37-125-22082

Well Details

Well ID: 37-125-22082
Loading map...
Country: United States
State: Pennsylvania
County: Washington
Municipality: Donegal Township
Operator Name: BELDEN & BLAKE CORP
Well Pad ID:
Farm/Lease Name: FAIRGROUND UNIT 1
License Status: PLUGGED & ABANDONED
Spud Date:
Permit Date: 2003-05-28
Well Type: GAS
Unconventional Well: N
Configuration: Vertical Well
Conservation: No
Latitude: 40.110953
Longitude: -80.511997

For data sources see[1][2][3]

Well History

Date Event
2003-05-28 New Permit Application
2003-06-04 Performed Spud Operation
2003-08-08 Drilling Completion
2003-09-19 Perforation
2003-09-21 Performed Stimulation
2003-10-31 Drilling Completion
2004-02-02 NEWLY DRILLED
2004-05-19 FULLY PLUGGED

For data sources see[4]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2003-09-21 0 0 0

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2003 BELDEN & BLAKE CORP 0.00 0 0.00 0 0.00 0
2009 BELDEN & BLAKE CORP 0.00 0 0.00 0 0.00 0
2010 BELDEN & BLAKE CORP 0.00 0 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2003 BELDEN & BLAKE CORP Drilling 1,563.00 Bbl Brine or Industrial Waste Treatment Plt PA0102784
2003 BELDEN & BLAKE CORP Drilling 31,755.00 Bbl Road Spreading
2003 BELDEN & BLAKE CORP Fracking Fluid 1,516.00 Bbl Road Spreading

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1243847 Primary Facility 2003-06-12 Routine/Complete Inspection No Violations Noted Bench is cut & ditched, trap dug for sed. Three sed. fence barriers are set. Loggable trees are cut & piled. Site has previous storm sewer installation. Gravel access is good to the road. Pit is lined. Patterson Drilling Co., Snyder, Texas is the driller.
1250262 Primary Facility 2003-07-07 Routine/Complete Inspection No Violations Noted Rig up, pits lined, work continuing. Disturbed areas are seeded & germinating grass for stability. Access is graded & stabilized. ID/plan at entrance.
1261236 Primary Facility 2003-08-14 Routine/Complete Inspection No Violations Noted Rig here - lowered, haybales stacked, wellhead area work continuing, +/- 7 brine, frac, and drilling mud tanks here, containment pit open and containing fluids and cuttings. Deisel fuel tank here in use. Perimeter disturbed areas grassed over. Final restoration not begun at this time.
1277289 Primary Facility 2003-10-10 Routine/Complete Inspection No Violations Noted Site ID/plan here. Four frac tanks on site & some pipe racks. There is one large, open, lined pit , the original cutting pit.. Location marker appears to show a new hole location 30 or 40 yards south of first hole. Original hole is planked overtop to possibly to pull & plug at later date with other heavy equip. coming. Grading done on perimeter for restoration, more bench work drilling probable at bench at later date.
1308052 Primary Facility 2004-02-12 Routine/Complete Inspection No Violations Noted First well is plugged & annulus area cdovered. second location, same bench, shows casing of well. Pit is open & lined. Union Drilling has equip. stowed below bench including a floded, parked rig w/much other equip.
1321034 Primary Facility 2003-07-03 Drilling/Alteration No Violations Noted drilling ahead
1321035 Primary Facility 2003-07-02 Drilling/Alteration No Violations Noted drilling ahead
1321037 Primary Facility 2003-06-23 Drilling/Alteration No Violations Noted drilling ahead
1321372 Primary Facility 2004-03-22 Bond Release No Violations Noted Wells are plugged and to be left in area of open parking for the fairgrounds. Conductor pipes monuments to be level to the parking lot surface. Field check reveals vent pipes w/ID at monuments ( perfectly accepatable). Some slip repair needed and revegetation on the whole. Will recheck at later date for final bond release inspection.

For data sources see[8]