If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-117-21874 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.573283,"lon":-77.130574,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Tioga | |
Municipality: Liberty Township | |
Operator Name: SWN PROD CO LLC | |
Well Pad ID: 152514 | |
Farm/Lease Name: CONNOLLY A 8H | |
License Status: | |
Spud Date: | |
Permit Date: 2016-11-30 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.573283 | |
Longitude: -77.130574 |
Date | Event |
---|---|
2016-11-30 | New Permit Application |
2016-12-15 | Performed Spud Operation |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2018-06-03 | 2018-06-21 | 7,112 | 10,081,700 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | SAND-COMMON WHITE-100 MESH, SSA-2, BULK (100003676) | Halliburton | Proppant | Listed Below | Listed Below | 0 | 0 | 0 |
HYDROCHLORIC ACID | Halliburton | Solvent | Listed Below | Listed Below | 0 | 0 | 0 | |
EXCELERATE LX-1 | Halliburton | Friction Reducer | Listed Below | Listed Below | 0 | 0 | 0 | |
BE-9 | Halliburton | Biocide | Listed Below | Listed Below | 0 | 0 | 0 | |
HAI-150E | Halliburton | Corrosion Inhibitor | Listed Below | Listed Below | 0 | 0 | 0 | |
Ingredients | Listed Above | Listed Above | Water | 7732-18-5 | 100 | 1.84881 | 1,724,690.0 | |
Tributyl tetradecyl phosphonium chloride | 81741-28-8 | 10 | 0.00236062 | 2203 | ||||
Polyacrylate | Proprietary | 30 | 0.0259808 | 24237 | ||||
Hydrochloric acid | 7647-01-0 | 15 | 0.263062 | 245402 | ||||
Fatty acid ester | Proprietary | 5 | 0.00866028 | 8080 | ||||
Diammonium phosphate | 7783-28-0 | 5 | 0.00162441 | 1516 | ||||
Ethoxyalted fatty acid | Proprietary | 5 | 0.00433014 | 4040 | ||||
Hydroteated light petroleum distillate | 64742-47-8 | 30 | 0.0259808 | 24237 | ||||
Non-hazardous food substance | Proprietary | 100 | 0.000535983 | 500 | ||||
Sodium chloride | 7647-14-5 | 5 | 0.00433014 | 4040 | ||||
Ammonium chloride | 12125-02-9 | 30 | 0.0140766 | 13133 | ||||
Organic phosphonate | Proprietary | 60 | 0.019493 | 18185 | ||||
Crystalline silica, quartz | 14808-60-7 | 100 | 12.078 | 11,267,100.0 | ||||
Fresh Water | Operator | Base Fluid | Water | 7732-18-5 | 100 | 86.0251 | 80,249,800.0 | |
SAND-PREMIUM WHITE-30/50, BULK | Halliburton | Proppant | Listed Below | Listed Below | 0 | 0 | 0 | |
LP-65 MC | Halliburton | Scale Inhibitor | Listed Below | Listed Below | 0 | 0 | 0 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2016 | SWN PROD CO LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2017 | SWN PROD CO LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2018 | SWN PROD CO LLC | 1,644,861.00 | 164 | 0.00 | 0 | 0.00 | 0 |
2019 | SWN PROD CO LLC | 1,614,437.00 | 365 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2016 | SWN PROD CO LLC | Drill Cuttings | 24.38 Tons | LANDFILL | 101247 |
2016 | SWN PROD CO LLC | Drill Cuttings | 57.39 Tons | LANDFILL | 301358 |
2017 | SWN PROD CO LLC | Other Oil & Gas Wastes | 126.00 Bbl | REUSE (AT WELL PAD) | |
2017 | SWN PROD CO LLC | Other Oil & Gas Wastes | 12.50 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2017 | SWN PROD CO LLC | Drilling Fluid Waste | 9.50 Bbl | REUSE (AT WELL PAD) | |
2017 | SWN PROD CO LLC | Drill Cuttings | 172.21 Tons | LANDFILL | 301358 |
2018 | SWN PROD CO LLC | Produced Fluid | 183.33 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2018 | SWN PROD CO LLC | Other Oil & Gas Wastes | 67.94 Bbl | SURFACE IMPOUNDMENT | 826342 |
2018 | SWN PROD CO LLC | Unused Fracturing Fluid Waste | 3.04 Tons | LANDFILL | 100933 |
2018 | SWN PROD CO LLC | Other Oil & Gas Wastes | 1,330.00 Bbl | REUSE (AT WELL PAD) | |
2018 | SWN PROD CO LLC | Produced Fluid | 29.58 Tons | LANDFILL | 301358 |
2018 | SWN PROD CO LLC | Produced Fluid | 36,142.66 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2018 | SWN PROD CO LLC | Produced Fluid | 23,918.66 Bbl | SURFACE IMPOUNDMENT | 826342 |
2018 | SWN PROD CO LLC | Produced Fluid | 10,636.67 Bbl | REUSE (AT WELL PAD) | |
2018 | SWN PROD CO LLC | Produced Fluid | 233.34 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2018 | SWN PROD CO LLC | Other Oil & Gas Wastes | 90.34 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2018 | SWN PROD CO LLC | Other Oil & Gas Wastes | 36.67 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2018 | SWN PROD CO LLC | Other Oil & Gas Wastes | 36.67 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2018 | SWN PROD CO LLC | Filter Socks | 0.20 Tons | RESIDUAL WASTE PROCESSING FACILITY | 301333 |
2019 | SWN PROD CO LLC | Drill Cuttings | 231.63 Tons | LANDFILL | 101247 |
2019 | SWN PROD CO LLC | Other Oil & Gas Wastes | 80.00 Bbl | SURFACE IMPOUNDMENT | 826342 |
2019 | SWN PROD CO LLC | Produced Fluid | 8,323.35 Bbl | REUSE (AT WELL PAD) | |
2019 | SWN PROD CO LLC | Produced Fluid | 2,080.01 Bbl | SURFACE IMPOUNDMENT | 826342 |
2019 | SWN PROD CO LLC | Waste Water Treatment Sludge | 2.60 Tons | RESIDUAL WASTE PROCESSING FACILITY | 2014-541 |
2019 | SWN PROD CO LLC | Produced Fluid | 8,029.98 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2019 | SWN PROD CO LLC | Produced Fluid | 1,766.67 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC035 |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2551740 | Primary Facility | 2017-01-12 | Drilling/Alteration | No Violations Noted | |
2566155 | Primary Facility | 2017-03-01 | Routine/Complete Inspection | No Violations Noted | Drilling operations underway. Darin Hall of SWN on site. No sheens or evidence of spills or leaks observed outside of secondary containment. No violations cited. |
2569720 | Primary Facility | 2017-03-09 | Routine/Complete Inspection | No Violations Noted | Inspection conducted to assess site conditions after drilling operations. As noted in the previous inspection, temporary E&S control BMPs are in place and no evidence of accelerated erosion or sedimentation was observed. No evidence of any spills, such as odors, sheens, or stains was observed on the pad surface. No violations were cited during this inspection. |
2588207 | Primary Facility | 2017-04-27 | Routine/Complete Inspection | No Violations Noted | |
2724865 | Primary Facility | 2018-05-01 | Routine/Complete Inspection | No Violations Noted | Weather was 61° and sunny at time of inspection. Well was shut in and covered by a large orange steel cage at time of inspection. There were no,pressure gauges attached to the well at time of inspection. There was one annulus vent plumbed to surface that was shut in at time of inspection. No violations noted at time of inspection. |
2725584 | Primary Facility | 2018-05-01 | Routine/Complete Inspection | No Violations Noted | No activity on the pad when I arrived. Pipeline work at entrance and across the road. Containment was partially dismantled, with some of the rig mats removed and stacked, as well as some berms removed and stacked. Puddles on the well pad showed low conductance (.9 -1.6 mS/cm). The 8H well cellar was nearly full to the top with water; I recommend that it be vacced ASAP. Site looked good overall. |
2738666 | Primary Facility | 2018-06-05 | Routine/Complete Inspection | No Violations Noted | I met Will Stevens of SWN in the command trailer when I arrived. Frac was active (Halliburton), although it was pressured down for a move from the 7H to the 8H well. I was joined on my inspection by Jeremy Eichenberger and Allen Green of SWN. The site and sitewide containment were very clean, with no standing water. I did note in 3 locations (near the sand boxes, near the production tanks, and near the GPUs) where the sitewide liner had fallen or been blown off of the Jersey barriers forming the berms, and pointed these out to Jeremy and Allen. The issue seemed to be that the liner had not been installed long enough to reach the ground on the backside of the Jersey barriers; Jeremy and Allen proposed seaming an additional piece of liner to the existing liner to allow the liner to reach the ground so it could be secured with sandbags to keep it in place. |
2773340 | Primary Facility | 2018-09-04 | Routine/Complete Inspection | No Violations Noted | Southwestern Energy (SWN) submitted a well site restoration report to the Department for SWN TI-14-Connolly A Pad on 8/22/18.
Department staff Mike Jurbala, Sara Metz, and Sasha Minium conducted a site restoration inspection at the above site on 9/4/18. Two SWN employees remained in their vehicles during the inspection. There are 3 Marcellus wells staged for production on the pad (Connolly A 2H, 7H, &8H). The wells were in secondary containment and the well cellars were covered by the containment. There are 3 GPUs and 1 production water tank within secondary containment. The site meets 70% uniform, perennial, vegetative cover. All PCSMs have been installed as depicted on PCSM/SR plans. However, at the time of inspection flowback water tanks remained on site. As per 78a.65(a)(1) these tanks, their associated secondary containment, the secondary containment around the wells and any other equipment or containment not needed for production should be removed as part of the site restoration plan. I recommend r |
2811135 | Primary Facility | 2018-12-06 | Routine/Complete Inspection | No Violations Noted | Weather was 30° and cloudy at time of inspection. There were no Southwestern representatives on location at time of inspection. Well had digital pressure monitoring equipment on the production tubing. Production tubing pressure was 349 psi at time of inspection. There was one annulus vent plumbed to surface. It was plumbed into the pay line. 0% combustible gas was detected in any area surrounding the wellhead at time of inspection. No violations were noted at time of inspection. |
For data sources see[8]