X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-117-21295

Well Details

Well ID: 37-117-21295
Loading map...
Country: United States
State: Pennsylvania
County: Tioga
Municipality: Blossburg Borough
Operator Name: SENECA RESOURCES CO LLC
Well Pad ID: 148214
Farm/Lease Name: DCNR 595 PAD E 12H 50181
License Status:
Spud Date:
Permit Date: 2011-07-22
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.687692
Longitude: -77.078933

For data sources see[1][2][3]

Well History

Date Event
2011-07-22 New Permit Application
2011-08-23 Performed Spud Operation
2012-01-18 Drilling Completion
2012-05-02 Perforation
2012-12-13 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2012-06-06 2012-06-06 7,903 6,821,598

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Proppant 30/50 Ottawa Universal Well Services Proppant Quartz 14808-60-7 100.00 4.74
Iron Stabilizer II Universal Well Services Corrosion Inhibitor Ethylene glycol 107-21-1 30.00 0.00044000
ScaleHib 100 Universal Well Services Scale Inhibitor Ethylene glycol 107-21-1 60.00 0.00864000
GB L Universal Well Services Breaker Ethylene glycol 107-21-1 60.00 0.00
Unihib G Universal Well Services Corrosion Inhibitor Ethoxylated Alcohol 35.00 0.00013000
Diethylene glycol monobutyl ether 112-34-5 50.00 0.00019000
Resin Based Nonionic Inhibitor 35.00 0.00013000
7.5 HydroChloric Acid Universal Well Services Acid Hydrochloric acid 7647-01-0 7.50 0.06
Proppant 40/70 Ottawa Universal Well Services Proppant Quartz 14808-60-7 100.00 4.83
Proppant 80/100 Oklahoma Universal Well Services Proppant Quartz 14808-60-7 100.00 0.22
Unislik ST 50 Universal Well Services Friction Reducer Distillates, petroleum, hydrotreated light 64742-47-8 30.00 0.02
BioRid 20L Tetra Biocide Sodium bromide 7647-15-6 15.00 0.00205000
2,2-Dibromo-3-nitrilopropionamide 10222-01-2 20.00 0.00273000
Unigel 5F Universal Well Services Guar Gel Dry Add Guar Gum 100.00 0.00008000
15 HydroChloric Acid Universal Well Services Acid Hydrochloric acid 7647-01-0 15.00 0.00961000

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2011 SENECA RESOURCES CO LLC 0.00 0 0.00 0 0.00 0
2012 SENECA RESOURCES CO LLC 866,590.00 169 0.00 0 0.00 0
2013 SENECA RESOURCES CO LLC 1,456,534.00 365 0.00 0 0.00 0
2014 SENECA RESOURCES CO LLC 994,492.70 335 0.00 0 0.00 0
2015 SENECA RESOURCES CO LLC 347,275.78 88 0.00 0 0.00 0
2016 SENECA RESOURCES CO LLC 502,527.51 138 0.00 0 0.00 0
2017 SENECA RESOURCES CO LLC 830,511.65 359 0.00 0 0.00 0
2018 SENECA RESOURCES CO LLC 591,744.21 353 0.00 0 0.00 0
2019 SENECA RESOURCES CO LLC 495,153.89 361 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2011 SENECA RESOURCES CO LLC Drill Cuttings 739.85 Tons LANDFILL 301358
2012 SENECA RESOURCES CO LLC Produced Fluid 887.00 Bbl INJECTION DISPOSAL WELL 34-155-21447
2012 SENECA RESOURCES CO LLC Produced Fluid 455.00 Bbl INJECTION DISPOSAL WELL 34-133-20525
2012 SENECA RESOURCES CO LLC Produced Fluid 132.00 Bbl INJECTION DISPOSAL WELL 34-155-21893
2012 SENECA RESOURCES CO LLC Produced Fluid 238.00 Bbl INJECTION DISPOSAL WELL 34-155-23795
2012 SENECA RESOURCES CO LLC Produced Fluid 907.00 Bbl INJECTION DISPOSAL WELL 34-155-21438
2012 SENECA RESOURCES CO LLC Produced Fluid 10,648.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 SENECA RESOURCES CO LLC Produced Fluid 20.00 Bbl INJECTION DISPOSAL WELL 34-083-24072
2012 SENECA RESOURCES CO LLC Produced Fluid 133.00 Bbl INJECTION DISPOSAL WELL 34-155-23203
2012 SENECA RESOURCES CO LLC Produced Fluid 60.00 Bbl INJECTION DISPOSAL WELL 34-151-23420
2012 SENECA RESOURCES CO LLC Drill Cuttings 531.43 Tons LANDFILL 301358
2012 SENECA RESOURCES CO LLC Fracing Fluid Waste 102.00 Bbl INJECTION DISPOSAL WELL 34-155-23584
2012 SENECA RESOURCES CO LLC Fracturing Fluid Waste 1.58 Tons LANDFILL 301358
2012 SENECA RESOURCES CO LLC Fracing Fluid Waste 4,473.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 SENECA RESOURCES CO LLC Produced Fluid 133.00 Bbl INJECTION DISPOSAL WELL 34-155-21894
2013 SENECA RESOURCES CO LLC Produced Fluid 2,266.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 SENECA RESOURCES CO LLC Produced Fluid 20.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NC012
2013 SENECA RESOURCES CO LLC Produced Fluid 60.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC012
2014 SENECA RESOURCES CO LLC Produced Fluid 511.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015 SENECA RESOURCES CO LLC Fracing Fluid Waste 40.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2015 SENECA RESOURCES CO LLC Produced Fluid 25.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW011
2015 SENECA RESOURCES CO LLC Produced Fluid 347.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 SENECA RESOURCES CO LLC Produced Fluid 90.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2016 SENECA RESOURCES CO LLC Produced Fluid 141.17 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW011
2017 SENECA RESOURCES CO LLC Produced Fluid 253.25 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2017 SENECA RESOURCES CO LLC Other Oil & Gas Wastes 19.17 Bbl REUSE (AT WELL PAD)
2017 SENECA RESOURCES CO LLC Produced Fluid 473.01 Bbl REUSE (AT WELL PAD)
2018 SENECA RESOURCES CO LLC Produced Fluid 245.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018 SENECA RESOURCES CO LLC Other Oil & Gas Wastes 18.33 Bbl REUSE (AT WELL PAD)
2018 SENECA RESOURCES CO LLC Produced Fluid 322.51 Bbl REUSE (AT WELL PAD)
2019 SENECA RESOURCES CO LLC Produced Fluid 84.17 Bbl RESIDUAL WASTE TRANSFER FACILITY WMGR123NC039
2019 SENECA RESOURCES CO LLC Produced Fluid 149.19 Bbl REUSE (AT WELL PAD)
2019 SENECA RESOURCES CO LLC Produced Fluid 171.68 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2009855 Primary Facility 2011-10-11 Routine/Complete Inspection No Violations Noted access road sediment runoff into state forest. viols charged to 13H
2068545 Primary Facility 2012-05-16 Follow-up Inspection No Violations Noted closing E&S viols. fracking 6 gas wells
2073985 Primary Facility 2012-06-01 Compliance Evaluation No Violations Noted frackin, 10 brl frack fluid release from valve under pressure
2253292 Primary Facility 2014-03-11 Incident- Response to Accident or Event No Violations Noted Production liquid leaked out behind separators when flange developed hole. Violations cited to escgp
2312583 Primary Facility 2014-10-14 Follow-up Inspection No Violations Noted Clossing violations from 11 MAR 2014, when production liquid leaked out of flow line.
2592675 Primary Facility 2017-05-03 Routine/Partial Inspection No Violations Noted This is an inspection of DCNR 595 Pad E.

Electrical conductivity readings w an Oakton PCSTestr 35: production tank containment--0.13 mS/cm, separator containment--0.15 mS/cm, pad--1.2 mS/cm. Onsite during this inspection were 2 Seneca workers tending to the separators. The basin down gradient of the pad (photo) is not on the plan drawing. The basin along the access road (photo) is listed as a "rain garden" on the plan. Time: ~1500-1555 hrs

2820642 Primary Facility 2018-12-28 Site Restoration No Violations Noted This inspection covers DCNR 595 Pad E (not Pads C & G).

NOT denied. Slopes around the pad are temporarily stabilized with hydroseed and sparse vegetation (photo 2). Filter sock (photo 1) is considered a temporary E & S control and hydro seed temporary stabilization; ESCGP termination requires "permanent stabilization", and removal of temporary E & S controls. I took electrical conductivity readings from pooled water on site with an Oakton PCSTestr 35. A puddle near the production tanks returned 0.17 mS/cm. Air temp: 45F JLP

For data sources see[8]

References