Well History

Date Event
2010-05-11 New Permit Application
2011-02-14 Performed Spud Operation
2011-04-28 Drilling Completion
2012-03-27 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2011-06-16 2011-06-16 7,567 3,418,249

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 GBW-30 Halliburton Enzyme Breaker Hemicellulase Enzyme 9012-54-8 15.0 0.0001
FR-66 Halliburton Friction Reducer Hydrotreated light petroleum distillate 64742-47-8 30.0 0.0281
BE-9 Halliburton Biocide Tributyl tetradecyl phosphonium chloride 81741-28-8 10.0 0.0041
BA-40L Halliburton Buffer Potassium carbonate 584-08-7 60.0 0.0079
LP-65 Halliburton Scale Inhibitor Ammonium chloride 12125-02-9 10.0 0.0028
HCl Halliburton Corrosion Inhibitor Propargyl Alcohol 107-19-7 10.0 0.0002
Hydrochloric Acid 7647-01-0 28.0 0.1224
Methanol 67-56-1 60.0 0.0012
SP Breaker Halliburton Oxidizing Breaker Sodium Persulfate 7775-27-1 100.0 0.0004
WG-36 Halliburton Gelling Agent Guar Gum 9000-30-0 100.0 0.0256
Naptha, hydrotreated heavy 64742-48-9 None None
HCl Halliburton 15 HCl Acid

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 EQT PROD CO 0.00 0 0.00 0 0.00 0
2011 EQT PROD CO 0.00 0 0.00 0 0.00 0
2012 EQT PROD CO 2,044,853.00 308 0.00 0 0.00 0
2013 EQT PROD CO 965,866.00 365 0.00 0 0.00 0
2014 EQT PROD CO 303,687.00 304 0.00 0 0.00 0
2015 EQT PROD CO 190,106.00 294 0.00 0 0.00 0
2016 EQT PROD CO 379,682.00 354 0.00 0 0.00 0
2017 EQT PROD CO 207,646.00 365 0.00 0 0.00 0
2018 EQT PROD CO 147,893.00 360 0.00 0 0.00 0
2019 EQT PROD CO 19,216.00 34 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2011 EQT PROD CO Drilling Fluid Waste 438.00 Bbl REUSE OTHER THAN ROAD SPREADING
2011 EQT PROD CO Fracing Fluid Waste 32,004.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 EQT PROD CO Produced Fluid 100.00 Bbl INJECTION DISPOSAL WELL 34-083-24137
2012 EQT PROD CO Produced Fluid 4,024.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 EQT PROD CO Produced Fluid 112.00 Bbl INJECTION DISPOSAL WELL 34-121-23995
2012 EQT PROD CO Produced Fluid 114.00 Bbl INJECTION DISPOSAL WELL 34-167-28462
2012 EQT PROD CO Fracing Fluid Waste 17,810.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 EQT PROD CO Produced Fluid 691.00 Bbl INJECTION DISPOSAL WELL 34-167-28466
2012 EQT PROD CO Produced Fluid 951.00 Bbl INJECTION DISPOSAL WELL 34-167-29577
2012 EQT PROD CO Produced Fluid 100.00 Bbl INJECTION DISPOSAL WELL 34-059-24067
2013 EQT PROD CO Produced Fluid 8,021.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 EQT PROD CO Drilling Fluid Waste 340.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 EQT PROD CO Produced Fluid 30.00 Bbl INJECTION DISPOSAL WELL 34-059-24202
2014 EQT PROD CO Drilling Fluid Waste 155.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 EQT PROD CO Fracing Fluid Waste 5.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 EQT PROD CO Produced Fluid 1,055.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015 EQT PROD CO Fracing Fluid Waste 220.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015 EQT PROD CO Produced Fluid 110.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW005
2015 EQT PROD CO Produced Fluid 470.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 EQT PROD CO Produced Fluid 676.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 EQT PROD CO Other Oil & Gas Wastes 150.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2016 EQT PROD CO Produced Fluid 130.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017 EQT PROD CO Other Oil & Gas Wastes 460.00 Bbl REUSE (AT WELL PAD)
2017 EQT PROD CO Produced Fluid 470.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2017 EQT PROD CO Other Oil & Gas Wastes 100.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017 EQT PROD CO Produced Fluid 886.44 Bbl REUSE (AT WELL PAD)
2018 EQT PROD CO Other Oil & Gas Wastes 138.67 Bbl REUSE (AT WELL PAD)
2018 EQT PROD CO Produced Fluid 59.90 Bbl REUSE (AT WELL PAD)
2018 EQT PROD CO Other Oil & Gas Wastes 146.29 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018 EQT PROD CO Other Oil & Gas Wastes 4.62 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2019 EQT PROD CO Other Oil & Gas Wastes 9.23 Bbl RESIDUAL WASTE PROCESSING FACILITY
2019 EQT PROD CO Other Oil & Gas Wastes 8.46 Bbl SURFACE IMPOUNDMENT 95-7-37312-19
2019 EQT PROD CO Synthetic Liner Materials 2.10 Tons LANDFILL 100277
2019 EQT PROD CO Produced Fluid 0.02 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 EQT PROD CO Other Oil & Gas Wastes 489.59 Bbl REUSE (AT WELL PAD)
2019 EQT PROD CO Other Oil & Gas Wastes 517.54 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 EQT PROD CO Produced Fluid 38.24 Bbl REUSE (AT WELL PAD)

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1953514 Primary Facility 2011-02-16 Drilling/Alteration No Violations Noted Well spudded - Site still under construction, E&S in place, large impoundment under construction,
2137755 Primary Facility 2013-01-09 Drilling/Alteration No Violations Noted
2513608 Primary Facility 2016-02-05 Complaint Inspection No Violations Noted On 2/5/16, I performed an incident inspection at the Kevech pad in response to a complaint concerning the site and made the following observations:

•Per the complainant:

    -The pad was built ten feet higher than permitted in order to not breach a coal seam which resulted in the cut slopes of the pad being steeper than permitted.
    -Multiple other pad features were suspected to be improperly constructed and maintained.
    -Concerns were also voiced about the grading and maintenance of the site access road.

•Pad elevation was measured to be 1080-1094 feet above sea level via multiple GPS devices, permitted pad height is 1085. •Site vegetation was noted to be sparse in areas, particularly north and east of the pad as well as on the southern and western cut slopes. •Badly damaged and partially destroyed remnants of super silt fence were found north and east of the pad. The filter fabric was entirely removed with pieces scattered around the surrounding area, the chain link fencing was also pulled from th

2523975 Primary Facility 2016-04-25 Follow-up Inspection No Violations Noted On 4/25/16, I performed a follow up inspection of the Kevech site accompanied by DEP engineer Emmanuel Nwaobilo in response to complaint 317639 from 2/3/16 (initial inspection took place on 2/5/16) and made the following observations:

•Per DEP engineer Emmanuel Nwaobilo the site’s contours and elevation appeared to be built to permitted plan specification. No violation. •Several heavily vegetated soil piles noted around the base of the pad not found in site plans were added as minor modifications and redlined into plans. No violation. •A corrugated drain pipe was found leading from just below the south east corner of the pad down to the vegetated channel at the bottom of the slope. Erosion channels were found in two separate locations along this pipe. No violation, remediation recommended. •A moderate erosion channel was found entering a ponded area of the diversion channel. •The operator has noted that a number of minor modifications had previously been made and accepted by DEP personnel but documentati

2609262 Primary Facility 2017-06-08 Complaint Inspection No Violations Noted On 6/8/17 an RTNC inspection of the Kevech well site and impoundment in response to a report of waste water being dumped in the freshwater impoundment. The following was observed:

>>No evidence was found at the impoundment of improper dumping.

>>Live fish were seen swimming in the impoundment indicating water remains uncontaminated.

>>The Kevech pad was being used as a staging point for the nearby Harold Haywood pad at the time of inspection.

2728646 Primary Facility 2018-05-10 Routine/Complete Inspection No Violations Noted This well has been completed and is producing. Well site appears to be well maintained. Along with 7 producing wells 6 new wells are being spud.
2742924 Primary Facility 2018-05-09 Routine/Complete Inspection No Violations Noted On 5/9/18 a routine partial inspection of the Kevech pad was conducted in response to drilling notifications and reports of significant activity at the site. The following was observed:

>>Construction of an AST pad was being conducted at the time of inspection. Multiple sections of CFS located around the construction area were noted to be poorly installed leaving gaps underneath or between sections. No violation, immediate remediation is encouraged due to heavy storms predicted for the area.

>>Large amounts of accumulated clay dust on the access road between the area of the new construction and the existing pad may present a safety hazard when wet as well as increased risk of sedimentation in runoff.

>>At the time of inspection operator personnel reported initial cement work had just been completed prior to cellar installation.

2756447 Primary Facility 2018-05-24 Follow-up Inspection No Violations Noted On 5/24/18 a follow up inspection of the Kevech pad was conducted in relation to issues noted in a previous inspection. The following was observed:

>>Deficiencies in implementation of site BMPs had been addressed and satisfactorily remedied. No further concerns were found.

>>Construction of site accessory areas was ongoing at the time of inspection.

>>A section of redundant silt fence was noted to be constructed along an exposed fill slope above the access road, consultation with EQT's Jason Tyler indicated that the fence had been put in place to catch "clumpies". The fence did not change function or flow of water on site. No violation.

2757088 Primary Facility 2018-07-26 Drilling/Alteration No Violations Noted On 7/26/18 a routine complete inspection was conducted of the Kevech well site. The following was observed:

>>A large soil stockpile near the impoundment area of the site was lacking stabilization and appeared to be suffering minor erosion damage in the area used to access the pile. No controls directly down gradient from the access could allow runoff and material to enter the access road and leave the site. Remediation strongly encouraged.

>>Substantial sediment was found accumulated in the collection channel between the large soil stockpile and main access road. Any runoff would likely carry sediment into the pictured under road culvert and into the vegetated strip on the side of the road. Compromised CFS with excess sediment overtopping the control was found directly up gradient along the channel. It is likely the source of the the accumulated sediment. Remediation recommended.

>>Cleanup from drilling activities were ongoing at the time of inspection.

>>Black mud in containment where panels w

2757126 Primary Facility 2018-07-27 Follow-up Inspection No Violations Noted On 7/27/18 a follow up inspection of the Kevech well site was conducted in response to issues noted during a previous inspection. The following was observed:

>>The access point to the large soil stock pile was being stabilized at the time of inspection.

>>CFS between the stock pile and the access road had been cleaned and repaired with added surface matting added above it.

>>The production fluids remained in the containment unit but spilled fluids and contaminated pad materials had been removed.

2853243 Primary Facility 2019-03-13 Routine/Complete Inspection No Violations Noted Well appears to be well maintained. Well is temporarily shut in due to low pressure.

For data sources see[8]