X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-121-45028

Well Details

Well ID: 37-121-45028
Loading map...
Country: United States
State: Pennsylvania
County: Venango
Municipality: Richland Township
Operator Name: CHEVRON APPALACHIA LLC
Well Pad ID: 147213
Farm/Lease Name: BROSIUS 1H
License Status: Plugged OG Well
Spud Date: 2012-11-10
Permit Date: 2012-11-08
Unconventional Well: Y
Configuration: Horizontal Well
Latitude: 41.259472
Longitude: -79.658408

For data sources see[1][2][3]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2013-10-01 2013-10-08 4926 7,692,630.0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 GBL Clearwater Gel Breaker Ethylene Glycol 107-21-1 60 0.00007840 0
Iron Control A Nalco Iron Control Ethylene Glycol 107-21-1 30 0.0070717 0
CMHPG Ashland Water Viscosifier Carboxymethyl Hydroxporoyl Guar Blend 68130-15-4 100 0.0051357 0
Unislik ST 50 CESI Friction Reducer Hydrotreated Light Distillite 64742-47-8 30 0.000281701 0
EC 6116a Nalco Biocide Dibromoacetonitrile 3252-43-5 5 0.0012728 0
Polyethylene Glycol 25322-68-3 60 0.0152741 0
1, 1-Dibromo-3-nitrilopropionamide 10222-01-2 30 0.0076371 0
Clean Volume Chevron Applachia, LLC Carrier/Base Fluid H20 7732-18-5 100 91.31 0
15% Hcl Acid Reagent/PPG Used to open perfs Hydrochloric Acid 7647-01-0 15 0.0939818 0
Proppant US Sand Co Proppant Crystalline Silica 14808-60-7 100 8.68 0
Scale Inhibitor A Nalco Scale Inhibitor Ethylene Glycol 107-21-1 30 0.0075451 0

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2012 CHEVRON APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2013 CHEVRON APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2014 CHEVRON APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2015 CHEVRON APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2016 CHEVRON APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2017 CHEVRON APPALACHIA LLC 30,484.00 31 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 CHEVRON APPALACHIA LLC Drilling Fluid Waste (in Barrels) 4,022.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001
2012 CHEVRON APPALACHIA LLC Drill Cuttings (in Tons) 79.70 Tons LANDFILL 101397
2013 CHEVRON APPALACHIA LLC Fracing Fluid Waste (in Barrels) 1,627.50 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2013 CHEVRON APPALACHIA LLC Drilling Fluid Waste (in Barrels) 1,697.50 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001
2013 CHEVRON APPALACHIA LLC Drilling Fluid Waste (in Barrels) 10,790.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2013 CHEVRON APPALACHIA LLC Drill Cuttings (in Tons) 692.87 Tons LANDFILL 101397
2013 CHEVRON APPALACHIA LLC Drilling Fluid Waste (in Barrels) 300.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 CHEVRON APPALACHIA LLC Fracing Fluid Waste (in Barrels) 14,865.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2014 CHEVRON APPALACHIA LLC Drill Cuttings (in Tons) 2.60 Tons LANDFILL 100419
2014 CHEVRON APPALACHIA LLC Fracturing Fluid Waste (in Tons) 53.40 Tons STORAGE PENDING DISPOSAL OR REUSE MID0209062814
2014 CHEVRON APPALACHIA LLC Drill Cuttings (in Tons) 4.18 Tons LANDFILL 100585
2014 CHEVRON APPALACHIA LLC Fracing Fluid Waste (in Barrels) 28,629.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 CHEVRON APPALACHIA LLC Fracturing Fluid Waste (in Tons) 59.66 Tons LANDFILL 100585
2014 CHEVRON APPALACHIA LLC Drill Cuttings (in Tons) 882.13 Tons LANDFILL 101397

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2115653 Primary Facility 2012-11-13 Drilling/Alteration Violation(s) Noted
2115679 Primary Facility 2012-11-13 Drilling/Alteration No Violations Noted
2119904 Primary Facility 2012-11-29 Drilling/Alteration No Violations Noted
2125733 Primary Facility 2012-12-18 Routine/Complete Inspection No Violations Noted
2133337 Primary Facility 2013-01-24 Drilling/Alteration No Violations Noted
2135544 Primary Facility 2013-01-30 Routine/Complete Inspection No Violations Noted
2150171 Primary Facility 2013-03-21 Routine/Complete Inspection No Violations Noted
2167864 Primary Facility 2013-05-20 Routine/Complete Inspection No Violations Noted
2179958 Primary Facility 2013-07-02 Routine/Complete Inspection No Violations Noted
2183749 Primary Facility 2013-07-10 Routine/Complete Inspection No Violations Noted
2200885 Primary Facility 2013-09-03 Drilling/Alteration No Violations Noted
2211405 Primary Facility 2013-10-03 Drilling/Alteration Violation(s) Noted
2228883 Primary Facility 2013-12-12 Routine/Complete Inspection No Violations Noted
2235807 Primary Facility 2014-01-09 Routine/Complete Inspection No Violations Noted
2259786 Primary Facility 2014-04-01 Routine/Complete Inspection No Violations Noted
2269048 Primary Facility 2014-05-06 Routine/Complete Inspection Violation(s) Noted
2269088 Primary Facility 2014-05-06 Routine/Complete Inspection No Violations Noted
2272923 Primary Facility 2014-05-20 Administrative/File Review No Violations Noted
2276715 Primary Facility 2014-06-03 Administrative/File Review No Violations Noted
2277878 Primary Facility 2014-06-10 Routine/Partial Inspection No Violations Noted
2341935 Primary Facility 2015-02-09 Administrative/File Review No Violations Noted
2424729 Primary Facility 2015-11-10 Site Restoration No Violations Noted
2659170 Primary Facility 2017-11-08 Routine/Partial Inspection No Violations Noted Records show RINAC 7/18/14. Received notice from the operator that an intent to inspect the well for Inactive was scheduled for 1pm on 11/8/17. Received notice from Chevron's representative that he was delayed. Requested results be sent to me by email.

Note: Request received on 11/12/17 (attached).

2801794 Primary Facility 2018-11-13 Plugging(Includes Plugged/Mined Through) No Violations Noted Inspected location, crew is currently rigging up BOP then the rig will move over hole, once rig is up cementing operations are going to begin.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2211405 679943 10/03/2013 2013-10-03 601.101 - O&G Act 223-General. Used only when a specific O&G Act code cannot be used Administrative 3211(f)(2)
2269048 695304 05/06/2014 2014-05-06 OGA 3220(A) - Failure to plug the well upon abandoning it. Environmental Health & Safety

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
679943 303456 NOV - Notice of Violation Comply/Closed 2014-05-06