37-125-20166

Well Details

Well ID: 37-125-20166
Loading map...
Country: United States
State: Pennsylvania
County: Washington
Municipality: South Strabane Township
Operator Name: EDWARD M MAZUR
Well Pad ID:
Farm/Lease Name: ANGELO & PHILLIP FALCONI(PGH CONSOLI A1
License Status: ACTIVE
Spud Date:
Permit Date: 1967-03-16
Well Type: GAS
Unconventional Well: N
Configuration: Vertical Well
Conservation: No
Latitude: 40.209425
Longitude: -80.218144

For data sources see[1][2][3]

Well History

Date Event
1967-03-16 New Permit Application
1967-04-12 Performed Spud Operation
1967-05-24 Drilling Completion
1967-10-12 Perforation
1967-10-12 Performed Stimulation
1967-11-03 NEWLY DRILLED

For data sources see[4]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
1967-10-12 0 0 0

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2014 EDWARD M MAZUR 100.00 365 0.00 0 0.00 0

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2498062 Primary Facility 2016-06-27 Routine/Complete Inspection No Adverse Event or Action Reported Wellhead is situated ~100 feet from Fischer Road and ~35 feet from driveway in a level hayfield. Well has 15" conductor casing open to a depth of ~8-10 feet, 8 1/4" surface casing rusted off at same 8-10 level, with a collar and small section of casing roped to wellhead, 4" production casing free-standing in 8 1/4", topped w/ a tubinghead, w/ one port plumbed w/ Balon valve (closed), 2 3/8" tubing topped w/ Balon valve (open) and gauge reading 145#. Well is gassing from 8-10 foot level.
2511826 Primary Facility 2016-07-07 Routine/Partial Inspection No Adverse Event or Action Reported Revisited site to see if gas leak from well had changed - no, same as first visit. Gas can be heard bubbling at depth.
2624336 Primary Facility 2017-08-04 Routine/Partial Inspection No Viols - Fac Inactive for Inspection Well unchanged from last visit on 7/7/16. Gauge on 4 1/2" casing reads 70#, if it is working and valve appears open to sales line, but it is unclear if this well is producing. Well still leaks from conductor annulus below ground level.

For data sources see[7]

References