37-117-21548

Well Details

Well ID: 37-117-21548
Loading map...
Country: United States
State: Pennsylvania
County: Tioga
Municipality: Liberty Township
Operator Name: ROCKDALE MARCELLUS LLC
Well Pad ID: 149411
Farm/Lease Name: TAYLOR M 718W 1H
License Status:
Spud Date:
Permit Date: 2012-06-28
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.561003
Longitude: -77.069314

For data sources see[1][2][3]

Well History

Date Event
2012-06-28 New Permit Application
2012-07-07 Performed Spud Operation
2013-12-04 Drilling Completion
2014-01-29 Perforation
2014-07-25 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2014-02-27 2014-03-06 6,716 5,412,750 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1
Sand (Proppant), DAP-902, DAP-925,
DWP-602, BioClear 2000, Hydrochloric Acid
CWS Propping Agent, Scale Inhibitor, Acid Corrosion Inhibitor, Friction Reducer, Biocide, Clean Perforations Polyacrylamide polymer Proprietary 40 0.03024 15799.8
Calcite 471-34-1 1 0.01373 7173.66
Apatite 64476-38-6 0.1 0.00719 3755.38
Methanol 67-56-1 60 0.00011 55.36
Nonionic surfactant Proprietary 5 0.00378 1974.98
Polyoxyalkylenes surfactant Proprietary 5 0.00378 1974.98
Illite 12173-60-3 1 0.01764 9217.21
Propargyl Alcohol 107-19-7 10 0.00002000 9.23
Polyoxyalkylenes Proprietary 30 0.00005000 27.68
Ilmenite 98072-94-7 0.1 0.00653 3413.78
Olefin Proprietary 5 0.00001000 4.61
Sodium chloride 7647-14-5 1 0.00001000 0.92
Polyethylene glycol mixture 25322-68-3 70 0.01229 6423.18
Biotite 1302-27-8 0.1 0.00719 3755.38
Hydrochloric acid 7647-01-0 37 0.15232 79589.2
Paraffinic hydrocarbon solvent 64742-47-8 30 0.02268 11849.9
Organic acid salts Proprietary 40 0.00611 3190.55
1,2-Propanediol 57-55-6 10 0.00153 797.64
Modified thiourea polymer 68527-49-1 30 0.00005000 27.68
Crystalline silica (Quartz) 14808-60-7 100 12.9903 6,787,470.0
Formaldehyde 50-00-0 0.1 0.00001000 0.09
2,2-Dibromo-3-Nitrilopropionamide 10222-01-2 40 0.01229 6423.18
Goethite 1310-14-1 0.1 0.00849 4438.59
Fatty acids Proprietary 30 0.00005000 27.68
Water Customer & CWS Base Fluid & Mix Water Water 7732-18-5 100 86.7036 45,302,800.0

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2012 SWEPI LP 0.00 0 0.00 0 0.00 0
2013 SWEPI LP 0.00 0 0.00 0 0.00 0
2014 SWEPI LP 1,169,367.28 246 0.00 0 0.00 0
2015 SWEPI LP 964,322.48 358 0.00 0 0.00 0
2016 SWEPI LP 752,639.48 363 0.00 0 0.00 0
2017 SWEPI LP 619,371.29 360 0.00 0 0.00 0
2018 ROCKDALE MARCELLUS LLC 412,967.00 365 0.00 0 0.00 0
2019 ROCKDALE MARCELLUS LLC 225,372.69 304 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 SWEPI LP Drilling Fluid Waste 150.71 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123
2012 SWEPI LP Fracing Fluid Waste 47.96 Bbl REUSE OTHER THAN ROAD SPREADING
2012 SWEPI LP Fracing Fluid Waste 58.88 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123
2013 SWEPI LP Drilling Fluid Waste 478.04 Bbl REUSE OTHER THAN ROAD SPREADING
2013 SWEPI LP Drilling Fluid Waste 145.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2013 SWEPI LP Fracing Fluid Waste 35.71 Bbl REUSE OTHER THAN ROAD SPREADING
2013 SWEPI LP Drill Cuttings 463.84 Tons LANDFILL 301358
2014 SWEPI LP Fracing Fluid Waste 645.20 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2014 SWEPI LP Fracing Fluid Waste 196.56 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2014 SWEPI LP Drilling Fluid Waste 1,121.45 Bbl REUSE OTHER THAN ROAD SPREADING
2014 SWEPI LP Fracing Fluid Waste 7,131.85 Bbl REUSE OTHER THAN ROAD SPREADING
2014 SWEPI LP Produced Fluid 13,922.34 Bbl REUSE OTHER THAN ROAD SPREADING
2014 SWEPI LP Produced Fluid 2,801.28 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2014 SWEPI LP Produced Fluid 247.51 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2014 SWEPI LP Drill Cuttings 282.59 Tons LANDFILL 301358
2015 SWEPI LP Produced Fluid 129.11 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2015 SWEPI LP Produced Fluid 66.66 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC011
2015 SWEPI LP Produced Fluid 3,183.33 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2015 SWEPI LP Fracing Fluid Waste 18.33 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2015 SWEPI LP Produced Fluid 5,937.66 Bbl REUSE OTHER THAN ROAD SPREADING
2016 SWEPI LP Synthetic Liner Materials 0.53 Tons LANDFILL 301358
2016 SWEPI LP Produced Fluid 45.24 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2016 SWEPI LP Produced Fluid 3,390.00 Bbl REUSE OTHER THAN ROAD SPREADING
2017 SWEPI LP Produced Fluid 88.06 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2017 SWEPI LP Waste Water Treatment Sludge 8.70 Tons STORAGE PENDING DISPOSAL OR REUSE PA-0678
2017 SWEPI LP Produced Fluid 2,282.08 Bbl REUSE (AT WELL PAD)
2017 SWEPI LP Produced Fluid 715.31 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2018 ROCKDALE MARCELLUS LLC Other Oil & Gas Wastes 36.67 Bbl REUSE (AT WELL PAD)
2018 ROCKDALE MARCELLUS LLC Produced Fluid 947.34 Bbl REUSE (AT WELL PAD)
2018 ROCKDALE MARCELLUS LLC Produced Fluid 74.67 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR119
2018 ROCKDALE MARCELLUS LLC Produced Fluid 863.32 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018 ROCKDALE MARCELLUS LLC Produced Fluid 246.38 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2019 ROCKDALE MARCELLUS LLC Produced Fluid 56.67 Bbl STORAGE PENDING DISPOSAL OR REUSE WMGR123NC036
2019 ROCKDALE MARCELLUS LLC Other Oil & Gas Wastes 30.00 Bbl STORAGE PENDING DISPOSAL OR REUSE WMGR123NC036
2019 ROCKDALE MARCELLUS LLC Produced Fluid 36.67 Bbl REUSE (AT WELL PAD)

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2113424 Primary Facility 2012-10-24 Routine/Complete Inspection No Violations Noted 1V drilled, 1-6H drilled vertical
2228532 Primary Facility 2013-12-10 Incident- Response to Accident or Event No Violations Noted 3bbl spill of drilling mud onto containment while on 3H well. TLT
2228837 Primary Facility 2013-12-11 Routine/Complete Inspection No Violations Noted
2251587 Primary Facility 2014-03-04 Incident- Response to Accident or Event Pending 5-10 gal spill of produced fluid. Insp result pending sample results. TLT
2254920 Primary Facility 2014-03-18 Routine/Complete Inspection No Violations Noted
2257441 Primary Facility 2014-03-25 Administrative/File Review Viol(s) Noted & Immediately Corrected
2277232 Primary Facility 2014-06-09 Follow-up Inspection No Violations Noted
2433194 Primary Facility 2015-12-15 Routine/Complete Inspection No Violations Noted Routine inspection to assess site conditions. Weather was overcast, breezy, and about 45 degrees. No SWEPI representatives were present.
2484312 Primary Facility 2016-05-05 Routine/Complete Inspection No Violations Noted
2557514 Primary Facility 2017-02-01 Routine/Complete Inspection No Violations Noted Routine inspection to assess overall site conditions.

No evidence of accelerated erosion or sedimentation was observed. Vegetative cover was obscured due to snow.

No violations were cited during this inspection.

2718290 Primary Facility 2018-04-12 Routine/Complete Inspection No Violations Noted Weather was 42° and cloudy at time of inspection. There were no Rockdale representatives on location at time of inspection. Well had one analog pressure gauge attached above the swab valve. The pressure gauge attached above the swab valve read approximately 500 psi at time of inspection. There were three annulus vents plumbed to surface. Unable to determine the origin point of each individual annulus vent due to the cellar being full of dirt. Based off other wells of similar design, the 5 1/2" x 9 5/8" (2" pipe) annulus had 5% methane detected at time of inspection. The other 2 vents, 1 1/2" and 1", had 0% combustible gas detected at time of inspection. No violations noted at time of inspection.
2841000 Primary Facility 2019-02-14 Routine/Complete Inspection No Violations Noted Routine inspection conducted to assess overall site conditions. Site was snow-covered at the time of inspection. Three wells are staged for production. Well tags on well heads say SWEPI instead of Rockdale. The Department recommends replacing the well tags. One produced water tank is present within steel containment with plastic lining. There is heavy corrosion in one area of the produced water tank. The produced water tank does not have a permanent label. The Department recommends replacing the label on the produced water tank. Two GPUs are present and in good condition.

No violations noted.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2257441 691968 03/25/2014 2014-03-25 78.54* - Failure to properly control or dispose of industrial or residual waste to prevent pollution of the waters of the Commonwealth. Environmental Health & Safety 78.54 for failure to control/dispose of fluids in accordance with Sections 78.55 - 78.58. 5-10 gallon spill of production fluid to containment and subsequently onto the ground. TLT
2257441 691969 03/25/2014 2014-03-25 SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. Environmental Health & Safety 6018.301 of the Solid Waste Management Act for allowing an unpermitted discharge of residual waste onto the ground. 5-10 gallon spill of production fluid to containment and subsequently onto the ground. TLT
2257441 691970 03/25/2014 2014-03-25 OGA3218.2(A) - Failure to design and construct unconventional well site to prevent spills to the ground surface and off well site. Environmental Health & Safety 3218.2(a) of the Oil & Gas Act for failure to maintain containment to prevent spills to the ground surface. 5-10 gallon spill of production fluid to containment and subsequently onto the ground. TLT

For data sources see[8]