X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-117-21906

Well Details

Well ID: 37-117-21906
Loading map...
Country: United States
State: Pennsylvania
County: Tioga
Municipality: Liberty Township
Operator Name: SWN PROD CO LLC
Well Pad ID: 152994
Farm/Lease Name: BLISS 1H
License Status:
Spud Date:
Permit Date: 2017-05-15
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.581509
Longitude: -77.101076

For data sources see[1][2][3]

Well History

Date Event
2017-05-15 New Permit Application
2017-08-15 Performed Spud Operation
2017-10-02 MOD

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2018-04-07 2018-04-23 7,085 13,201,500 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Ingredients Listed Above Listed Above Water 7732-18-5 100 0.737811 908365
HYDROCHLORIC ACID Halliburton Solvent Listed Below Listed Below 0 0 0
FR-76 Halliburton Friction Reducer Listed Below Listed Below 0 0 0
BE-9W Halliburton Biocide Listed Below Listed Below 0 0 0
Diammonium phosphate 7783-28-0 5 0.0010582 1303
Hydrochloric acid 7647-01-0 15 0.0927231 114158
Crystalline silica, quartz 14808-60-7 100 11.1688 13,750,600.0
Fatty acid ester Proprietary 5 0.00411355 5066
Hydrotreated light petroleum distillate 64742-47-8 30 0.0204491 25177
Inorganic salt Proprietary 30 0.0204491 25177
Sodium chloride 7647-14-5 5 0.00205677 2533
Organic phosphonate Proprietary 60 0.0126984 15634
Ethoxyalted fatty acid Proprietary 5 0.00205677 2533
Hydroteated light petroleum distillate 64742-47-8 30 0.0123406 15194
Ammonium chloride 12125-02-9 30 0.00840599 10350
Non-hazardous food substance Proprietary 100 0.000407746 502
Tributyl tetradecyl phosphonium chloride 81741-28-8 10 0.00413759 5095
Polyacrylate Proprietary 30 0.0123406 15194
Acrylamide acrylate copolymer Proprietary 30 0.0204491 25177
Propylene glycol 57-55-6 60 0.0248255 30565
SAND-COMMON WHITE-100 MESH, SSA-2, BULK (100003676) Halliburton Proppant Listed Below Listed Below 0 0 0
Fresh Water Operator Base Fluid Water 7732-18-5 100 88.0408 108,392,000.0
SAND-PREMIUM WHITE-30/50, BULK Halliburton Proppant Listed Below Listed Below 0 0 0
LP-65 MC Halliburton Scale Inhibitor Listed Below Listed Below 0 0 0
HAI-150E Halliburton Corrosion Inhibitor Listed Below Listed Below 0 0 0
EXCELERATE LX-1 Halliburton Friction Reducer Listed Below Listed Below 0 0 0

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2017 SWN PROD CO LLC 0.00 0 0.00 0 0.00 0
2018 SWN PROD CO LLC 3,765,520.00 230 0.00 0 0.00 0
2019 SWN PROD CO LLC 3,072,455.00 354 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2017 SWN PROD CO LLC Other Oil & Gas Wastes 208.90 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2017 SWN PROD CO LLC Other Oil & Gas Wastes 1,815.75 Bbl REUSE (AT WELL PAD)
2017 SWN PROD CO LLC Drilling Fluid Waste 310.00 Bbl REUSE (AT WELL PAD)
2017 SWN PROD CO LLC Other Oil & Gas Wastes 55.00 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017 SWN PROD CO LLC Soil Contaminated by Oil 0.81 Tons LANDFILL 301358
2017 SWN PROD CO LLC Drill Cuttings 1,434.57 Tons LANDFILL 301626
2017 SWN PROD CO LLC Drill Cuttings 15.57 Tons LANDFILL 301358
2017 SWN PROD CO LLC Drilling Fluid Waste 1,140.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2017 SWN PROD CO LLC Soil Contaminated by Oil & Gas Related Spills 0.81 Tons LANDFILL 301358
2017 SWN PROD CO LLC Synthetic Liner Materials 17.71 Tons LANDFILL 101247
2017 SWN PROD CO LLC Drilling Fluid Waste 480.00 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017 SWN PROD CO LLC Drill Cuttings 182.42 Tons LANDFILL 101247
2018 SWN PROD CO LLC Produced Fluid 240.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2018 SWN PROD CO LLC Other Oil & Gas Wastes 460.00 Bbl REUSE (AT WELL PAD)
2018 SWN PROD CO LLC Produced Fluid 10,006.50 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018 SWN PROD CO LLC Other Oil & Gas Wastes 275.42 Bbl SURFACE IMPOUNDMENT 826342
2018 SWN PROD CO LLC Produced Fluid 16,730.00 Bbl REUSE (AT WELL PAD)
2018 SWN PROD CO LLC Filter Socks 0.25 Tons RESIDUAL WASTE PROCESSING FACILITY 301333
2018 SWN PROD CO LLC Other Oil & Gas Wastes 110.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018 SWN PROD CO LLC Synthetic Liner Materials 137.53 Tons LANDFILL 301358
2018 SWN PROD CO LLC Produced Fluid 9,845.00 Bbl SURFACE IMPOUNDMENT 826342
2018 SWN PROD CO LLC Produced Fluid 74.77 Tons LANDFILL 301358
2018 SWN PROD CO LLC Other Oil & Gas Wastes 1,102.50 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018 SWN PROD CO LLC Waste Water Treatment Sludge 11.73 Tons LANDFILL 301358
2018 SWN PROD CO LLC Unused Fracturing Fluid Waste 118.42 Tons LANDFILL 301358
2018 SWN PROD CO LLC Other Oil & Gas Wastes 50.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2019 SWN PROD CO LLC Produced Fluid 55.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC035
2019 SWN PROD CO LLC Waste Water Treatment Sludge 8.48 Tons RESIDUAL WASTE PROCESSING FACILITY 2014-541
2019 SWN PROD CO LLC Produced Fluid 1,470.00 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019 SWN PROD CO LLC Produced Fluid 55.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2019 SWN PROD CO LLC Synthetic Liner Materials 3.49 Tons LANDFILL 301358
2019 SWN PROD CO LLC Other Oil & Gas Wastes 110.00 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019 SWN PROD CO LLC Produced Fluid 302.50 Bbl REUSE (AT WELL PAD)
2019 SWN PROD CO LLC Produced Fluid 55.00 Bbl SURFACE IMPOUNDMENT 826342
2019 SWN PROD CO LLC Synthetic Liner Materials 3.12 Tons LANDFILL 100933

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2575546 Primary Facility 2017-03-27 Routine/Complete Inspection No Violations Noted Inspection to assess overall site conditions. Stone has been placed on the entire surface of the well pad. No violations were cited.
2615227 Primary Facility 2017-07-14 Preoperation Inspection No Violations Noted Pre-operational inspection conducted at the request of Southwestern Energy. All perimeter BMPs are installed, and the site has been constructed as designed and permitted. No violations cited.
2649344 Primary Facility 2017-10-18 Drilling/Alteration No Violations Noted Conductor only.
2654849 Primary Facility 2017-10-27 Routine/Complete Inspection No Violations Noted I met Jonathan Woodburn on-site. SWN rig # 45 running production casing in the 5H well. Cuttings processing was idle. Containments appeared to be in good condition. The site was somewhat muddy, and Woody told me he had a vac truck scheduled to clean things up.
2725605 Primary Facility 2018-05-01 Routine/Complete Inspection No Violations Noted I met Joe Forker, SWN company man when I arrived. A workover rig was on the site, and had been drilling out plugs on the 1H well; when I arrived, the rig was tripping out of the well. Joe informed me that they would be deploying fishing tools into the well to recover some live perf guns that were lost in the 8th stage. Joe walked the site with me. A 50-70 gallon puddle on the pad in a high traffic area had slightly elevated conductivity 2.36 mS/cm); all other puddles on the pad were significantly lower (.3- .9 mS/cm). I recommended to Joe that he have it vacced, and while I was still on the site Joe directed a vac truck driver to move to the puddle and clean it up. The containment and berms seemed to be in good condition.
2773048 Primary Facility 2018-09-04 Site Restoration No Violations Noted Site restoration inspection with Sara Metz and Mike Jurbala (DEP). A SWN employee was leaving the site as we arrived and requested that we lock the gate when we were finished.

Two of five permitted wells (Bliss 5H and 1H) have been drilled and stimulated. At the time of the inspection, it appeared that the wells were either still in the process of or had recently finished being flowed back.

This inspection was conducted in response to submittal of a post-drilling well site restoration report. The site is stable with vegetative cover exceeding 70%. PCSM has been addressed through installation of a bioretention basin that appears to be functioning as designed. The site has been permitted to remain at full pad size. At this time, due to the presence of the temporary storage tank battery, the associated tank battery secondary containment, and the secondary containment around the wells themselves, the site does not yet meet all of the post-drilling site restoration criteria under 78a.65. I recommend returning t

2842733 Primary Facility 2019-02-21 Routine/Complete Inspection No Violations Noted Weather was 40 degrees and sunny. Met with Southwestern representative Andrew Griffith. Well was in production. Well was covered with an orange steel cage due to drilling activities on location. Well had gas monitoring equipment to detect any presence of combustable gas during drilling activities. Well had one annulus vent (9x5) plumbed to surface and closed in at time of inspection. No violations were noted at time of equipment.
2845448 Primary Facility 2019-02-26 Routine/Complete Inspection No Violations Noted SDC 44 rig on location. I met Andrew Griffith of SWN on the site; rig was running casing in the 4H well, and Andrew told me the rig would be skidding to the 6H well on the evening of 2/26. Sitewide and secondary containments and berms appeared to be in good condition, and the cuttings processing area and backyard were clean and well maintained. Chemical storage areas were clean as well. Andrew informed me that they were using dual-fuel air packs which are capable of diesel and natural gas blended up to 70% diesel. Most of the air packs were not in use while I was on the site.
2852993 Primary Facility 2019-03-13 Routine/Complete Inspection No Violations Noted Weather was 30 degrees and sunny. Met with Southwestern representative Dan Hessdorfer on location. Well was in production. Well was covered with an orange steel cage due to drilling activities on location. Well had gas monitoring equipment to detect any presence of combustable gas during drilling activities. Well had one annulus vent (9x5) plumbed to surface and closed in at time of inspection. No violations were noted at time of equipment.

For data sources see[8]

References