Well History

Date Event
1901-01-01 Drilling Completion
2014-09-23 OLD WELL

For data sources see[4]



Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2420818 Primary Facility 2015-04-30 Plugging(Includes Plugged/Mined Through) No Adverse Event or Action Reported Inspected location prior to Hydrocarbon moving rig onto well. Took photos.
2420914 Primary Facility 2015-06-10 Plugging(Includes Plugged/Mined Through) In Compliance with Schedule Hydrocarbon loading hole w/ fresh water, running washover shoe to clean out cement between 2 7/8" tubing and 6 5/8" casing.
2420922 Primary Facility 2015-06-11 Plugging(Includes Plugged/Mined Through) In Compliance with Schedule Hydrocarbon finished drilling down second washover shoe, clearing 40 feet of cement from between the 2 7/8" tubing and 6 5/8" casing. Will shut down until they can get casing jacks, box tap and overshot.
2420927 Primary Facility 2015-06-17 Plugging(Includes Plugged/Mined Through) In Compliance with Schedule Hydrocarbon used overshot to grab 2 7/8" tubing. Pulled tubing free w/ casing jacks and recovered ~250 feet. Tubing parted @ a bad collar. Tubing is almost completely filled w/ cement/calcite scale?
2420934 Primary Facility 2015-06-18 Plugging(Includes Plugged/Mined Through) In Compliance with Schedule Hydrocarbon TIH w/ 5 1/2" bit on tubing, set down @ 40 feet. Rigged up power swivel, repaired swivel hose. All tubing pulled so far is filled w/ calcite (?).
2420947 Primary Facility 2015-06-22 Plugging(Includes Plugged/Mined Through) In Compliance with Schedule Hydrocarbon drilling cement out of 6 5/8" casing (section that 2 7/8" tubing has been removed). Depth at time of inspection ~118 feet.
2420964 Primary Facility 2015-06-23 Plugging(Includes Plugged/Mined Through) In Compliance with Schedule Hydrocarbon drilling cement out of 6 5/8" casing, losing some circulation. Encountered a tight spot @156 feet. Drilled to 230 feet, started to mill on top of remaining 2 7/8" tubing (?).
2420969 Primary Facility 2015-06-24 Plugging(Includes Plugged/Mined Through) In Compliance with Schedule Hydrocarbon TIH w/ washover pipe, washed down 10 feet, TOOH. TIH w/ overshot, came out w/ ~ 10 feet of 2 7/8" tubing
2420974 Primary Facility 2015-06-25 Plugging(Includes Plugged/Mined Through) In Compliance with Schedule Hydrocarbon TIH w/ overshot, grabbed 2 7/8" tubing & pulled ~300 feet more tubing for a total of 541 feet so far.
2420981 Primary Facility 2015-06-30 Plugging(Includes Plugged/Mined Through) In Compliance with Schedule Hydrocarbon finished w/ washover pipe between the 2 7/8" tubing and 6 5/8" casing, TOOH, TIH w/ overshot. Will pull tubing w/ casing jacks.
2421011 Primary Facility 2015-07-08 Plugging(Includes Plugged/Mined Through) No Adverse Event or Action Reported Hydrocarbon shut down, WO smaller bit. Met w/ Susan Ghoweri at site to review activities to date, inspected tubing and packer retrieved from well.
2421082 Primary Facility 2015-07-13 Plugging(Includes Plugged/Mined Through) In Compliance with Schedule Hydrocarbon TIH w/ tubing & tricone bit to continue cleaning out hole.
2421085 Primary Facility 2015-07-14 Plugging(Includes Plugged/Mined Through) In Compliance with Schedule Hydrocarbon circulating rope fragments from hole to pit. Pulled up on tubing; pulling tight (rope settled around bit and tubing).
2421088 Primary Facility 2015-07-21 Plugging(Includes Plugged/Mined Through) In Compliance with Schedule Hydrocarbon drilled to 730 feet, lost all circulation. TOOH (wiper trip), TIH to 730 feet, re-established circulation.
2421093 Primary Facility 2015-07-22 Plugging(Includes Plugged/Mined Through) In Compliance with Schedule Met w/ Steve Jones (Hydrocarbon) on site to discuss new tool he had fabricated: tubing collar w/ hardened cross-ribs. Will use as adrill bit, will add turbulence to circulating cuttings and help move rope fragments up and out. Mud pump broke down while at depth of 730 feet.
2421096 Primary Facility 2015-07-28 Plugging(Includes Plugged/Mined Through) No Adverse Event or Action Reported Hydrocarbon delivered a replacement mud pump (waiting on parts for other pump), but it would not pump. Worked on pump.
2421100 Primary Facility 2015-07-30 Plugging(Includes Plugged/Mined Through) In Compliance with Schedule Hydrocarbon drilled down to 764 feet w/ paddle bit (photo). Pieces of rope in returns were plugging bit & hoses, so circulated, TOOH, cleaned out bit and TIH to 500 feet. Shut down, waiting on water delivery.
2421107 Primary Facility 2015-08-03 Plugging(Includes Plugged/Mined Through) In Compliance with Schedule Hydrocarbon waited on water, placed new liners in cellar and under mud pump. Finished tripping into hole w/ paddle bit, got to 720 feet.
2421113 Primary Facility 2015-08-06 Plugging(Includes Plugged/Mined Through) In Compliance with Schedule Hydrocarbon repaired blown seal on mud pump. TIH w/ mill bit to drill below 780 feet.
2421121 Primary Facility 2015-08-10 Plugging(Includes Plugged/Mined Through) In Compliance with Schedule Hydrocarbon had down-hole camera run in well, only got to 670 feet, as hole was bridged. Hole in 6 5/8" casing seen @ 211 feet.
2421124 Primary Facility 2015-08-11 Plugging(Includes Plugged/Mined Through) In Compliance with Schedule Hydrocarbon cleaned out down to 784 feet, circulating a lot of rope fragments out. Got call mid-morning from Charleroi Borough to cease operations due to funding shortfall.
2421133 Primary Facility 2015-09-11 Plugging(Includes Plugged/Mined Through) No Adverse Event or Action Reported Most of Hydrocarbon equipment remains on location since call by Charleroi Borough to cease operations on 8/11/15.
2421142 Primary Facility 2015-10-30 Plugging(Includes Plugged/Mined Through) In Compliance with Policy Hydrocarbon removed all equipment, cleaned, graded, seeded and mulched the site. Vent was installed on well.
2488805 Primary Facility 2016-05-23 Plugging(Includes Plugged/Mined Through) No Adverse Event or Action Reported Visited site to check on wellhead and vent; appeared intact.
2512314 Primary Facility 2016-08-01 Plugging(Includes Plugged/Mined Through) No Adverse Event or Action Reported Vent remains intact, no noticeable gas venting. adjacent water well (?) show water level 2-3 feet below ground level and is not bubbling. Site has become grown up w/ weeds.
2614870 Primary Facility 2017-07-12 Routine/Partial Inspection In Compliance with Policy Visited site to check vent on well. Intact, no gas noted. Site remains taped off w/ caution tape.
2682682 Primary Facility 2018-01-16 Routine/Partial Inspection No Viols - Permanently Shut Down Visited site to check status of well vent. Intact and functional, unchanged from last visit. Unable to determine if any gas was venting.
2779399 Primary Facility 2018-09-25 Routine/Partial Inspection No Viols - Permanently Shut Down Well vent remains intact and functional. Adjacent water well (?) has no water level visible.