37-117-21294

Well Details

Well ID: 37-117-21294
Loading map...
Country: United States
State: Pennsylvania
County: Tioga
Municipality: Blossburg Borough
Operator Name: SENECA RESOURCES CO LLC
Well Pad ID: 148214
Farm/Lease Name: DCNR 595 PAD E 11H 50180
License Status:
Spud Date:
Permit Date: 2011-07-22
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.687772
Longitude: -77.078933

For data sources see[1][2][3]

Well History

Date Event
2011-07-22 New Permit Application
2011-08-23 Performed Spud Operation
2011-12-28 Drilling Completion
2012-05-02 Perforation
2012-12-13 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2012-05-27 2012-05-27 7,875 7,707,084

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Unislik ST 50 Universal Well Services Friction Reducer Distillates, petroleum, hydrotreated light 64742-47-8 30.00 0.02
Proppant 30/50 Ottawa Universal Well Services Proppant Quartz 14808-60-7 100.00 4.36
BioRid 20L Tetra Biocide Sodium bromide 7647-15-6 15.00 0.00178000
2,2-Dibromo-3-nitrilopropionamide 10222-01-2 20.00 0.00237000
Unihib G Universal Well Services Corrosion Inhibitor Diethylene glycol monobutyl ether 112-34-5 50.00 0.00015000
Resin Based Nonionic Inhibitor 35.00 0.00010000
Ethoxylated Alcohol 35.00 0.00010000
15 HydroChloric Acid Universal Well Services Acid Hydrochloric acid 7647-01-0 15.00 0.00842000
ScaleHib 100 Universal Well Services Scale Inhibitor Ethylene glycol 107-21-1 60.00 0.00781000
7.5 HydroChloric Acid Universal Well Services Acid Hydrochloric acid 7647-01-0 7.50 0.04
Proppant 40/70 Ottawa Universal Well Services Proppant Quartz 14808-60-7 100.00 4.39
CFT-1200 Core Laboratories Chemical Tracer Water 7732-18-5 90.00 0.00005000
Proprietary Ingredient supplied as 10 w/v Aqueous Solution 10.00 0.00001000
CFT-1900 Core Laboratories Chemical Tracer Water 7732-18-5 90.00 0.00013000
Proprietary Ingredient supplied as 10 w/v Aqueous Solution 10.00 0.00001000
Iron Stabilizer II Universal Well Services Corrosion Inhibitor Ethylene glycol 107-21-1 30.00 0.00034000
CFT-2000 Core Laboratories Chemical Tracer Proprietary Ingredient supplied as 10 w/v Aqueous Solution 10.00 0.00001000
Water 7732-18-5 90.00 0.00010000
CFT-1600 Core Laboratories Chemical Tracer Water 7732-18-5 90.00 0.00011000
Proprietary Ingredient supplied as 10 w/v Aqueous Solution 10.00 0.00001000
CFT-2400 Core Laboratories Chemical Tracer Water 7732-18-5 90.00 0.00006000
Proprietary Ingredient supplied as 10 w/v Aqueous Solution 10.00 0.00001000
CFT-1300 Core Laboratories Chemical Tracer Water 7732-18-5 90.00 0.00009000
Proprietary Ingredient supplied as 10 w/v Aqueous Solution 10.00 0.00001000
Proppant 80/100 Oklahoma Universal Well Services Proppant Quartz 14808-60-7 100.00 0.18

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2011 SENECA RESOURCES CO LLC 0.00 0 0.00 0 0.00 0
2012 SENECA RESOURCES CO LLC 977,701.00 167 0.00 0 0.00 0
2013 SENECA RESOURCES CO LLC 1,758,227.00 365 0.00 0 0.00 0
2014 SENECA RESOURCES CO LLC 1,211,268.60 347 0.00 0 0.00 0
2015 SENECA RESOURCES CO LLC 473,012.68 124 0.00 0 0.00 0
2016 SENECA RESOURCES CO LLC 1,153,324.26 366 0.00 0 0.00 0
2017 SENECA RESOURCES CO LLC 777,075.17 362 0.00 0 0.00 0
2018 SENECA RESOURCES CO LLC 619,777.16 364 0.00 0 0.00 0
2019 SENECA RESOURCES CO LLC 524,439.50 362 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2011 SENECA RESOURCES CO LLC Drill Cuttings 1,529.17 Tons LANDFILL 301358
2012 SENECA RESOURCES CO LLC Produced Fluid 1,430.00 Bbl INJECTION DISPOSAL WELL 34-155-21447
2012 SENECA RESOURCES CO LLC Produced Fluid 17,104.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 SENECA RESOURCES CO LLC Produced Fluid 214.00 Bbl INJECTION DISPOSAL WELL 34-155-21893
2012 SENECA RESOURCES CO LLC Fracturing Fluid Waste 1.57 Tons LANDFILL 301358
2012 SENECA RESOURCES CO LLC Produced Fluid 32.00 Bbl INJECTION DISPOSAL WELL 34-083-24072
2012 SENECA RESOURCES CO LLC Fracing Fluid Waste 3,330.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 SENECA RESOURCES CO LLC Produced Fluid 214.00 Bbl INJECTION DISPOSAL WELL 34-155-21894
2012 SENECA RESOURCES CO LLC Produced Fluid 214.00 Bbl INJECTION DISPOSAL WELL 34-155-23203
2012 SENECA RESOURCES CO LLC Produced Fluid 384.00 Bbl INJECTION DISPOSAL WELL 34-155-23795
2012 SENECA RESOURCES CO LLC Produced Fluid 96.00 Bbl INJECTION DISPOSAL WELL 34-151-23420
2012 SENECA RESOURCES CO LLC Drill Cuttings 28.06 Tons LANDFILL 301358
2012 SENECA RESOURCES CO LLC Produced Fluid 1,462.00 Bbl INJECTION DISPOSAL WELL 34-155-21438
2012 SENECA RESOURCES CO LLC Fracing Fluid Waste 834.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123
2012 SENECA RESOURCES CO LLC Produced Fluid 734.00 Bbl INJECTION DISPOSAL WELL 34-133-20525
2013 SENECA RESOURCES CO LLC Produced Fluid 1,773.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 SENECA RESOURCES CO LLC Produced Fluid 15.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NC012
2013 SENECA RESOURCES CO LLC Produced Fluid 84.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC012
2014 SENECA RESOURCES CO LLC Produced Fluid 116.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015 SENECA RESOURCES CO LLC Produced Fluid 358.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW011
2015 SENECA RESOURCES CO LLC Fracing Fluid Waste 40.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2015 SENECA RESOURCES CO LLC Produced Fluid 441.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 SENECA RESOURCES CO LLC Produced Fluid 90.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2016 SENECA RESOURCES CO LLC Produced Fluid 140.17 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW011
2017 SENECA RESOURCES CO LLC Produced Fluid 252.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2017 SENECA RESOURCES CO LLC Other Oil & Gas Wastes 19.17 Bbl REUSE (AT WELL PAD)
2017 SENECA RESOURCES CO LLC Produced Fluid 473.26 Bbl REUSE (AT WELL PAD)
2018 SENECA RESOURCES CO LLC Produced Fluid 245.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018 SENECA RESOURCES CO LLC Other Oil & Gas Wastes 18.33 Bbl REUSE (AT WELL PAD)
2018 SENECA RESOURCES CO LLC Produced Fluid 319.18 Bbl REUSE (AT WELL PAD)
2019 SENECA RESOURCES CO LLC Produced Fluid 149.19 Bbl REUSE (AT WELL PAD)
2019 SENECA RESOURCES CO LLC Produced Fluid 84.17 Bbl RESIDUAL WASTE TRANSFER FACILITY WMGR123NC039
2019 SENECA RESOURCES CO LLC Produced Fluid 171.68 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2009854 Primary Facility 2011-10-11 Routine/Complete Inspection No Violations Noted access road sediment runoff into state forest. viols charged to 13H
2068548 Primary Facility 2012-05-16 Follow-up Inspection No Violations Noted closing E&S viols. fracking 6 gas wells
2073984 Primary Facility 2012-06-01 Compliance Evaluation No Violations Noted frackin, 10 brl frack fluid release from valve under pressure
2253291 Primary Facility 2014-03-11 Incident- Response to Accident or Event No Violations Noted Production liquid leaked out behind separators when flange developed hole. Violations cited to escgp
2312580 Primary Facility 2014-10-14 Follow-up Inspection No Violations Noted Clossing violations from 11 MAR 2014, when production liquid leaked out of flow line.
2592668 Primary Facility 2017-05-03 Routine/Partial Inspection No Violations Noted This is an inspection of DCNR 595 Pad E.

Electrical conductivity readings w an Oakton PCSTestr 35: production tank containment--0.13 mS/cm, separator containment--0.15 mS/cm, pad--1.2 mS/cm. Onsite during this inspection were 2 Seneca workers tending to the separators. The basin down gradient of the pad (photo) is not on the plan drawing. The basin along the access road (photo) is listed as a "rain garden" on the plan. Time: ~1500-1555 hrs

2820640 Primary Facility 2018-12-28 Site Restoration No Violations Noted This inspection covers DCNR 595 Pad E (not Pads C & G).

NOT denied. Slopes around the pad are temporarily stabilized with hydroseed and sparse vegetation (photo 2). Filter sock (photo 1) is considered a temporary E & S control and hydro seed temporary stabilization; ESCGP termination requires "permanent stabilization", and removal of temporary E & S controls. I took electrical conductivity readings from pooled water on site with an Oakton PCSTestr 35. A puddle near the production tanks returned 0.17 mS/cm. Air temp: 45F JLP

For data sources see[8]