 Pa. Code § 78.54 and 25 Pa. Code § 78.57(a) in that the operator failed to control regulated materials in a manner that prevents prevents pollution to the ground or Waters of the Commonwealth however, the violation is regarded as immediately corrected.

>>Site inspection found no residual evidence of the spill. The operator reported that all visibly impacted gravel from the spill area had been removed (roughly two clamshell dumpsters).

2747124 Primary Facility 2018-06-29 Routine/Partial Inspection No Violations Noted On 6/29/18 a routine partial inspection of the R. Smith Well Site was conducted in response to concerns about runoff raised by a nearby resident. The following was observed:

>>An unstabilized soil pile near the corner of the pad with a newly improved drain. Controls below the pile were absent though the vegetation was sufficient. No violation, remediation recommended.

>>Another only partially stabilized soil pile with no controls below the pile was located along the accessory pad access road. No controls beyond vegetation were present below the soil pile. No violation, monitoring recommended.

>>An AST was present on the accessory pad.

>>The pad was active at the time of inspection with drilling preparations ongoing. A sound wall was present around the pad perimeter.

2761313 Primary Facility 2018-08-02 Routine/Complete Inspection No Violations Noted On 8/2/18 a complaint response inspection was conducted of the R Smith well site in response to reported concerns of inappropriate drainage from the pad. WQSS John Carson accompanied. The following was observed:

>>A top soil pile on the access road to the accessory pad remained lacking vegetation and with spotty temporary stabilization. The vegetative strip below remains in good condition. Remediation recommended, no violation.

>>Emptying partially filled containment is encouraged to aid in identifying any possible leaks. No violation.

>>No evidence of excessive or unpermitted runoff from the pad was found.

>>Box in containment appears to be collecting emergency blowdown. If so it should be properly marked. No violation.

For data sources see[9]

References