Well Details

Well ID: 37-117-21659
Loading map...
Country: United States
State: Pennsylvania
County: Tioga
Municipality: Clymer Township
Operator Name: SWEPI LP
Well Pad ID: 150139
Farm/Lease Name: SHARRETTS 805 23H
License Status:
Spud Date:
Permit Date: 2013-08-21
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: Yes
Latitude: 41.828983
Longitude: -77.503225

For data sources see[1][2][3]

Well History

Date Event
2013-08-21 New Permit Application
2013-08-26 Performed Spud Operation
2014-01-25 Drilling Completion
2014-02-10 Perforation
2015-01-05 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2014-06-27 2014-06-28 11,782 3,540,670 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 SAND - PREMIUM WHITE Halliburton Proppant Crystalline silica, quartz 14808-60-7 100 9.98001 3,431,080.0
HYDROCHLORIC ACID 10-30% Halliburton Solvent Hydrochloric acid 7647-01-0 30 0.164374 56511
FE-1A ACIDIZING COMPOSITION Halliburton Iron Control Acetic anhydride 108-24-7 100 0.00273712 942
Acetic acid 64-19-7 60 0.00164227 565
Fresh Water Operator Base Fluid Fresh Water 7732-18-5 100 85.8914 29,529,000.0
SSA-2 Halliburton Proppant Crystalline silica, quartz 14808-60-7 100 3.4844 1,197,920.0
HAI-OS ACID INHIBITOR Halliburton Corrosion Inhibitor Propargyl alcohol 107-19-7 10 0.00004526 16
Methanol 67-56-1 60 0.000271575 94
Other Ingredient(s) Organic phosphonate Confidential 0 0.00867924 2984
Alcohols, C14-C15, ethoxylated 68951-67-7 0 0.000135787 47
Fatty alcohol polyglycol ether surfactant 9043-30-5 0 0.00004101 15
Crystalline silica, quartz 14808-60-7 0 0.00000410 2
Sorbitan monooleate polyoxyethylene derivative 9005-65-6 0 0.00054586 188
Ammonium chloride 12125-02-9 0 0.0027293 939
Fatty acid tall oil amide Confidential 0 0.0027293 939
Alcohols, C12-16, ethoxylated 68551-12-2 0 0.0027293 939
Polyacrylamide copolymer Confidential 0 0.0163758 5630
Quaternary ammonium compounds,
bis(hydrogenated tallow alkyl)
dimethyl,salts with bentonite
68953-58-2 0 0.000205063 71
Reaction product of acetophenone,
formaldehyde, thiourea
and oleic acid in dimethyl formamide
68527-49-1 0 0.000135787 47
Formaldehyde 50-00-0 0 0.000144654 50
Sodium sulfate 7757-82-6 0 0.00000005 1
Fatty acids, tall oil Confidential 0 0.000135787 47
Water 7732-18-5 0 0.609199 209440
Olefins Confidential 0 0.00000453 2
Sorbitan, mono-9-octadecenoate, (Z) 1338-43-8 0 0.00054586 188
Olefins Confidential 0 0.00002263 8
Sodium chloride 7647-14-5 0 0.0027293 939
BE-9 Halliburton Biocide Tributyl tetradecyl phosphonium chloride 81741-28-8 10 0.00198563 683
FR-66 Halliburton Friction Reducer Hydrotreated light petroleum distillate 64742-47-8 30 0.0163758 5630
LGC-36 UC Halliburton Liquid Gel Concentrate Naphtha, hydrotreated heavy 64742-48-9 60 0.00246075 846
Guar gum 9000-30-0 60 0.00246075 846
LP-65MC Halliburton Scale Inhibitor Ammonium chloride 12125-02-9 10 0.00144654 498
SP BREAKER Halliburton Breaker Sodium persulfate 7775-27-1 100 0.00005119 18

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2013 SWEPI LP 0.00 0 0.00 0 0.00 0
2014 SWEPI LP 0.00 0 0.00 0 0.00 0
2015 SWEPI LP 2,079,054.88 340 0.00 0 0.00 0
2016 SWEPI LP 762,640.77 350 0.00 0 0.00 0
2017 SWEPI LP 524,301.30 360 0.00 0 0.00 0
2018 SWEPI LP 291,235.28 358 0.00 0 0.00 0
2019 SWEPI LP 203,164.97 292 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2013 SWEPI LP Fracing Fluid Waste 100.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 SWEPI LP Drilling Fluid Waste 535.33 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2013 SWEPI LP Drilling Fluid Waste 188.81 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2013 SWEPI LP Drilling Fluid Waste 265.49 Bbl REUSE OTHER THAN ROAD SPREADING
2013 SWEPI LP Drill Cuttings 414.69 Tons LANDFILL 301358
2014 SWEPI LP Fracing Fluid Waste 1,032.96 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2014 SWEPI LP Fracing Fluid Waste 1,627.32 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2014 SWEPI LP Fracing Fluid Waste 2,379.92 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2014 SWEPI LP Drilling Fluid Waste 2,754.80 Bbl REUSE OTHER THAN ROAD SPREADING
2014 SWEPI LP Fracing Fluid Waste 1,891.61 Bbl REUSE OTHER THAN ROAD SPREADING
2014 SWEPI LP Drill Cuttings 411.97 Tons LANDFILL 301358
2015 SWEPI LP Produced Fluid 36.67 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2015 SWEPI LP Produced Fluid 440.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2015 SWEPI LP Produced Fluid 9.36 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WVD988782532
2015 SWEPI LP Produced Fluid 2,294.83 Bbl REUSE OTHER THAN ROAD SPREADING
2016 SWEPI LP Waste Water Treatment Sludge 3.77 Tons RESIDUAL WASTE PROCESSING FACILITY WMGR123
2016 SWEPI LP Produced Fluid 2,991.11 Bbl REUSE OTHER THAN ROAD SPREADING
2017 SWEPI LP Waste Water Treatment Sludge 0.94 Tons RESIDUAL WASTE PROCESSING FACILITY WMGR123
2017 SWEPI LP Produced Fluid 1,585.97 Bbl REUSE (AT WELL PAD)
2017 SWEPI LP Produced Fluid 102.33 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2018 SWEPI LP Produced Fluid 233.33 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2018 SWEPI LP Produced Fluid 586.33 Bbl REUSE (AT WELL PAD)
2018 SWEPI LP Produced Fluid 167.46 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018 SWEPI LP Other Oil & Gas Wastes 92.49 Bbl RESIDUAL WASTE TRANSFER FACILITY 7-3115-00193
2018 SWEPI LP Produced Fluid 17.33 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2019 SWEPI LP Produced Fluid 99.56 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2019 SWEPI LP Produced Fluid 33.33 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2019 SWEPI LP Servicing Fluid 319.13 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2019 SWEPI LP Servicing Fluid 55.29 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2019 SWEPI LP Produced Fluid 408.01 Bbl REUSE (AT WELL PAD)
2019 SWEPI LP Other Oil & Gas Wastes 1.99 Bbl RESIDUAL WASTE TRANSFER FACILITY 7-3115-00193

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2207668 Primary Facility 2013-09-26 Routine/Partial Inspection No Violations Noted On Sept 26, 2013 a routine partial inspection was conducted at the Sharretts 805 pad in Clymer Township, Tioga County. The last inspection conducted on behalf of the operator was on 9/26/2013. The 2H and 2HB wells have been drilled and a third well (23H) has recently been spudded. During this inspection the site was being re-graded in preparation for additional drilling in the coming weeks. The cut slope above the pad is in need of further stabilization. Some sediment transport to the rock-lined ditched was observed, but nothing has left the site. No violations were cited during this inspection.
2209372 Primary Facility 2013-10-01 Routine/Complete Inspection No Violations Noted
2238439 Primary Facility 2014-01-21 Drilling/Alteration No Violations Noted
2244667 Primary Facility 2014-02-11 Compliance Evaluation Violation(s) Noted puddle on pad 19 mS/cm. 3 wells drilled on this site
2265508 Primary Facility 2014-04-25 Compliance Evaluation No Violations Noted On April 25, 2014 a compliance evaluation inspection was conducted at the Sharretts 805 pad in Clymer Township, Tioga County. The purpose of this inspection was to follow up on the progress of the operator in response to a Notice of Violation (307537) issued following a Feb. 12, 2014 inspection (2244667). The impacted soil has been excavated and disposed of properly. A summary report outlining the soil remediation and post-excavation was submitted by the operator (see permit file). No puddles of elevated conductivity were observed during today's inspection. The violations noted in 2/12/ 14 inspection report are resolved. No violation cited during this inspection.
2284492 Primary Facility 2014-07-07 Drilling/Alteration No Violations Noted
2450856 Primary Facility 2016-02-18 Routine/Complete Inspection No Violations Noted The Department of Environmental Protection (DEP) inspected the SWEPI LP – Sharretts 805 site located in Clymer Twp., Tioga Co. on 2/18/2016 @ 1230 hours. An adequate site ID sign was observed at the entrance to the access road. A copy of the E&S plan, well permits and PPC plan was located in the mailbox onsite. The onsite inspection log showed the site as last being inspected by company personnel on 2/17/2016 with the comments “site snow covered”. The receiving waters are listed as UNT to Jemison Creek HQ-CWF, MF.

Contracted personnel appeared to be doing maintenance work on production equipment during the inspeciton. All E&S BMPs are snow covered, but appeared to be functional. No violations were noted during this inspection. I departed the site @ 1330 hours. Please contact me with any questions.

2557333 Primary Facility 2017-02-01 Routine/Complete Inspection No Violations Noted The Department of Environmental Protection (DEP) inspected the SWEPI LP Sharretts well site on 1/1/2017. The weather was 30?with heavy snow showers. All inspected secondary containment was full of snow. Erosion and sediment controls could not be observed due to snow. Site last inspected by company personnel on January 28 with "no changes" recorded in the comment section. No violations were noted during this inspection.
2581952 Primary Facility 2017-04-12 Routine/Complete Inspection No Violations Noted The DEP inspected the SWEPI LP Sharretts 805 well site in Clymer Twp. Tioga Co. on 4/12/2017 @ 1030 hours. The weather was sunny 56 degrees. The inspection was conducted to check the status of newly installed post construction Stormwater management BMV's. Some erosion and failure of ECB matting was noted. Please see attached pictures. The erosion does not appear to have been noted in the on-site E&S inspection log. Most newly restored areas appear to be stabilized by approximately 40% vegetative cover. No puddles were observed on the pad surface. No fluid was observed and secondary containment. Please Address any deficiencies noted, and contact me with any questions. I departed the site at 1130 hours.
2638337 Primary Facility 2017-09-19 Site Restoration No Violations Noted Restoration inspection conducted on 9/19/17. The Well Site Restoration Report (WSRR) and Notice of Termination (NOT) were received on 9/18/17. Interim restoration has been completed, post construction stormwater management BMPs installed, temporary E&S controls removed and the site permanently stabilized. The WSRR was acknowledged on 9/19/17 and the NOT on 9/21/17. TLT

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2244667 688697 02/11/2014 2014-02-11 SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. Environmental Health & Safety
2244667 688715 02/11/2014 2014-02-11 402CSL - Failure to adopt pollution prevention measures required or prescribed by DEP by handling materials that create a danger of pollution. Environmental Health & Safety
2244667 688716 02/11/2014 2014-02-11 78.54* - Failure to properly control or dispose of industrial or residual waste to prevent pollution of the waters of the Commonwealth. Environmental Health & Safety

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
688697 307537 NOV - Notice of Violation Comply/Closed 2014-04-25
688715 307537 NOV - Notice of Violation Comply/Closed 2014-04-25
688716 307537 NOV - Notice of Violation Comply/Closed 2014-04-25

For data sources see[8]