X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-117-21394

Well Details

Well ID: 37-117-21394
Loading map...
Country: United States
State: Pennsylvania
County: Tioga
Municipality: Charleston Township
Operator Name: SWEPI LP
Well Pad ID: 147877
Farm/Lease Name: BURKE T 285N 2H
License Status: Plugged and Abandoned
Spud Date: 2011-12-23
Permit Date: 2011-12-08
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.7811
Longitude: -77.223756

For data sources see[1][2][3]

Well History

Date Event
Newly Drilled
2011-12-08 New Permit Application
2011-12-19 Performed Spud Operation
2011-12-23 Drilling Completion
2018-12-13 Begin Plugging
2018-12-13 Finished Plugging
2019-03-12 Fully Plugged

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2011 SWEPI LP 0.00 0 0.00 0 0.00 0
2012 SWEPI LP 0.00 0 0.00 0 0.00 0
2013 SWEPI LP 0.00 0 0.00 0 0.00 0
2014 SWEPI LP 0.00 0 0.00 0 0.00 0
2015 SWEPI LP 0.00 0 0.00 0 0.00 0
2016 SWEPI LP 0.00 0 0.00 0 0.00 0
2017 SWEPI LP 0.00 0 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 SWEPI LP Drill Cuttings 260.92 Tons LANDFILL 9312
2018 SWEPI LP Produced Fluid 300.75 Bbl REUSE (AT WELL PAD)

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2110010 Primary Facility 2012-10-22 Routine/Complete Inspection No Violations Noted
2406725 Primary Facility 2015-09-14 Routine/Complete Inspection No Violations Noted
2479666 Primary Facility 2016-04-25 Complaint Inspection No Violations Noted Complaint inspection. The 5H & 6H wells were being plugged at time of complaint. The 5H and 6H wells were spud on 12/8/11 (80' of conductor pipe installed), however never drilled. A stained area was noted on pad surface. Staining was grayish-brown in color. SWEPI stated that cellar water and surface water which had accumulated in the conductor pipe was discharged to pad surface to infiltrate. Staining on pad was surficial. Requested that SWEPI evaluate stained area and determine whether remedial actions are necessary. TLT
2496289 Primary Facility 2016-06-28 Routine/Complete Inspection No Violations Noted
2560967 Primary Facility 2017-02-10 Routine/Partial Inspection No Violations Noted Partial inspection. Site idle and snow covered. 1H - 4H have been partially drilled to depth of 2030' (according to Well Record Reports). The 5H & 6H wells were plugged in April 2016. The 1V well was placed on inactive status on 5/9/14. SWEPI's two-year restoration extension request was approved on 5/4/16. A new ESCGP2 application is currently under review. Permanent stablization and E&S controls were not observed due to the snow cover. No violations were cited during the inspection. TLT
2602982 Primary Facility 2017-06-06 Routine/Partial Inspection No Violations Noted Puddle on pad 0.18 mS/cm w an Oakton PCSTestr 35. Onsite ~1415-1510.
2779452 Primary Facility 2018-09-25 Routine/Complete Inspection No Violations Noted Routine (pre-plugging) inspection of 4 wells on the pad which are "top-holed"; surface/intermediate casings installed and cemented, cemented shoe track in 9 5/8" casing, and no openhole below the casing shoe. It was reported no oil or gas zones were encountered. At the time of inspection, all four wells had cellars full of gravel. Wells are capped. Annular vents were present. No gas was detected at the vents or in the gravel next to well caps. Also on location is the recently plugged 1V well which is cut and buried. There were no open holes, discharges, venting, or any other obvious issues observed on location during this inspection.
2792089 Primary Facility 2018-10-22 Routine/Complete Inspection No Violations Noted Cool/windy at tome of inspection.
2815344 Primary Facility 2018-12-13 Plugging(Includes Plugged/Mined Through) No Violations Noted A routine (plugging) inspection on the Burke pad was conducted December 13, 2018. I spoke with the plugging contractor on location, who is in the process of plugging the four remaining wells on the pad; the 1H, 2H, 3H, and 4H. All four wells are "topholed"; surface/intermediate casings were set and cemented upon drilling, the 9 5/8" has a ~80' cemented shoe track below float valve, and no open hole below the 9 5/8" casing shoe. The contractor is onsite to fill the inside of the casing to surface with gravel to satisfy the regulatory requirements of plugging a non-coal well. No obvious issues or concerns were observed at this time.
2815350 Primary Facility 2018-12-13 Plugging(Includes Plugged/Mined Through) No Violations Noted A routine (plugging) inspection on the Burke pad was conducted December 13, 2018. I spoke with the plugging contractor on location, who is in the process of plugging the four remaining wells on the pad; the 1H, 2H, 3H, and 4H. All four wells are "topholed"; surface/intermediate casings were set and cemented upon drilling, the 9 5/8" has a ~80' cemented shoe track below float valve, and no open hole below the 9 5/8" casing shoe. The contractor is onsite to fill the inside of the casing to surface with gravel to satisfy the regulatory requirements of plugging a non-coal well. No obvious issues or concerns were observed at this time.
2819271 Primary Facility 2018-12-26 Plugging(Includes Plugged/Mined Through) No Violations Noted A routine (post-plugging) inspection of four vertical uncompleted wells was conducted December 26, 2018. All equipment and personnel are off location following the final plug and abandonment of the 1H, 2H, 3H, and 4H. The wells are now cut below grade, marked, and buried. No gas was detected in the gravel above the buried well locations. No open holes, discharges, venting, or other obvious issues were observed at this time.

For data sources see[7]

References